Description

The ABB HS810 is a high-performance head station designed for seamless integration within ABB FieldIT and industrial distributed control systems (DCS). Serving as a critical interface gateway, this module bridges PROFIBUS DP and PROFIBUS PA networks, enabling efficient communication and data exchange between high-speed automation controllers and field instrumentation.

Engineered for high reliability in demanding process automation environments, the ABB HS810 features support for up to 8 field channels and redundant PROFIBUS DP connections. This robust architecture ensures continuous operation and fault-tolerant data transmission, significantly reducing the risk of process downtime in critical industrial applications.

The unit features a compact form factor optimized for standard industrial enclosures, simplifying physical installation and panel layout. Built to withstand harsh operational conditions, the ABB HS810 delivers dependable performance across a wide ambient temperature range while providing advanced diagnostic capabilities for real-time network monitoring and proactive maintenance.

Features

  • Bridges PROFIBUS DP and PROFIBUS PA networks for seamless fieldbus integration
  • Supports up to 8 communication channels for extensive field device connectivity
  • Redundant PROFIBUS DP connection ensures high availability and continuous operation
  • Advanced diagnostic capabilities for real-time monitoring and troubleshooting
  • Compact and lightweight design tailored for standard industrial cabinet mounting
  • Designed for integration within ABB FieldIT and DCS automation architectures

Applications

  • Process control systems in chemical and petrochemical plants
  • Oil and gas upstream and downstream automation
  • Water and wastewater treatment facility management
  • Power generation and auxiliary plant systems
  • Discrete and hybrid manufacturing plant networks

Technical Specifications

Parameter Specification
Manufacturer ABB
Product Type Head Station / Fieldbus Gateway
Model / Part Number HS810
Product Range FieldIT
System Compatibility ABB Distributed Control Systems (DCS)
Supported Protocols PROFIBUS DP, PROFIBUS PA
Channel Capacity Up to 8 Channels
Redundancy Redundant PROFIBUS DP connection support
Operating Temperature -20 degC to +55 degC
Storage Temperature -40 degC to +70 degC
Dimensions (H x W x D) 11.8 cm x 13.6 cm x 8.5 cm
Net Weight 0.38 kg
Country of Origin Sweden

Connections / Interfaces

Interface Function
PROFIBUS DP Port Primary and redundant controller-level network connection
PROFIBUS PA Terminals Field-level instrumentation loops (up to 8 channels)
Power Supply Terminals Low-voltage DC input for module power

Installation Guidelines

  1. Verify the part number and inspect the ABB HS810 module for any transit damage prior to installation.
  2. Ensure all associated power supplies and network segments are fully de-energized before handling hardware.
  3. Mount the unit securely onto the designated industrial rail or backplane within the control cabinet, ensuring adequate clearance for ventilation.
  4. Connect the PROFIBUS DP and PROFIBUS PA cables to the appropriate terminal blocks, verifying correct shielding and grounding.
  5. Apply power and configure the module parameters via the engineering station software to establish communication.

Compliance and Certifications

  • Manufactured in accordance with applicable industrial CE standards
  • Designed for standard industrial electromagnetic compatibility (EMC)
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the ABB HS810?
The ABB HS810 functions as a head station and network gateway designed to seamlessly interface PROFIBUS DP backbone networks with PROFIBUS PA field instruments within ABB DCS environments.
How many channels does the ABB HS810 support?
The ABB HS810 supports up to 8 communication channels, allowing connection to multiple field devices on the PROFIBUS PA network segment.
Does the ABB HS810 support network redundancy?
Yes, the ABB HS810 features a redundant PROFIBUS DP connection to ensure continuous data transmission and high availability in critical industrial processes.
What are the physical dimensions and weight of the ABB HS810?
The ABB HS810 measures 11.8 cm x 13.6 cm x 8.5 cm and has a net weight of approximately 0.38 kg.
What is the operating temperature range for the ABB HS810?
The ABB HS810 operates reliably in ambient temperatures ranging from -20 degC to +55 degC.
Reviews

HS810

Stock & lead time on request

Call
1 su 3

ABB HS810 Head Station For Profibus DP/PA

Only 2 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: HS810

  • Country of origin:Switzerland

  • Product Type: Head Stations

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 380g

  • Dimensions: 11.8 cm x 13.6 cm x 8.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The ABB HS810 is a high-performance head station designed for seamless integration within ABB FieldIT and industrial distributed control systems (DCS). Serving as a critical interface gateway, this module bridges PROFIBUS DP and PROFIBUS PA networks, enabling efficient communication and data exchange between high-speed automation controllers and field instrumentation.

