The 060G2110 (060G2110) is a high-reliability pressure transmitter from the Danfoss AKS 33 series, specifically optimized for refrigeration and air conditioning control systems. This industrial-grade sensor converts process pressure into a standardized 4-20 mA current signal, facilitating accurate and stable data transmission over long distances without signal degradation. Engineered to perform in extreme thermal conditions, the 060G2110 operates effectively within a medium temperature range of -40 to 85 deg C. Its sealed gauge reference design ensures that pressure readings remain independent of barometric fluctuations, making it a critical component for maintaining precision in high-capacity chillers, commercial food storage, and industrial cooling racks.

Technical Configuration

The 060G2110 is built for seamless integration into high-performance automation loops:

  • Industrial Current Signal: The 4-20 mA output provides high immunity to electrical noise, ensuring consistent performance in mechanical rooms with high electromagnetic interference.

  • Sealed Gauge Reference: Utilizing a factory-set internal reference pressure, the sensor delivers accurate relative pressure data regardless of local altitude or atmospheric changes.

  • Rugged Electrical Interface: Equipped with an EN 175301-803-A (DIN) angular connector, the unit offers a secure, vibration-resistant connection with an IP65 enclosure rating.

  • Thermal Compensation: Includes active electronic compensation for temperatures between 0 and 80 deg C, minimizing thermal drift and ensuring signal linearity across varying seasonal conditions.

Technical Specifications

Feature Specification
Model 060G2110 (Type AKS 33)
Brand Danfoss
Output Signal 4 - 20 mA Current
Pressure Reference Sealed Gauge
Overload Pressure 40 bar (580 psi)
Electrical Connection Angular Connector (EN 175301-803-A)
Enclosure Rating IP65
Medium Temp. Range -40 to 85 deg C
Operating Voltage 10 to 30 VDC
Net Weight 0.168 kg
Shipping Weight 1.0 kg

Technical FAQs

How does the current signal benefit large-scale HVAC installations?

The current signal of the 060G2110 allows for cable runs of hundreds of meters without voltage drop issues. This is essential in large commercial buildings where the sensor is located on a rooftop condenser while the main PLC cabinet is several floors below.

Can the 060G2110 be used with Ammonia (R717) or CO2 (R744)?

The AKS 33 series is designed for compatibility with most common refrigerants, including HFC, HCFC, and Ammonia. For CO2 applications, ensure the 40 bar overload rating and the specific operating range match your system's transcritical or subcritical pressures.

What is the response time of the AKS 33 sensor?

While optimized for stability, the AKS 33 features a fast internal response time (typically < 4 ms), allowing the controller to react quickly to rapid pressure changes in the suction or discharge lines, which helps in preventing compressor liquid slugging.


Engineering & Installation Guide

  • Pulse Protection: In systems with reciprocating compressors or fast-acting solenoid valves, pressure pulsations can cause mechanical fatigue to the diaphragm. It is recommended to install the transmitter using a capillary tube or a pressure snubber to dampen high-frequency pressure spikes.

  • Sealing and Maintenance: When attaching the angular connector, verify that the rubber profile gasket is in place. Tighten the central screw to a torque of 0.4 Nm to ensure the IP65 seal is effective against humidity and condensation, which are common in refrigeration environments.

  • Grounding and Shielding: To maintain the 0.5% accuracy, utilize a twisted-pair shielded cable. Connect the shield only at the PLC/Controller end to avoid creating ground loops, which can introduce offset errors into the 4-20 mA loop.

 

Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

060G2110

Stock &amp; lead time on request

Call
1 su 1

060G2110 Danfoss AKS 33 Heavy Duty Pressure Transmitter

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 060G2110

  • Country of origin:United States

  • Product Type: Pressure Transmitter | AKS 33

  • Payment: T/T, Western Union

  • Weight: 168g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The 060G2110 (060G2110) is a high-reliability pressure transmitter from the Danfoss AKS 33 series, specifically optimized for refrigeration and air conditioning control systems. This industrial-grade sensor converts process pressure into a standardized 4-20 mA current signal, facilitating accurate and stable data transmission over long distances without signal degradation. Engineered to perform in extreme thermal conditions, the 060G2110 operates effectively within a medium temperature range of -40 to 85 deg C. Its sealed gauge reference design ensures that pressure readings remain independent of barometric fluctuations, making it a critical component for maintaining precision in high-capacity chillers, commercial food storage, and industrial cooling racks.

Technical Configuration

The 060G2110 is built for seamless integration into high-performance automation loops:

  • Industrial Current Signal: The 4-20 mA output provides high immunity to electrical noise, ensuring consistent performance in mechanical rooms with high electromagnetic interference.

  • Sealed Gauge Reference: Utilizing a factory-set internal reference pressure, the sensor delivers accurate relative pressure data regardless of local altitude or atmospheric changes.

  • Rugged Electrical Interface: Equipped with an EN 175301-803-A (DIN) angular connector, the unit offers a secure, vibration-resistant connection with an IP65 enclosure rating.

  • Thermal Compensation: Includes active electronic compensation for temperatures between 0 and 80 deg C, minimizing thermal drift and ensuring signal linearity across varying seasonal conditions.

Technical Specifications

Feature Specification
Model 060G2110 (Type AKS 33)
Brand Danfoss
Output Signal 4 - 20 mA Current
Pressure Reference Sealed Gauge
Overload Pressure 40 bar (580 psi)
Electrical Connection Angular Connector (EN 175301-803-A)
Enclosure Rating IP65
Medium Temp. Range -40 to 85 deg C
Operating Voltage 10 to 30 VDC
Net Weight 0.168 kg
Shipping Weight 1.0 kg

Technical FAQs

How does the current signal benefit large-scale HVAC installations?

The current signal of the 060G2110 allows for cable runs of hundreds of meters without voltage drop issues. This is essential in large commercial buildings where the sensor is located on a rooftop condenser while the main PLC cabinet is several floors below.

Can the 060G2110 be used with Ammonia (R717) or CO2 (R744)?

The AKS 33 series is designed for compatibility with most common refrigerants, including HFC, HCFC, and Ammonia. For CO2 applications, ensure the 40 bar overload rating and the specific operating range match your system's transcritical or subcritical pressures.

What is the response time of the AKS 33 sensor?

While optimized for stability, the AKS 33 features a fast internal response time (typically < 4 ms), allowing the controller to react quickly to rapid pressure changes in the suction or discharge lines, which helps in preventing compressor liquid slugging.


Engineering & Installation Guide

  • Pulse Protection: In systems with reciprocating compressors or fast-acting solenoid valves, pressure pulsations can cause mechanical fatigue to the diaphragm. It is recommended to install the transmitter using a capillary tube or a pressure snubber to dampen high-frequency pressure spikes.

  • Sealing and Maintenance: When attaching the angular connector, verify that the rubber profile gasket is in place. Tighten the central screw to a torque of 0.4 Nm to ensure the IP65 seal is effective against humidity and condensation, which are common in refrigeration environments.

  • Grounding and Shielding: To maintain the 0.5% accuracy, utilize a twisted-pair shielded cable. Connect the shield only at the PLC/Controller end to avoid creating ground loops, which can introduce offset errors into the 4-20 mA loop.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...