Allen-Bradley

Allen-Bradley 1770-KFD PLC-5 DeviceNet RS-232 Communication Interface Module

SKU 1770-KFD

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley
  • Product No.: 1770-KFD
  • Origin United States
  • Product Type: Communication Modules
  • Payment: T/T, Western Union
  • Weight: 0.35 kg
  • Dimensions: 180 x 130 x 60 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The Allen-Bradley 1770-KFD is a portable, standalone DeviceNet RS-232 Communication Interface Module designed to provide personal computers and programming workstations direct serial access to a DeviceNet industrial network. Operating as an external communication gateway, the module bridges standard RS-232 serial ports with DeviceNet field networks, enabling system integrators, control engineers, and maintenance personnel to perform online network monitoring, device configuration, node commissioning, and diagnostic procedures across distributed automation architectures.

Functioning within Allen-Bradley PLC-5, SLC 500, and CompactLogix automation environments, the 1770-KFD facilitates communication either in a point-to-point configuration directly connected to a single field device or across a multi-node DeviceNet trunkline. The module executes local network management routines and protocol conversion between RS-232 framing and DeviceNet CAN-based messaging, allowing software applications such as DeviceNet Manager or RSLinx to interface with scanners, I/O blocks, drives, and intelligent sensors across the network.

Built with a compact desktop enclosure and optional DIN rail mounting brackets, the 1770-KFD features dual power sourcing flexibility. It can operate directly from the 24V DC bus provided by the DeviceNet network connection or via an external 9V DC wall adapter. Status LEDs provide continuous visual feedback for module diagnostics and network bus state, streamlining field service, network troubleshooting, and parameter backup operations.

Features

  • Serial to DeviceNet Protocol Conversion: Converts standard RS-232 serial data frames into DeviceNet CAN-based messages for PC-based commissioning and parameter management.
  • Dual Operation Modes: Supports point-to-point direct configuration with an individual network device as well as full multi-drop access across an active DeviceNet network segment.
  • Flexible Sourcing Options: Operates using power drawn directly from the DeviceNet network cable (11 to 25V DC) or through an external 9V DC power supply adapter.
  • Selectable Communication Baud Rates: Features RS-232 transmission speeds up to 57,600 baud and DeviceNet network data rates selectable at 125k, 250k, and 500k baud.
  • Point-to-Point Power Delivery: Capable of supplying 12V DC power (up to 100 mA) to a connected field device during direct point-to-point setup sessions.
  • Diagnostic LED Indicators: Integrated visual indicators provide real-time status monitoring for module power, operational health, and DeviceNet communication activity.
  • Portable and DIN-Rail Mountable: Lightweight, compact enclosure suitable for benchtop service work or permanent cabinet mounting using included DIN rail adapters.

Applications

  • Field Device Commissioning: Direct point-to-point parameter configuration of DeviceNet smart sensors, motor starters, drives, and remote I/O modules prior to network installation.
  • Network Diagnostics and Monitoring: Online bus monitoring, message traffic inspection, and node address verification using PC-based software like DeviceNet Manager.
  • PLC System Maintenance: Interface point for servicing DeviceNet scanner networks managed by Allen-Bradley PLC-5 (1771-SDN), SLC 500 (1747-SDN), or CompactLogix (1769-SDN) controllers.
  • Parameter Backup and Restore: Uploading and downloading device profiles, node configurations, and operational parameters during field hardware replacements.

Technical Specifications

General

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Model 1770-KFD
Product Type DeviceNet RS-232 Communication Interface Module
Physical Dimensions 13.017 x 8.255 x 2.857 cm (5.125 x 3.25 x 1.125 in)
Weight 156 g (5.5 oz)

Communication Parameters

Parameter Specification
Host Interface Port 9-pin D-shell RS-232 (Female/DTE connection)
Network Interface Port 5-pin unsealed DeviceNet terminal receptacle
RS-232 Baud Rates 1200, 2400, 4800, 9600, 19,200, 38,400, 57,600 baud
DeviceNet Baud Rates 125k, 250k, 500k baud
DeviceNet Power Pass-Through 11 to 25V DC network power

Electrical Requirements

Parameter Specification
External AC Adapter Input 9V DC @ 1 A (via 120V AC or global 90-260V AC wall adapter)
DeviceNet Bus Current Draw 700 mA to 300 mA (11 to 25V DC range)
Auxiliary Output Power (Point-to-Point) 12V DC ±5% @ 100 mA max (for target field device)

