Danfoss

084G2101 Danfoss EMP 2 Industrial Pressure Transmitter 5 bar

SKU 084G2101

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss
  • Product No.: 084G2101
  • Origin United States
  • Product Type: Controles Industriales Pressure Transmitter
  • Payment: T/T, Western Union
  • Weight: 2.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The 084G2101 (084G2101) is a rugged EMP 2 series pressure transmitter from Danfoss, engineered for demanding industrial and marine applications. Designed to measure a pressure range of -1 to 5 bar (-14.5 to 72.52 psi), this transmitter provides highly accurate feedback for both vacuum and low-pressure systems. It converts mechanical pressure into a standardized 4-20 mA current signal, ensuring reliable data transmission even over long distances. Built to withstand harsh environments, the 084G2101 features a sealed gauge pressure reference, an IP65-rated enclosure, and a high overload pressure limit of 35 bar, making it a critical component for monitoring hydraulic, pneumatic, and steam systems where signal stability and durability are paramount.

Technical Configuration

The 084G2101 utilizes a heavy-duty sensor platform optimized for signal integrity:

  • Sealed Gauge Reference: Provides a consistent baseline regardless of local atmospheric pressure changes or altitude, ensuring precision in diverse geographical locations.

  • Precision Current Loop: The 4-20 mA output is resistant to electrical noise and voltage drops, featuring low (3.6 mA) and high (22.4 mA) clipping levels for advanced error detection.

  • Robust Overload Protection: With a 35 bar maximum overload rating, the internal sensor is protected against pressure spikes up to seven times its maximum rated range.

  • Industrial Connection: Equipped with a versatile G 1/4 external and 1/2 inch internal thread per EN 228-1, supported by a Pg 13.5 electrical terminal block for secure field wiring.

Technical Specifications

Feature Specification
Model 084G2101 (EMP 2)
Brand Danfoss
Pressure Range -1 to 5 bar (-14.5 to 72.52 psi)
Output Signal 4 - 20 mA Current
Accuracy (Typical) 0.5% FS
Overload Pressure 35 bar
Response Time 4 ms max.
Supply Voltage 12 - 32 VDC
Electrical Connection Terminal Block (Pg 13.5 Gland)
Enclosure Rating IP65
Medium Temp. Range -10 to 70 deg C
Shipping Weight 2.0 kg

Technical FAQs

How do the clipping levels (3.6 mA and 22.4 mA) assist in troubleshooting?

These levels allow the controller to distinguish between a valid reading and a system fault. If the signal drops to 3.6 mA, it typically indicates a sensor error or extreme under-pressure. If it rises to 22.4 mA, it suggests a short circuit or over-pressure condition. A signal of 0 mA would immediately indicate a broken wire.

Is this transmitter suitable for marine engine rooms?

Yes. The EMP 2 series is specifically designed for marine and heavy industrial use. The IP65 enclosure and the vibration-resistant terminal block make the 084G2101 ideal for monitoring oil, water, or air pressures in the proximity of large engines and pumps.

Can the 084G2101 be used for vacuum applications?

Absolutely. With a minimum pressure range of -1 bar, this transmitter is fully capable of monitoring vacuum levels, making it useful for suction side monitoring in pumping stations or vacuum-assisted process control.


Engineering & Installation Guide

  • Wiring Protocol: The unit uses a 2-wire connection (P = Positive supply, N = Common). To maintain the 0.5% typical accuracy, use shielded twisted-pair cabling. The shield should be grounded only at the PLC or receiver end to prevent ground loops that could introduce signal offsets.

  • Terminal Maintenance: When performing field wiring via the Pg 13.5 gland, ensure the cable diameter matches the gland seal. Tighten the terminal block cover securely to maintain the IP65 rating; moisture ingress is the leading cause of signal drift in industrial transmitters.

  • Mounting for Longevity: For applications with high vibration, mount the transmitter on a rigid support. If the media temperature exceeds 70 deg C, use a siphon or capillary tube to dissipate heat before it reaches the sensor diaphragm to stay within the compensated temperature range of 0 to 70 deg C.

