Description

Integrating serial Modbus connectivity directly into Allen-Bradley 1794 FLEX I/O systems is efficiently achieved using the MVI94-MCM communication module. Designed to function as a bridge between the Modbus protocol and the Rockwell Automation backplane, this module enables a host processor to interface seamlessly with field telemetry devices, SCADA systems, instruments, and PLC-based networks. The MVI94-MCM operates as either a Modbus Master or a Modbus Slave, offering versatile network configuration options for complex industrial systems.

The module occupies a single slot in the 1794 backplane and provides a reliable communication link using serial communication. It features optical isolation to protect sensitive control equipment from electrical noise and ground loop hazards. System configuration and maintenance are simplified through a dedicated, hardware-handshaking serial port, while application communications are handled via a jumper-selectable secondary port.

Features

  • FLEX I/O Compatibility: Installs directly into any standard Allen-Bradley 1794 backplane slot.
  • Dual-Port Architecture: Provides a dedicated serial configuration port (PRT1) and a multi-protocol serial application port (PRT2).
  • Protocol Versatility: Configurable as a Modbus Master or Modbus Slave device.
  • Robust Isolation: Application serial port includes 500V optical isolation from the backplane to prevent electrical noise propagation.
  • Physical Interface Selectivity: Jumper-selectable configurations on the application port support RS-232, RS-422, and RS-485 communication standards.
  • Diagnostic Diagnostics: LEDs display module status, backplane transfer, application status, and active serial port communication activity.

Applications

  • SCADA and telemetry interface integration in oil and gas pipelines.
  • Power distribution monitoring and electrical substation automation.
  • Water and wastewater remote terminal unit (RTU) coordination.
  • Inter-system PLC and DCS networking in chemical processing facilities.

Technical Specifications

Manufacturer ProSoft Technology
Part Number / Model MVI94-MCM
Series MVI94
Product Type Modbus Master/Slave Communication Module
Form Factor Single Slot 1794 Backplane compatible (any slot)
Backplane Current Load 20 mA @ 5 VDC
External Power Supply 12 to 24 VDC (340 to 170 mA)
Operating Temperature 0 to 55 degC (32 to 131 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5% to 95% (without condensation)
Module Dimensions (H x W x D) 9.4 cm x 9.4 cm x 6.9 cm
Shipping Weight 2.0 kg

Connections and Interfaces

Port Designation Physical Connector Type Supported Protocols / Hardware Standards Isolation
PRT1 (Configuration Port) Mini-DIN RS-232 with Hardware Handshaking None
PRT2 (Application Port) Mini-DIN RS-232, RS-422, or RS-485 (Jumper Selectable) 500V optical isolation from backplane

Installation Guidelines

  • Terminal Base Mounting: Mount the module securely onto a compatible 1794 terminal base unit before applying power to the backplane.
  • Jumper Settings: Ensure the hardware jumper settings on the module side panel are configured correctly for the desired physical interface (RS-232, RS-422, or RS-485) prior to mounting and commissioning.
  • External Power Supply Wiring: Connect a clean 12 to 24 VDC external power source to the designated terminal base connections to power the transceiver circuits.
  • Grounding: For optimal optical isolation performance and noise reduction, ensure the terminal base and cabinet housing are properly connected to a low-impedance earth ground.
Loading product navigation…

What control platform is the ProSoft MVI94-MCM designed for?

The ProSoft MVI94-MCM is designed specifically for the Rockwell Automation 1794 FLEX I/O platform, mounting into a single backplane slot.

What are the power requirements for the MVI94-MCM module?

The module requires a 20 mA backplane current at 5 VDC, in addition to an external 12 to 24 VDC power supply drawing between 340 mA and 170 mA.

Does the application port on the module support RS-485?

Yes, the application port (PRT2) supports RS-232, RS-422, and RS-485 physical communication interfaces via jumper selection.

What is the level of isolation provided on the application port?

The application serial port (PRT2) features 500V optical isolation from the backplane to prevent noise and ground loops.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...