Environmental

Parameter Specification
Operating Temperature 0 to 50 degC (32 to 122 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5% to 95% non-condensing

Connections / Interfaces

Interface Function
9-pin D-shell RS-232 Connector Connects via 9-pin null-modem serial cable to PC COM port or modem
5-pin Unsealed DeviceNet Connector Connects to DeviceNet trunkline or drop cable (V-, CAN_L, Shield, CAN_H, V+)
External Power Jack Receptacle for 9V DC external AC wall power adapter
Power Selector Switch Toggles operational power state between External AC Adapter and Network Power

Installation Guidelines

  1. Safety Precaution: Verify that all electrical power sources are disconnected or de-energized according to industrial safety protocols before modifying control panel wiring.
  2. Mounting: Use the module as a portable desktop unit, or install the provided DIN rail mounting brackets using the four mounting screws to attach the module onto a standard 35 mm DIN rail inside a enclosure.
  3. Serial Cable Connection: Connect the 9-pin D-shell RS-232 port on the module to an available serial COM port on the host workstation using a standard 9-pin null-modem cable.
  4. DeviceNet Bus Connection: Wire the 5-pin unsealed DeviceNet terminal connector to the network drop cable, ensuring proper pin assignment matching for signal (CAN_H, CAN_L), power (V+, V-), and drain/shield lines.
  5. Power Source Verification:
    • For network-powered operation, ensure the active DeviceNet bus provides between 11V DC and 25V DC across the V+ and V- terminals. Note that active network power overrides external power input.
    • For standalone benchtop setup, connect the approved 9V DC wall adapter into the DC power jack.
  6. Grounding: Ensure proper shielding and signal grounding principles are maintained along the DeviceNet network drop line to prevent noise interference.

Configuration / Commissioning / Replacement

Configuration Guidelines

  • Install the appropriate 1770-KFD driver software or serial driver within RSLinx / DeviceNet Manager on the PC host.
  • Match the driver serial baud rate setting in software to the physical switch/software selection configured on the 1770-KFD module (up to 57,600 baud).
  • Ensure the target DeviceNet network transmission rate (125k, 250k, or 500k baud) matches the operational baud rate of all nodes connected to the bus.

Commissioning & Diagnostics

  • Observe the module status LEDs upon powering the unit. Verify stable power illumination and normal communication toggling on both serial and network lines.
  • Perform node detection scanning from the workstation software to confirm online visibility of connected DeviceNet field devices or PLC scanner modules (such as 1771-SDN, 1747-SDN, or 1769-SDN).

Replacement Recommendations

  • When replacing an existing 1770-KFD interface module, confirm that serial driver configurations and baud rate selections in RSLinx or host software match previous system parameters.
  • Disconnect the DeviceNet terminal block from the old module and plug it directly into the replacement unit without altering individual wire terminations.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Allen-Bradley 1770-KFD module?
The module serves as a portable serial communication gateway that connects a host computer's RS-232 port to a DeviceNet network, enabling online device configuration, network diagnostics, parameter monitoring, and commissioning.
How is power supplied to the 1770-KFD interface module?
The module can be powered directly from the DeviceNet bus (11 to 25V DC) via the 5-pin network connector or through an external 9V DC AC wall power supply adapter.
Which baud rates are supported by the 1770-KFD interface?
The module supports RS-232 serial communication rates from 1200 up to 57,600 baud, and standard DeviceNet network transmission rates of 125k, 250k, and 500k baud.
Can the 1770-KFD power a field device during point-to-point configuration?
Yes, in a direct point-to-point configuration, the module can supply up to 100 mA at 12V DC (±5%) to power a connected field device for configuration purposes.
Reviews

1770-KFD

Stock & lead time on request

Call
1 su 1

Allen-Bradley 1770-KFD PLC-5 DeviceNet RS-232 Communication Interface Module

Only 14 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1770-KFD

  • Country of origin:United States

  • Product Type: Communication Modules

  • Payment: T/T, Western Union

  • Weight: 350g

  • Dimensions: 180 x 130 x 60 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Allen-Bradley 1770-KFD is a portable, standalone DeviceNet RS-232 Communication Interface Module designed to provide personal computers and programming workstations direct serial access to a DeviceNet industrial network. Operating as an external communication gateway, the module bridges standard RS-232 serial ports with DeviceNet field networks, enabling system integrators, control engineers, and maintenance personnel to perform online network monitoring, device configuration, node commissioning, and diagnostic procedures across distributed automation architectures.

