Allen-Bradley

Allen-Bradley 1756-ENBT ControlLogix EtherNet/IP Bridge Module

SKU 1756-ENBT

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley
  • Product No.: 1756-ENBT
  • Origin United States
  • Product Type: Communication Modules
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.29 kg
  • Dimensions: 35 mm x 140 mm x 145 mm (W x H x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1756-ENBT ControlLogix EtherNet/IP Bridge Module

Quantità

Product Description

Description

The Allen-Bradley 1756-ENBT is a chassis-based industrial communication module engineered for the ControlLogix hardware architecture. It functions as a dedicated bridge link between localized automation infrastructure and macro-level plant networks, handling explicit messaging and real-time distributed data transfers over EtherNet/IP links. Incorporating 1 standard copper RJ45 socket that handles 10/100 Mbps communication rates over Category 5 network infrastructure, the 1756-ENBT supports 64 TCP/IP connections alongside up to 128 simultaneous CIP connections to execute multi-node monitoring and distributed standard remote IO interfaces.

Employing a standardized open-style enclosure rated to occupy a single slot width inside any standard hardware rack, this communication module uses producer-consumer networking mechanisms to facilitate seamless data distribution across multiple distributed system controllers. Field personnel can perform diagnostic assessments directly via the onboard front digital indicator panel. The circuit framework provides up to 30V continuous operational isolation between the physical network cabling and the backplane logic components to insulate internal automation architectures against transient external electrical surges.

Features

  • Bridges Control Network Architectures: Provides a specialized communication interface linking upstream factory networking layers with standard remote I/O sub-assemblies.
  • Dual Connection Topologies: Features dual capability with support for a maximum of 64 TCP/IP connections alongside 128 physical CIP connection configurations.
  • Integrated Hardware Diagnostics: Front-mounted localized digital indicators simplify system verification by reporting live hardware states and communication errors.
  • Industrial Media Support: Built with a standard 10/100 Mbps copper RJ45 port compatible with shielded or unshielded category 5 twisted-pair media lines.

Applications

  • Remote I/O station integration and localized distributed control rack telemetry.
  • Standardized supervisory control and real-time plant data management links.
  • Inter-chassis processor logic sharing and machine-to-machine data synchronization.
  • Variable frequency drive monitoring and integrated remote peripheral instrumentation data paths.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Catalog Number 1756-ENBT
Sub Brand ControlLogix
Type Communication Module
Interface 1 Copper RJ45 (10/100 Mbps)
Number of Channels 1
Communication Rate 10/100 Mbps
Connections Supported (Max) TCP: 64, CIP: 128
CIP Unconnected Messages 64 + 64 (backplane + Ethernet)
Current Draw 700mA @ 5.1V DC, 3mA @ 24V DC
Power Dissipation 3.7 W
Thermal Dissipation 12.6 btu/h
Isolation Voltage 30V (continuous), basic insulation type, Ethernet network to backplane
Enclosure Type Rating None (open-style)
Slot Width 1
ATEX Temp Code T4
Operating Temperature 0 Celsius to 60 Celsius (32 Fahrenheit to 140 Fahrenheit)
Storage Temperature -40 Celsius to 85 Celsius (-40 Fahrenheit to 185 Fahrenheit)
Relative Humidity 5...95% noncondensing
Vibration 2 G @ 10...500 Hz
Operating Shock 30 G
Non-Operating Shock 50 G

Connections/Interfaces

Connector Pin Function
Ethernet RJ45 Port Category 5 shielded or unshielded twisted pair network connection interface

Installation Guidelines

  • Module Insertion: Align the circuit board edge with the top and bottom channel guides of a free rack slot inside the target chassis. Push firmly inward until the securing mechanism locks completely.
  • Network Media Routing: Secure the 802.3 compliant Category 5 Ethernet cable to the front RJ45 port. Implement appropriate cable management bends to avoid mechanical tension on the port assembly.
  • Electrical Mitigation and Separation: Keep network lines segregated from motor supply leads and high-power AC conductors within the industrial cabinet to mitigate localized electromagnetic induction.
  • Enclosure Cleanliness: Since the unit utilizes an open-style open-style chassis configuration, maintain ambient surrounding temperatures below 60 Celsius and guard against conductive foreign debris.

Compliance and Certifications

  • ATEX
  • China CCC
  • Australian RCM
  • American Bureau of Shipping
  • Semiconductor Inds Immunit

Official Product Documentation

Access and download the official Allen-Bradley manufacturer publications for this module:

Document Title / Type Publication Number Action
ControlLogix Communication Modules Technical Data 1756-TD003 Download PDF ↗
ControlLogix EtherNet/IP Bridge Module Installation Instructions 1756-IN019 Download PDF ↗
ControlLogix 5580 and 5570 Systems Selection Guide 1756-SG001 Download PDF ↗
ControlLogix 5580 Controllers Product Profile -- Download PDF ↗
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the maximum number of network connections supported by the communication module?
The communication module supports a maximum of 64 TCP connections and up to 128 CIP connections simultaneously, which can be configured for explicit or implicit applications.
What type of cabling infrastructure is specified for the Ethernet interface?
The interface requires an 802.3 compliant shielded or unshielded twisted-pair Category 5 cable connected to its single copper RJ45 port.
What are the precise current draw parameters from the rack backplane?
The communication module draws an operational electrical current of 700mA at 5.1V DC and 3mA at 24V DC from the local chassis backplane.
Reviews

