Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

Hanya 10 item tersisa di stok
  • Produsen: Yokogawa

  • Nomor Produk: AAT141-S00

  • Negara asal:Jepang

  • Jenis Produk: TC/mV Input Modules

  • Pembayaran: T/T, Western Union

  • Berat: 200g

  • Dimensi: 32.8 x 130 x 125.5 mm (W x H x D)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

The Yokogawa AAT141-S00 is a 16-channel isolated thermocouple and millivolt input module designed for FIO systems within CENTUM VP field control stations. It functions as a signal converter by inputting field temperature and voltage signals into internal data for the Field Control Station (FCS). The AAT141-S00 module receives signals from thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage spans ranging from -100 to 150 mV and -20 to 80 mV. It supports dual-redundant configuration and connects externally via a pressure clamp terminal block.

Features

  • 16 isolated input channels for thermocouple and mV signals.
  • Software-selectable TC/mV input types individually configured for CH1 to CH16.
  • Dual-redundant configuration capability.
  • Dedicated pressure clamp terminal external connection interface.
  • Software-configurable burnout detection (UP/DOWN/Not available) for all channels.

Applications

  • Process temperature monitoring using thermocouples.
  • Millivolt analog input signal interfacing in CENTUM VP FIO DCS environments.
  • High-reliability industrial control systems requiring isolated I/O modules.

Ordering Information

Model Suffix Codes Option Codes Description
AAT141     TC/mV Input Module (16-channel, Isolated)
Suffix -S   Standard type
  0   With no explosion protection
  0   Basic type

Technical Specifications

Category Item Specification
Basic Specifications Manufacturer Yokogawa
  Model AAT141-S00
  Number of Input Channels 16, isolated
Input Specifications Input Signal

TC: JIS C1602:1995, IEC584:1995 Type J, K, E, B, R, S, T, N


 

mV: -100 to 150 mV, -20 to 80 mV

  Switching Input Signals TC/mV can be set individually for CH1 to CH16
  Allowable Input Voltage +/-5 V
  Input Resistance (Power ON/OFF) 2 MOhm or larger
Performance Accuracy

+/-30 uV (TC)


 

+/-80 uV for span (-100 to 150 mV)


 

+/-30 uV for span (-20 to 80 mV)

  Reference Junction Compensation Accuracy Within +/-1 degC (varies depending on installation and ambient temperature)
  Allowable Total Resistance 1000 Ohm or less (signal source plus wiring)
  Effect of Signal Source Resistance +/-20 uV per 1000 Ohm (+/-40 uV in dual-redundant configuration)
  Temperature Drift

+/-80 uV/10 degC (-100 to 150 mV input)


 

+/-30 uV/10 degC (TC/-20 to 80 mV input)

  Data Update Period 1 s
  Burn-out Detection All channels can be set together (Not available/available UP/DOWN), Detection time: 60 s
Electrical & Insulation Withstanding Voltage Between input and system: 1500 V AC, for 1 minute
  Maximum Current Consumption 450 mA (5 V DC)
Physical Specifications Weight 0.2 kg
  External Connection Pressure clamp terminal

Installation Guidelines

  • Use a non-ground type thermocouple (TC) because the device is an isolated type module; using ground type TC on multiple channels causes temperature errors due to multi-point ground.
  • Ensure proper installation onto supported ESB, Optical ESB, or ER bus node units.
  • Maintain matching wiring resistance for signal cables to ensure measurement accuracy.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

What input signal types are supported by the module?

The module supports thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage inputs ranging from -100 to 150 mV and -20 to 80 mV.

Why must non-ground type thermocouples be used with this module?

Because the module is an isolated type, using a ground type thermocouple across multiple channels causes temperature measurement errors due to multi-point grounding.

What is the maximum current consumption for the device?

The maximum current consumption is 450 mA at 5 V DC.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jepang

Produk yang Baru Dilihat

Pengetahuan teknis

Memodernisasi HMI Bailey INFI 90 Symphony yang Berjalan di OpenVMS Alpha

Panduan praktis untuk mengganti stasiun operator Bailey Symphony yang sudah usang dan berjalan di OpenVMS Alpha. Panduan ini membandingkan emulasi Alpha, migrasi OpenVMS ke x86, pemindahan platform...

Mengapa Data Pemeliharaan Sangat Penting bagi Keandalan Industri

Data pemeliharaan menghubungkan perintah kerja, sinyal sensor, riwayat aset, biaya, dan pengetahuan teknisi. Jika digunakan dengan baik, data ini meningkatkan perencanaan, keandalan, pemeliharaan...

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kendali gerak industri dengan menggantikan sistem pneumatik dan hidraulik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan cara sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan eksponensiasi dalam otomasi industri. Artikel ini...

Logika Boolean Tingkat Lanjut dengan Pemrograman PLC FBD: Penerapan Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean tingkat lanjut yang digunakan dalam pemrograman PLC, di luar operasi dasar AND, OR, dan NOT. Artikel ini membahas cara menggunakan alat seperti...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Mulai dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan cara pengendali merespons perubahan...