Functioning within Allen-Bradley PLC-5, SLC 500, and CompactLogix automation environments, the 1770-KFD facilitates communication either in a point-to-point configuration directly connected to a single field device or across a multi-node DeviceNet trunkline. The module executes local network management routines and protocol conversion between RS-232 framing and DeviceNet CAN-based messaging, allowing software applications such as DeviceNet Manager or RSLinx to interface with scanners, I/O blocks, drives, and intelligent sensors across the network.

Built with a compact desktop enclosure and optional DIN rail mounting brackets, the 1770-KFD features dual power sourcing flexibility. It can operate directly from the 24V DC bus provided by the DeviceNet network connection or via an external 9V DC wall adapter. Status LEDs provide continuous visual feedback for module diagnostics and network bus state, streamlining field service, network troubleshooting, and parameter backup operations.

Features

  • Serial to DeviceNet Protocol Conversion: Converts standard RS-232 serial data frames into DeviceNet CAN-based messages for PC-based commissioning and parameter management.
  • Dual Operation Modes: Supports point-to-point direct configuration with an individual network device as well as full multi-drop access across an active DeviceNet network segment.
  • Flexible Sourcing Options: Operates using power drawn directly from the DeviceNet network cable (11 to 25V DC) or through an external 9V DC power supply adapter.
  • Selectable Communication Baud Rates: Features RS-232 transmission speeds up to 57,600 baud and DeviceNet network data rates selectable at 125k, 250k, and 500k baud.
  • Point-to-Point Power Delivery: Capable of supplying 12V DC power (up to 100 mA) to a connected field device during direct point-to-point setup sessions.
  • Diagnostic LED Indicators: Integrated visual indicators provide real-time status monitoring for module power, operational health, and DeviceNet communication activity.
  • Portable and DIN-Rail Mountable: Lightweight, compact enclosure suitable for benchtop service work or permanent cabinet mounting using included DIN rail adapters.

Applications

  • Field Device Commissioning: Direct point-to-point parameter configuration of DeviceNet smart sensors, motor starters, drives, and remote I/O modules prior to network installation.
  • Network Diagnostics and Monitoring: Online bus monitoring, message traffic inspection, and node address verification using PC-based software like DeviceNet Manager.
  • PLC System Maintenance: Interface point for servicing DeviceNet scanner networks managed by Allen-Bradley PLC-5 (1771-SDN), SLC 500 (1747-SDN), or CompactLogix (1769-SDN) controllers.
  • Parameter Backup and Restore: Uploading and downloading device profiles, node configurations, and operational parameters during field hardware replacements.

Technical Specifications

General

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Model 1770-KFD
Product Type DeviceNet RS-232 Communication Interface Module
Physical Dimensions 13.017 x 8.255 x 2.857 cm (5.125 x 3.25 x 1.125 in)
Weight 156 g (5.5 oz)

Communication Parameters

Parameter Specification
Host Interface Port 9-pin D-shell RS-232 (Female/DTE connection)
Network Interface Port 5-pin unsealed DeviceNet terminal receptacle
RS-232 Baud Rates 1200, 2400, 4800, 9600, 19,200, 38,400, 57,600 baud
DeviceNet Baud Rates 125k, 250k, 500k baud
DeviceNet Power Pass-Through 11 to 25V DC network power

Electrical Requirements

Parameter Specification
External AC Adapter Input 9V DC @ 1 A (via 120V AC or global 90-260V AC wall adapter)
DeviceNet Bus Current Draw 700 mA to 300 mA (11 to 25V DC range)
Auxiliary Output Power (Point-to-Point) 12V DC ±5% @ 100 mA max (for target field device)

Environmental

Parameter Specification
Operating Temperature 0 to 50 degC (32 to 122 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5% to 95% non-condensing

Connections / Interfaces

Interface Function
9-pin D-shell RS-232 Connector Connects via 9-pin null-modem serial cable to PC COM port or modem
5-pin Unsealed DeviceNet Connector Connects to DeviceNet trunkline or drop cable (V-, CAN_L, Shield, CAN_H, V+)
External Power Jack Receptacle for 9V DC external AC wall power adapter
Power Selector Switch Toggles operational power state between External AC Adapter and Network Power

