1 dari 1

Omron V680-HS51 V680 Series Cylindrical Antenna

Omron V680-HS51 V680 Series Cylindrical Antenna

Hanya 7 item tersisa di stok
  • Produsen: Omron

  • Nomor Produk: V680-HS51

  • Negara asal:Jepang

  • Jenis Produk: RFID Read Write Antennas

  • Pembayaran: T/T, Western Union

  • Berat: 1000g

  • Dimensi: 160 mm x 160 mm x 60 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed for industrial radio-frequency identification systems, this Omron V680-HS51 electromagnetic inductive read/write head provides high-reliability non-contact data transmission within heavy-duty manufacturing environments. Operating at the standard high-frequency band, this industrial RFID antenna features an M12 cylindrical housing that allows for compact, space-restricted installation directly on automated machinery. The unit comes equipped with an integrated 2-meter high-flexibility coaxial connection cable, ensuring robust signal integrity and resistance to mechanical wear during continuous operation. With its oil-resistant engineering-grade construction, the device is optimized for harsh shop floors, conveyor lines, and CNC machining centers requiring rapid, accurate workpiece and tool identification.

Features

  • M12 Cylindrical Form Factor: Threaded metal barrel design allows for precise depth adjustment and space-saving mounting.
  • Integrated Connection Cable: Built-in 2-meter low-attenuation cable ensures direct connection to compatible controller/amplifier units.
  • Rugged Environmental Sealing: Rated to IP67 and IP67G (JIS C 0920 oil-resistant) standards for operation in wet or coolant-heavy environments.
  • High Noise Immunity: Advanced shielding design minimizes interference from surrounding industrial motors and power distribution networks.
  • Broad Thermal Envelope: Reliable performance from -10 degC up to 60 degC with no icing or performance degradation.

Applications

  • Automated Workpiece Tracking: Real-time identification of assembly carriers and pallets on conveyor lines.
  • CNC Tool Management: Automatic tracking and inventory management of tooling assemblies on machining spindles.
  • Intralogistics and AGVs: Position mapping and routing validation for automated guided vehicles.
  • Automotive Assembly Lines: Component tracking throughout welding, painting, and powertrain assembly processes.

Technical Specifications Table

Parameter / Specification Value / Rating
Manufacturer Omron Corporation
Model Number V680-HS51
Series V680 Industrial RFID System
Form Factor Cylindrical, M12 x 1.0 Threaded
Operating Frequency 13.56 MHz
Cable Length 2 meters
Ambient Operating Temperature -10 degC to 60 degC (with no icing)
Ambient Storage Temperature -25 degC to 75 degC (with no icing)
Insulation Resistance 20 MOhm minimum (at 500 VDC) between cable terminals and case
Shock Resistance 1000 m/s² (approx. 100G) in X, Y, and Z directions (3 times each, 18 total)
Vibration Resistance 10 to 2000 Hz, 1.5-mm double amplitude at 150 m/s² acceleration, 10 sweeps in X, Y, and Z directions for 15 minutes each
Degree of Protection IP67 (IEC 60529), IP67G (JIS C 0920 oil-resistant)
Compatible Tag Models V680-D1KPxx, V680-D2KFxx (depending on application range requirements)
Shipping Weight (Calculated) 1.0 kg
Package Dimensions (Calculated) 160 mm x 160 mm x 60 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The V680-HS51 is the highly compact M12 threaded member of the V680 antenna family. For applications requiring larger read/write ranges, specify the M18-threaded V680-HS52 or the square V680-HS63. This antenna interfaces seamlessly with standard V680 controller modules (such as the V680-CA5D01-V2) and device net/Ethernet interfaces via the V680-HA11A amplifier. Ensure compatibility of tag memory sizes (1k-byte vs. 2k-byte/32k-byte Fram tags) as performance distances depend directly on the antenna-tag combination.

Application Pitfalls & Engineering Notes

When embedding the M12 antenna head into metallic brackets, a strictly non-metallic surrounding area is required to prevent detuning of the internal coil. Mounting this antenna flush in ferrous metals without the proper radial clearance (minimum 10 mm recommended) will alter the resonant frequency, severely dropping the read/write communication range. Additionally, do not pull or stress the junction point between the cylindrical head and the cable sheath during installation to maintain water and oil-tight integrity.

Commissioning & Wiring Tips

To eliminate electromagnetic coupling and communication dropouts, route the 2-meter antenna coaxial cable away from high-power AC motor drives, servo supply lines, and 480V distribution conduits. If the application demands dynamic movement, do not bend the cable below its minimum dynamic bending radius of 30 mm. Secure the antenna thread using the provided brass nuts, ensuring torque does not exceed 10 N-m to avoid stripping or cracking the internal housing.

Installation Guidelines

CRITICAL SAFETY WARNING

Disconnect all power from the RFID controller/amplifier system before connecting or disconnecting the antenna coaxial cable. Hot-plugging the antenna can cause inductive voltage spikes that may permanently damage the sensitive RF frontend of the controller or degrade the antenna's internal matching network.

1
Prepare the Mounting Location: Drill and tap a suitable M12 aperture or prepare a 12.5 mm through-hole in a non-magnetic structural support plate. Maintain a metal-free clearance zone around the antenna head as outlined in the commissioning notes.
2
Position and Secure: Thread the V680-HS51 into position. Apply the provided mounting nuts, ensuring the active face of the antenna is correctly aligned with the tag's path of travel. Tighten to a maximum torque of 10 N-m.
3
Route the Coaxial Cable: Lay the integrated 2-meter cable through dedicated low-voltage wire trays. Secure using soft cable ties without pinching or compressing the insulation, ensuring dynamic bending constraints are strictly observed.
4
Finalize Connections: Insert the dedicated coaxial connector into the target V680 series amplifier or controller port, ensuring the connection is fully seated and the threaded lock ring is securely tightened hand-tight.
Loading product navigation…

Can the V680-HS51 antenna be mounted directly in metallic structures?

Yes, but direct contact with metallic surfaces will detune the high-frequency antenna and decrease read/write distances. To prevent signal loss, maintain a minimum radial metal-free clearance zone of 10 mm around the active sensing face.

What is the environmental ingress protection rating of this unit?

This cylindrical antenna features an IP67 and IP67G (JIS C 0920 oil-resistant) rating. It is fully protected against dust ingress, water immersion up to 1 meter, and typical industrial machine coolants and lubricants.

What is the maximum torque rating for the mounting threads of this antenna?

When mounting the V680-HS51 via its M12 threaded brass body, the maximum tightening torque applied to the mounting nuts must not exceed 10 N-m to prevent damage to the internal electronics.

Can the 2-meter integrated cable be spliced or extended?

Modifying, splicing, or extending the high-frequency coaxial cable is not recommended. This alters the cable capacitance and impedes RF matching, which will result in transmission errors and reduced read range.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jepang

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...