Product overview

The Honeywell 51401583-100 is the Enhanced Process Network Interface (EPNI) logic board used in TDC 3000 Network Interface Module assemblies. The NIM connects the Universal Control Network with the Local Control Network and its process-manager nodes. This listing is for the logic board, not the complete redundant NIM node.

Technical specifications

Manufacturer Honeywell
Part number 51401583-100
Product type Enhanced Process Network Interface logic board
System family TDC 3000 / TPS
Network role Logic interface for UCN-to-LCN communication in a NIM assembly
Associated CE modem paddle 51305896-200 in documented configurations
Associated non-CE modem paddle 51305896-100, subject to installed NIM design
Node arrangement NIMs are commonly installed as a redundant pair; verify the actual architecture

Compatibility and replacement boundary

Confirm the EPNI board revision and firmware, modem paddle-board part number, UCN/LCN cabling, NIM node definition and redundancy. Sequence-of-events timing requirements may impose a minimum firmware revision, so the full board label is required before supply.

Dimensions and shipping

Exact PCB dimensions were not confirmed in accessible manufacturer data. Estimated package: 46 × 46 × 10 cm; estimated shipping weight 2.0 kg with rigid ESD protection. Final values require warehouse measurement.

FAQ

What is Honeywell 51401583-100?

It is the EPNI logic board used in a TDC 3000 Network Interface Module.

Is it the complete NIM?

No. The modem paddle, cabling, chassis components and redundant partner are separate unless explicitly included.

Which modem paddle is associated with it?

Documented configurations use 51305896-200 for the CE NIM; non-CE hardware uses a separate paddle-board version.

Why must firmware be checked?

Certain functions, including sequence-of-events timing in historical configurations, depend on a suitable EPNI firmware revision.

Are package dimensions exact?

No. They are estimated and must be confirmed by the warehouse.

View all FAQs →

Quantità
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 su 1
Only 2 item(s) left in stock
Quantità
Visualizza dettagli completi
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1746-A7 Verifiche di sostituzione del telaio: slot, alimentazione e interconnessioni

Una lista di controllo tecnica per sostituire un Allen-Bradley 1746-A7: verificare la serie del telaio, il carico del backplane, la disposizione degli slot, i cavi di interconnessione, il montaggio,...

Controlli per la sostituzione di IC200MDL650: polarità logica, filtri e comuni

Una guida alla sostituzione sul campo del GE Fanuc IC200MDL650, che tratta la logica negativa in base alla revisione, quattro gruppi comuni, le soglie a 24 VDC, il filtraggio degli ingressi, i...

Controlli per la sostituzione di IC697CPX935: memoria, porte e alimentazione del rack

Una guida alla sostituzione dell’IC697CPX935 incentrata sulle esigenze sul campo, che illustra la memoria veloce, il comportamento seriale dipendente dal firmware, l’alimentazione del rack, il...

Controlli per la sostituzione dell’IC693DSM324: FSSB, firmware e controllo follower

Una guida alla sostituzione dell'IC693DSM324 sul campo, con controlli dell'unità host Series 90-30, registri della catena servo FSSB, budget di alimentazione a 5 V, limiti del firmware, controllo...

Verifiche di sostituzione HIMA F3430: valori nominali dei contatti e limiti di sicurezza

Una guida alla sostituzione di HIMA F3430, pensata per il lavoro sul campo, che tratta la portata dei contatti del relè, il declassamento per carichi CC, i fusibili, le differenze tra F3330 e F3331,...

Verifiche per la sostituzione di IC697PWR710: budget di carico e limiti dei rack doppi

Una guida pratica alla sostituzione dell’IC697PWR710, con calcoli del carico a 5 V, limiti dei rack doppi, cavi di estensione, controlli degli ingressi, comportamento delle protezioni e rischi legati...