Installation Guidelines

  1. Safety Precaution: Verify that all electrical power sources are disconnected or de-energized according to industrial safety protocols before modifying control panel wiring.
  2. Mounting: Use the module as a portable desktop unit, or install the provided DIN rail mounting brackets using the four mounting screws to attach the module onto a standard 35 mm DIN rail inside a enclosure.
  3. Serial Cable Connection: Connect the 9-pin D-shell RS-232 port on the module to an available serial COM port on the host workstation using a standard 9-pin null-modem cable.
  4. DeviceNet Bus Connection: Wire the 5-pin unsealed DeviceNet terminal connector to the network drop cable, ensuring proper pin assignment matching for signal (CAN_H, CAN_L), power (V+, V-), and drain/shield lines.
  5. Power Source Verification:
    • For network-powered operation, ensure the active DeviceNet bus provides between 11V DC and 25V DC across the V+ and V- terminals. Note that active network power overrides external power input.
    • For standalone benchtop setup, connect the approved 9V DC wall adapter into the DC power jack.
  6. Grounding: Ensure proper shielding and signal grounding principles are maintained along the DeviceNet network drop line to prevent noise interference.

Configuration / Commissioning / Replacement

Configuration Guidelines

  • Install the appropriate 1770-KFD driver software or serial driver within RSLinx / DeviceNet Manager on the PC host.
  • Match the driver serial baud rate setting in software to the physical switch/software selection configured on the 1770-KFD module (up to 57,600 baud).
  • Ensure the target DeviceNet network transmission rate (125k, 250k, or 500k baud) matches the operational baud rate of all nodes connected to the bus.

Commissioning & Diagnostics

  • Observe the module status LEDs upon powering the unit. Verify stable power illumination and normal communication toggling on both serial and network lines.
  • Perform node detection scanning from the workstation software to confirm online visibility of connected DeviceNet field devices or PLC scanner modules (such as 1771-SDN, 1747-SDN, or 1769-SDN).

Replacement Recommendations

  • When replacing an existing 1770-KFD interface module, confirm that serial driver configurations and baud rate selections in RSLinx or host software match previous system parameters.
  • Disconnect the DeviceNet terminal block from the old module and plug it directly into the replacement unit without altering individual wire terminations.
Loading product navigation…

What is the primary function of the Allen-Bradley 1770-KFD module?

The module serves as a portable serial communication gateway that connects a host computer's RS-232 port to a DeviceNet network, enabling online device configuration, network diagnostics, parameter monitoring, and commissioning.

How is power supplied to the 1770-KFD interface module?

The module can be powered directly from the DeviceNet bus (11 to 25V DC) via the 5-pin network connector or through an external 9V DC AC wall power supply adapter.

Which baud rates are supported by the 1770-KFD interface?

The module supports RS-232 serial communication rates from 1200 up to 57,600 baud, and standard DeviceNet network transmission rates of 125k, 250k, and 500k baud.

Can the 1770-KFD power a field device during point-to-point configuration?

Yes, in a direct point-to-point configuration, the module can supply up to 100 mA at 12V DC (±5%) to power a connected field device for configuration purposes.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Filtrare i segnali PLC rumorosi senza nascondere i guasti reali

Il filtraggio dell’input può stabilizzare i dati del PLC, ma un’eccessiva attenuazione ritarda gli allarmi e maschera i cambiamenti del processo. Scopri come diagnosticare il rumore, scegliere filtri...

SCR o PWM? Scegliere un azionamento per motori CC a spazzole

I sistemi di azionamento SCR e PWM regolano i motori CC a spazzole in modi diversi. Questo confronto analizza la qualità della coppia, l’intervallo di velocità, l’inversione, la frenatura, il rumore...

Come gli inverter industriali generano CA da un bus CC

Gli inverter industriali sintetizzano corrente alternata controllabile da un bus in corrente continua tramite la commutazione e il filtraggio dei semiconduttori. Questa guida illustra i ponti H, la...

Controllo della forza del robot: dal rilevamento del contatto alla stabilità del processo

Il controllo della forza consente a un robot di adattarsi al contatto invece di seguire esclusivamente la posizione. Questa guida confronta gli approcci al rilevamento, le modalità di controllo, i...

Quando la logica a livello di sensore è utile e quando nasconde i rischi

I sensori configurabili possono eseguire decisioni su finestre, latch, ritardi e logica booleana prima che i dati raggiungano un PLC. Il vantaggio è una risposta locale più rapida; il rischio...

Collegamento di GX Simulator a Factory I/O tramite OPC

Una configurazione stabile di messa in servizio virtuale Mitsubishi richiede più della semplice corrispondenza degli indirizzi. Questa guida spiega il percorso dei dati GX Simulator–OPC–Factory I/O,...