1756-ENBT

Stock & lead time on request

Call
1 su 3

Allen-Bradley 1756-ENBT ControlLogix EtherNet/IP Bridge Module

Only 2 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-ENBT

  • Country of origin:United States

  • Product Type: Communication Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 290g

  • Dimensions: 35 mm x 140 mm x 145 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Allen-Bradley 1756-ENBT is a chassis-based industrial communication module engineered for the ControlLogix hardware architecture. It functions as a dedicated bridge link between localized automation infrastructure and macro-level plant networks, handling explicit messaging and real-time distributed data transfers over EtherNet/IP links. Incorporating 1 standard copper RJ45 socket that handles 10/100 Mbps communication rates over Category 5 network infrastructure, the 1756-ENBT supports 64 TCP/IP connections alongside up to 128 simultaneous CIP connections to execute multi-node monitoring and distributed standard remote IO interfaces.

Employing a standardized open-style enclosure rated to occupy a single slot width inside any standard hardware rack, this communication module uses producer-consumer networking mechanisms to facilitate seamless data distribution across multiple distributed system controllers. Field personnel can perform diagnostic assessments directly via the onboard front digital indicator panel. The circuit framework provides up to 30V continuous operational isolation between the physical network cabling and the backplane logic components to insulate internal automation architectures against transient external electrical surges.

Features

  • Bridges Control Network Architectures: Provides a specialized communication interface linking upstream factory networking layers with standard remote I/O sub-assemblies.
  • Dual Connection Topologies: Features dual capability with support for a maximum of 64 TCP/IP connections alongside 128 physical CIP connection configurations.
  • Integrated Hardware Diagnostics: Front-mounted localized digital indicators simplify system verification by reporting live hardware states and communication errors.
  • Industrial Media Support: Built with a standard 10/100 Mbps copper RJ45 port compatible with shielded or unshielded category 5 twisted-pair media lines.

Applications

  • Remote I/O station integration and localized distributed control rack telemetry.
  • Standardized supervisory control and real-time plant data management links.
  • Inter-chassis processor logic sharing and machine-to-machine data synchronization.
  • Variable frequency drive monitoring and integrated remote peripheral instrumentation data paths.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Catalog Number 1756-ENBT
Sub Brand ControlLogix
Type Communication Module
Interface 1 Copper RJ45 (10/100 Mbps)
Number of Channels 1
Communication Rate 10/100 Mbps
Connections Supported (Max) TCP: 64, CIP: 128
CIP Unconnected Messages 64 + 64 (backplane + Ethernet)
Current Draw 700mA @ 5.1V DC, 3mA @ 24V DC
Power Dissipation 3.7 W
Thermal Dissipation 12.6 btu/h
Isolation Voltage 30V (continuous), basic insulation type, Ethernet network to backplane
Enclosure Type Rating None (open-style)
Slot Width 1
ATEX Temp Code T4
Operating Temperature 0 Celsius to 60 Celsius (32 Fahrenheit to 140 Fahrenheit)
Storage Temperature -40 Celsius to 85 Celsius (-40 Fahrenheit to 185 Fahrenheit)
Relative Humidity 5...95% noncondensing
Vibration 2 G @ 10...500 Hz
Operating Shock 30 G
Non-Operating Shock 50 G

Connections/Interfaces

Connector Pin Function
Ethernet RJ45 Port Category 5 shielded or unshielded twisted pair network connection interface

Installation Guidelines

  • Module Insertion: Align the circuit board edge with the top and bottom channel guides of a free rack slot inside the target chassis. Push firmly inward until the securing mechanism locks completely.
  • Network Media Routing: Secure the 802.3 compliant Category 5 Ethernet cable to the front RJ45 port. Implement appropriate cable management bends to avoid mechanical tension on the port assembly.
  • Electrical Mitigation and Separation: Keep network lines segregated from motor supply leads and high-power AC conductors within the industrial cabinet to mitigate localized electromagnetic induction.
  • Enclosure Cleanliness: Since the unit utilizes an open-style open-style chassis configuration, maintain ambient surrounding temperatures below 60 Celsius and guard against conductive foreign debris.

Compliance and Certifications

  • ATEX
  • China CCC
  • Australian RCM
  • American Bureau of Shipping
  • Semiconductor Inds Immunit

Official Product Documentation

Access and download the official Allen-Bradley manufacturer publications for this module:

Document Title / Type Publication Number Action
ControlLogix Communication Modules Technical Data 1756-TD003 Download PDF ↗
ControlLogix EtherNet/IP Bridge Module Installation Instructions 1756-IN019 Download PDF ↗
ControlLogix 5580 and 5570 Systems Selection Guide 1756-SG001 Download PDF ↗
ControlLogix 5580 Controllers Product Profile -- Download PDF ↗

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1756-ENBT ControlLogix EtherNet/IP Bridge Module

What is the maximum number of network connections supported by the communication module?

The communication module supports a maximum of 64 TCP connections and up to 128 CIP connections simultaneously, which can be configured for explicit or implicit applications.

What type of cabling infrastructure is specified for the Ethernet interface?

The interface requires an 802.3 compliant shielded or unshielded twisted-pair Category 5 cable connected to its single copper RJ45 port.

What are the precise current draw parameters from the rack backplane?

The communication module draws an operational electrical current of 700mA at 5.1V DC and 3mA at 24V DC from the local chassis backplane.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.