1 dari 1

Weidmuller 8965480000 ACT20X-2HTI-2SAO-S ACT20X Series Temperature Transducer

Weidmuller 8965480000 ACT20X-2HTI-2SAO-S ACT20X Series Temperature Transducer

Hanya 10 item tersisa di stok
  • Produsen: Weidmuller

  • Nomor Produk: 8965480000

  • Negara asal:Jerman

  • Jenis Produk: Temperature Transducers

  • Pembayaran: T/T, Western Union

  • Berat: 1200g

  • Dimensi: 119.2 mm x 22.5 mm x 113.6 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Processing temperature sensor signals from hazardous areas is the primary function of the Weidmuller 8965480000 ACT20X-2HTI-2SAO-S, a highly reliable 2-channel intrinsically safe temperature transducer. This module isolates, converts, and transmits temperature signals from RTD and thermocouple sensors located in Ex Zone 0, 1, or 2 to the safe area. It features dual-channel density in a compact 22.5 mm housing, providing active or passive 4-20 mA current outputs compatible with standard PLC and DCS analog input cards.

Key Features

  • Dual-Channel Isolation: Two independent, galvanically isolated channels maximize channel density on the DIN rail.
  • Intrinsically Safe Inputs: Certified for direct connection to temperature sensors in Zone 0, 1, and 2 hazardous locations.
  • Universal Sensor Support: Configurable for Pt100, Pt500, Pt1000, Ni100 RTDs, and thermocouple types J, K, T, E, R, S, B, N, L, and U.
  • Comprehensive Diagnostics: Integrated alarm functions detect line interruption, short circuits, supply voltage failure, and internal device errors.
  • FDT/DTM Configuration: Easily parameterized using standard FDT/DTM software via the front-facing service interface.

Industrial Applications

  • Chemical Processing: Monitoring reactor vessel temperatures in explosive atmospheres.
  • Oil & Gas: Temperature measurement on offshore platforms, pipelines, and storage tank farms.
  • Power Generation: Exhaust gas and bearing temperature monitoring in hazardous turbine enclosures.
  • Water & Wastewater: Digester and chemical treatment plant temperature telemetry.

Technical Specifications

Parameter Specification
Manufacturer Weidmuller
Article Number (SKU) 8965480000
Model Code ACT20X-2HTI-2SAO-S
Number of Channels 2
Supply Voltage 19.2 to 31.2 V DC
Power Consumption ≤ 1.4 W
Input Types RTD (Pt100, Pt500, Pt1000, Ni100), Thermocouples (J, K, T, E, R, S, B, N, L, U)
Output Signal 4 to 20 mA (Active or Passive)
Step Response Time ≤ 400 ms (current input), ≤ 1 s (temperature input)
Nominal Switching Voltage ≤ 125 V AC / 110 V DC
Continuous Current ≤ 0.5 A AC / 0.3 A DC
Connection Type Screw connection
Clamping Range 0.5 mm² to 2.5 mm²
Flammability Rating V-0
Protection Degree IP20
Operating Temperature -20 to +60 degC
Humidity 0 to 95% (non-condensing)
Dimensions (H x W x D) 119.2 mm x 22.5 mm x 113.6 mm
Weight 0.180 kg
Shipping Weight (Calculated) 1.200 kg

Connections and Interfaces

Terminal Block Terminal Pin Function / Circuit Assignment
Hazardous Area (Input) 11, 12, 13, 14 Channel 1: RTD (2, 3, or 4-wire) / Thermocouple Input
21, 22, 23, 24 Channel 2: RTD (2, 3, or 4-wire) / Thermocouple Input
Safe Area (Output & Power) 41, 42 Channel 1: 4 to 20 mA Analog Output (Active/Passive)
51, 52 Channel 2: 4 to 20 mA Analog Output (Active/Passive)
31 (+), 32 (-) Device Power Supply (19.2 to 31.2 V DC)

Empirical Engineering Insights

Alternative Models & Compatibility

The ACT20X-2HTI-2SAO-S is the dual-channel variant within Weidmuller's ACT20X intrinsically safe signal converter family. If only a single channel is required, the ACT20X-HTI-SAO-S (single-channel version) can be utilized to reduce hardware costs. Configuration profiles created in the FDT/DTM "WI-Manager" software are fully interchangeable between single and dual-channel models, simplifying commissioning when scaling up system architectures.

Application Pitfalls & Engineering Notes

When mounting multiple ACT20X modules side-by-side on a DIN rail, thermal management is critical. Although the device is rated up to +60 degC, dense installations with continuous 24V DC supply can lead to localized heat build-up. It is recommended to maintain a 5 mm ventilation gap between adjacent modules if the ambient cabinet temperature regularly exceeds 50 degC. Additionally, ensure the loop resistance of the passive output configuration does not exceed the maximum load limits specified for your DCS analog input card.

Commissioning & Wiring Tips

For thermocouple inputs, always ensure that the cold junction compensation (CJC) is correctly configured in the DTM software. If using internal CJC, ensure the terminal block connections are tight and shielded from direct drafts or external heat sources, which can induce measurement drift. For RTD inputs, utilizing a 3-wire or 4-wire connection configuration is highly recommended to automatically compensate for lead wire resistance over long field runs.

Installation Guidelines

CRITICAL WARNING

De-energize all power sources before mounting, wiring, or configuring the device. Ensure strict separation between intrinsically safe (Ex i) field wiring and non-intrinsically safe safe-area wiring in compliance with EN/IEC 60079-14. Failure to maintain physical separation can compromise the explosion protection barrier.

1

Mount the ACT20X module vertically onto a standard TS 35 DIN rail, ensuring the locking foot securely clicks into place.

2

Connect the hazardous area temperature sensor wiring to the blue Ex-input terminals (11-14 and 21-24) using shielded, twisted-pair cables.

3

Wire the safe-area analog outputs (41-42 and 51-52) and the 24 V DC power supply (31-32) to the black terminals.

4

Connect the configuration interface to a PC running Weidmuller WI-Manager (FDT/DTM) to set the sensor type, range, and alarm thresholds.

Loading product navigation…

Can the ACT20X-2HTI-2SAO-S be configured without a PC?

No, this model requires a PC running FDT/DTM software (such as Weidmuller WI-Manager) and a compatible USB interface cable connected to the front service port for parameterization.

What happens to the output signal if a sensor wire breaks?

The module features configurable sensor error detection. In the event of a line interruption or short circuit, the 4-20 mA output can be programmed to go upscale (>= 21.5 mA) or downscale (<= 3.5 mA) to signal a fault to the DCS.

Does this device support both active and passive analog outputs?

Yes, the ACT20X-2HTI-2SAO-S supports both active (where the module powers the loop) and passive (where the receiving DCS/PLC card provides loop power) 4-20 mA configurations.

Is galvanic isolation provided between the two channels?

Yes, complete galvanic isolation is maintained between the input channels, the output channels, and the power supply, preventing ground loops and signal interference.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...

Pemrograman Siklus Gerakan Sumbu Tunggal pada CMZ Servo Drive

Tutorial ini membahas bagaimana fungsi PLC onboard di dalam drive servo CMZ SBD dapat menjalankan program gerakan mandiri, termasuk logika homing, kontrol posisi, dan pergerakan sumbu siklik tanpa...