ProSoft PLX31-EIP-MBS PLX31 Series EtherNet/IP to Modbus Serial Gateway

ProSoft PLX31-EIP-MBS PLX31 Series EtherNet/IP to Modbus Serial Gateway

Hanya 10 item tersisa di stok
  • Produsen: ProSoft

  • Nomor Produk: PLX31-EIP-MBS

  • Negara asal:Amerika Serikat

  • Jenis Produk: Gateways

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 13.67 cm x 5.05 cm x 11.13 cm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Facilitating seamless data communication between EtherNet/IP-enabled control networks and Modbus serial networks, the ProSoft PLX31-EIP-MBS protocol converter operates as a standalone gateway. Designed to link Rockwell Automation PLCs, including ControlLogix and CompactLogix systems, to Modbus RTU/ASCII-compliant devices, this module acts as a bridge for legacy and modern system integration. It allows the integration of sensors, drives, and specialized instrumentation into high-level control architectures without requiring expensive network overhauls.

The gateway is engineered for harsh industrial environments, offering high electrical isolation on both the Ethernet and serial pathways to prevent damage from ground loops. Featuring a compact form factor for DIN rail installation, the gateway delivers reliable data routing with configurable read/write commands, mapping internal registry memory across protocols with minimum transmission latency.

Features

  • Dual-protocol mapping facilitates real-time data exchange between EtherNet/IP master/slave devices and Modbus RTU/ASCII networks.
  • Complete galvanic isolation on serial and Ethernet communication paths shields control equipment from electrical noise and voltage transients.
  • Integrated diagnostic LEDs provide real-time status indication for power, network connectivity, internal errors, and port traffic.
  • Flexible power input tolerances make the module suitable for diverse industrial power distribution standards.
  • Configuration is managed via user-friendly software utilities, allowing memory offset mapping and quick deployment.

Applications

  • Oil and gas production monitoring, connecting Modbus-based flow meters to EtherNet/IP RTU networks.
  • Water and wastewater plant automation for motor control center (MCC) integration.
  • Power generation and substation systems linking protective relays to central SCADA systems.
  • Factory automation environments standardizing fieldbus devices onto unified Ethernet backbones.

Technical Specifications

Manufacturer ProSoft Technology
Part Number / Model PLX31-EIP-MBS
Power Supply Input 24 VDC nominal (10 VDC to 36 VDC allowable)
Current Load 24 VDC nominal @ 300 mA (10 VDC to 36 VDC @ 610 mA maximum)
Operating Temperature -25 degC to 70 degC (-13 degF to 158 degF)
Storage Temperature -40 degC to 80 degC (-40 degF to 176 degF)
Relative Humidity 5% to 95% RH (non-condensing)
Vibration Protection IEC 60068-2-6; 5G @ 10 to 150 Hz
Ethernet Port 1x 10/100 Mbps RJ45 port (half/full duplex)
Ethernet Isolation 1500 Vrms for 60 seconds (per IEC 60950: 1991 section 5.3.2)
Serial Communication Port 1x RS-232/422/485 configurable port
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 (using RF-based isolation media)
LED Status Indicators Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), Module Status (MS), Serial RX/TX, Ethernet Link/Activity
Dimensions (H x W x D) 13.67 cm x 5.05 cm x 11.13 cm (approximate)
Shipping Weight 2.0 kg

Connections and Interfaces

Interface / Pin Function Description
RJ45 Port EtherNet/IP network communication and configuration port
Serial Port RS-232, RS-422, or RS-485 connection to Modbus slave or master field devices
V+ Terminal Positive DC Power input (10 to 36 VDC)
V- Terminal Negative DC Power return line
GND Terminal Chassis/Functional Ground reference

Installation Guidelines

  • Ensure the unit is mounted on a standard 35mm DIN rail within a dust-free and temperature-regulated control enclosure.
  • Always use shielded Ethernet (Category 5e or higher) and shielded twisted-pair serial cables to limit electromagnetic interference (EMI).
  • Connect the GND terminal directly to a clean, low-resistance functional earth ground bus bar.
  • Ensure there is adequate ventilation spacing of at least 25mm above and below the module during operation.
Loading product navigation…

What power input does the ProSoft PLX31-EIP-MBS require?

The gateway operates on a nominal 24 VDC power supply, but is compatible with a wider input range of 10 to 36 VDC.

Does the serial port on the PLX31-EIP-MBS feature isolation?

Yes, the serial port provides 2500 Vrms signal isolation utilizing RF modulation technology compliant with UL 1577 standards.

Can this gateway be used in extreme temperature environments?

Yes, the module is rated for an industrial operating temperature range of -25 degC to 70 degC (-13 degF to 158 degF).

Which Modbus protocols are supported by the serial port?

The gateway supports both Modbus RTU and Modbus ASCII protocols on its configurable RS-232/422/485 serial port.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...