ABB 57160001-TZ DSTD 110A S100 I/O Connection Unit
SKU DSTD110A 57160001-TZ
Disponibile
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
ABB
Product No.:
DSTD110A 57160001-TZ
Country of origin:Sweden
Product Type:
Connection Unit
Barcode:
85389091
Payment:
T/T, Western Union
Weight:
365g
Dimensions:
157.5 x 54 x 324 mm
Shipping port:
Xiamen
Warranty:
12 months
Description
The ABB 57160001-TZ DSTD 110A is a termination connection unit designed for interfacing digital output signals within ABB industrial control platforms. Serving as a core connection component for the S100 I/O system, it routes signals between field devices and central processing sub-racks across Advant Controller 450, Advant OCS with Master SW, MasterPiece 200/1, MOD 300, and 800xA control architectures.
Engineered specifically for digital output board applications—such as the DSDO 115 series—the 57160001-TZ DSTD 110A accommodates up to 32 digital output channels with a maximum operating voltage rating of 60 V. The unit acts as a field wiring termination interface, providing organized point-to-point connections for discrete signals while simplifying field cable management inside cabinet enclosures.
The ABB DSTD 110A features a compact physical footprint measuring 157.5 mm wide by 54 mm high by 324 mm deep, allowing convenient mounting on standard cabinet sub-racks or mounting rails. It serves as a field-proven termination interface in both existing legacy systems and updated DCS I/O configurations requiring reliable channel termination.
Features
32-Channel Capacity: Designed to support up to 32 discrete channels for digital output board connection.
60 V Maximum Rating: Standard voltage handling capability rated at a maximum of 60 V for industrial digital output signals.
S100 I/O System Integration: Directly compatible with ABB S100 I/O termination structures and digital output kits such as DSDO 115K12 and DSDO 115K01.
Multi-Platform Support: Integrates across ABB control platforms including Advant Controller 450, MasterPiece 200/1, Advant OCS with MOD 300 SW, System 800xA, and Compact Product Suite.
Compact Physical Design: Standard panel dimensions of 157.5 mm x 54 mm x 324 mm ensure space-efficient cabinet integration.
Applications
Digital Output Signal Termination: Interfacing 32-channel digital output modules (e.g., DSDO 115 series) with field-side actuators, solenoids, and switching relays.
Advant Master & 800xA System Expansion: Serving as the field connection point for S100 I/O racks in Advant Controller 450 and System 800xA DCS installations.
Cabinet Retrofits and Maintenance: Direct replacement termination unit for legacy MasterPiece 200/1 or MOD 300 I/O subsystems.
Ordering Information
Product ID
ABB Type Designation
Description
57160001-TZ
DSTD 110A
Connection Unit for Digital Output Board (32 Channels, max 60 V)
EXC57160001-TZ
DSTD 110A
Exchange Service Part Number for DSTD 110A Connection Unit
Multi-pin connection to S100 I/O digital output boards (e.g., DSDO 115) via system cable
Field Wiring Terminals
Multi-channel termination blocks for up to 32 digital output field signals
Installation Guidelines
Safety Isolation: Disconnect system power to the targeted I/O rack and field circuits prior to starting work.
Pre-Installation Inspection: Verify that the connection unit part number matches 57160001-TZ (DSTD 110A) and inspect terminal blocks for physical integrity.
Mounting: Secure the unit in the designated I/O cabinet space using the compatible mounting screws kit (3BSE021202R1).
System Cable Attachment: Connect the system ribbon/interface cable from the S100 I/O digital output board to the unit's board interface.
Field Wiring: Land field digital output conductors onto the designated channel terminals, ensuring proper tightening torque and line polarization.
Grounding & Shielding: Ensure all cable shields and grounding connections meet ABB S100 I/O cabinet installation standards.
Commissioning Check: Confirm channel signal continuity and check for correct potential before re-energizing field circuits.
Compliance and Certifications
Specification / Directive
Details
RoHS Compliance
Exempted from the scope of EU Directive 2011/65/EU as provided in Article 2(4)(c), (e), (f), and (j)
WEEE Category
Category 5 (Small Equipment - No External Dimension More Than 50 cm)
Customs / HS Code
853890 (85389091)
FAQ
What is the primary function of the ABB 57160001-TZ DSTD 110A?
The ABB 57160001-TZ DSTD 110A serves as a 32-channel digital connection unit designed to interface S100 I/O digital output boards with external field wiring, supporting voltage ratings up to 60 V.
Which control platforms support the ABB DSTD 110A termination unit?
The ABB DSTD 110A is compatible with systems utilizing S100 I/O modules, including Advant Controller 450, Advant OCS with Master SW, MasterPiece 200, and integrated 800xA or MOD 300 control systems.
Which output kit assemblies include the ABB 57160001-TZ connection unit?
The ABB 57160001-TZ connection unit is used as a core component within the DSDO 115K12 (3BSE019933R1) and DSDO 115K01 (5730030-VC) digital output kits.
What are the physical dimensions and weight of the ABB DSTD 110A unit?
The ABB DSTD 110A connection unit measures 157.5 mm in width, 54 mm in height, and 324 mm in depth, with an official net weight of 0.365 kg.
A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.
Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.
Un joystick industriale è solo il primo elemento di una catena di comando del movimento sicura. Questa guida tratta le scelte relative al rilevamento, al cablaggio, alla convalida dei segnali, alla...
La regolazione PID diventa più sicura quando gli ingegneri possono vedere come le azioni proporzionale, integrale e derivativa modificano errore, uscita e risposta nel tempo. Questa guida trasforma i...
Un asse lineare deve essere collaudato meccanicamente prima di iniziare una taratura aggressiva. Questo flusso di messa in servizio comprende la scalatura, la direzione, i limiti, il ritorno a zero,...
Scegliendo una selezione si ottiene un aggiornamento completo della pagina.