Engineered for high reliability in demanding process automation environments, the ABB HS810 features support for up to 8 field channels and redundant PROFIBUS DP connections. This robust architecture ensures continuous operation and fault-tolerant data transmission, significantly reducing the risk of process downtime in critical industrial applications.

The unit features a compact form factor optimized for standard industrial enclosures, simplifying physical installation and panel layout. Built to withstand harsh operational conditions, the ABB HS810 delivers dependable performance across a wide ambient temperature range while providing advanced diagnostic capabilities for real-time network monitoring and proactive maintenance.

Features

  • Bridges PROFIBUS DP and PROFIBUS PA networks for seamless fieldbus integration
  • Supports up to 8 communication channels for extensive field device connectivity
  • Redundant PROFIBUS DP connection ensures high availability and continuous operation
  • Advanced diagnostic capabilities for real-time monitoring and troubleshooting
  • Compact and lightweight design tailored for standard industrial cabinet mounting
  • Designed for integration within ABB FieldIT and DCS automation architectures

Applications

  • Process control systems in chemical and petrochemical plants
  • Oil and gas upstream and downstream automation
  • Water and wastewater treatment facility management
  • Power generation and auxiliary plant systems
  • Discrete and hybrid manufacturing plant networks

Technical Specifications

Parameter Specification
Manufacturer ABB
Product Type Head Station / Fieldbus Gateway
Model / Part Number HS810
Product Range FieldIT
System Compatibility ABB Distributed Control Systems (DCS)
Supported Protocols PROFIBUS DP, PROFIBUS PA
Channel Capacity Up to 8 Channels
Redundancy Redundant PROFIBUS DP connection support
Operating Temperature -20 degC to +55 degC
Storage Temperature -40 degC to +70 degC
Dimensions (H x W x D) 11.8 cm x 13.6 cm x 8.5 cm
Net Weight 0.38 kg
Country of Origin Sweden

Connections / Interfaces

Interface Function
PROFIBUS DP Port Primary and redundant controller-level network connection
PROFIBUS PA Terminals Field-level instrumentation loops (up to 8 channels)
Power Supply Terminals Low-voltage DC input for module power

Installation Guidelines

  1. Verify the part number and inspect the ABB HS810 module for any transit damage prior to installation.
  2. Ensure all associated power supplies and network segments are fully de-energized before handling hardware.
  3. Mount the unit securely onto the designated industrial rail or backplane within the control cabinet, ensuring adequate clearance for ventilation.
  4. Connect the PROFIBUS DP and PROFIBUS PA cables to the appropriate terminal blocks, verifying correct shielding and grounding.
  5. Apply power and configure the module parameters via the engineering station software to establish communication.

Compliance and Certifications

  • Manufactured in accordance with applicable industrial CE standards
  • Designed for standard industrial electromagnetic compatibility (EMC)
Loading product navigation…

What is the primary function of the ABB HS810?

The ABB HS810 functions as a head station and network gateway designed to seamlessly interface PROFIBUS DP backbone networks with PROFIBUS PA field instruments within ABB DCS environments.

How many channels does the ABB HS810 support?

The ABB HS810 supports up to 8 communication channels, allowing connection to multiple field devices on the PROFIBUS PA network segment.

Does the ABB HS810 support network redundancy?

Yes, the ABB HS810 features a redundant PROFIBUS DP connection to ensure continuous data transmission and high availability in critical industrial processes.

What are the physical dimensions and weight of the ABB HS810?

The ABB HS810 measures 11.8 cm x 13.6 cm x 8.5 cm and has a net weight of approximately 0.38 kg.

What is the operating temperature range for the ABB HS810?

The ABB HS810 operates reliably in ambient temperatures ranging from -20 degC to +55 degC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Switzerland

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.