 

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

084G2101

Stock & lead time on request

Call
1 su 1

084G2101 Danfoss EMP 2 Industrial Pressure Transmitter 5 bar

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 084G2101

  • Country of origin:United States

  • Product Type: Controles Industriales Pressure Transmitter

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The 084G2101 (084G2101) is a rugged EMP 2 series pressure transmitter from Danfoss, engineered for demanding industrial and marine applications. Designed to measure a pressure range of -1 to 5 bar (-14.5 to 72.52 psi), this transmitter provides highly accurate feedback for both vacuum and low-pressure systems. It converts mechanical pressure into a standardized 4-20 mA current signal, ensuring reliable data transmission even over long distances. Built to withstand harsh environments, the 084G2101 features a sealed gauge pressure reference, an IP65-rated enclosure, and a high overload pressure limit of 35 bar, making it a critical component for monitoring hydraulic, pneumatic, and steam systems where signal stability and durability are paramount.

Technical Configuration

The 084G2101 utilizes a heavy-duty sensor platform optimized for signal integrity:

  • Sealed Gauge Reference: Provides a consistent baseline regardless of local atmospheric pressure changes or altitude, ensuring precision in diverse geographical locations.

  • Precision Current Loop: The 4-20 mA output is resistant to electrical noise and voltage drops, featuring low (3.6 mA) and high (22.4 mA) clipping levels for advanced error detection.

  • Robust Overload Protection: With a 35 bar maximum overload rating, the internal sensor is protected against pressure spikes up to seven times its maximum rated range.

  • Industrial Connection: Equipped with a versatile G 1/4 external and 1/2 inch internal thread per EN 228-1, supported by a Pg 13.5 electrical terminal block for secure field wiring.

Technical Specifications

Feature Specification
Model 084G2101 (EMP 2)
Brand Danfoss
Pressure Range -1 to 5 bar (-14.5 to 72.52 psi)
Output Signal 4 - 20 mA Current
Accuracy (Typical) 0.5% FS
Overload Pressure 35 bar
Response Time 4 ms max.
Supply Voltage 12 - 32 VDC
Electrical Connection Terminal Block (Pg 13.5 Gland)
Enclosure Rating IP65
Medium Temp. Range -10 to 70 deg C
Shipping Weight 2.0 kg

Technical FAQs

How do the clipping levels (3.6 mA and 22.4 mA) assist in troubleshooting?

These levels allow the controller to distinguish between a valid reading and a system fault. If the signal drops to 3.6 mA, it typically indicates a sensor error or extreme under-pressure. If it rises to 22.4 mA, it suggests a short circuit or over-pressure condition. A signal of 0 mA would immediately indicate a broken wire.

Is this transmitter suitable for marine engine rooms?

Yes. The EMP 2 series is specifically designed for marine and heavy industrial use. The IP65 enclosure and the vibration-resistant terminal block make the 084G2101 ideal for monitoring oil, water, or air pressures in the proximity of large engines and pumps.

Can the 084G2101 be used for vacuum applications?

Absolutely. With a minimum pressure range of -1 bar, this transmitter is fully capable of monitoring vacuum levels, making it useful for suction side monitoring in pumping stations or vacuum-assisted process control.


Engineering & Installation Guide

  • Wiring Protocol: The unit uses a 2-wire connection (P = Positive supply, N = Common). To maintain the 0.5% typical accuracy, use shielded twisted-pair cabling. The shield should be grounded only at the PLC or receiver end to prevent ground loops that could introduce signal offsets.

  • Terminal Maintenance: When performing field wiring via the Pg 13.5 gland, ensure the cable diameter matches the gland seal. Tighten the terminal block cover securely to maintain the IP65 rating; moisture ingress is the leading cause of signal drift in industrial transmitters.

  • Mounting for Longevity: For applications with high vibration, mount the transmitter on a rigid support. If the media temperature exceeds 70 deg C, use a siphon or capillary tube to dissipate heat before it reaches the sensor diaphragm to stay within the compensated temperature range of 0 to 70 deg C.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...