Description

The KL9505 is a 5 V DC power supply terminal designed to provide a regulated voltage for peripheral devices within the Beckhoff Bus Terminal system. This module converts a 24 V DC input into a stabilized 5 V DC output, ensuring reliable power delivery for sensitive electronics. It is engineered for industrial environments, featuring an integrated overcurrent LED for status monitoring and protection against short circuits.

Features

  • Stabilized 5 V DC output voltage
  • Integrated overcurrent monitoring with LED indicator
  • Short-circuit proof design
  • Pluggable wiring interface for KSxxxx series compatibility
  • Compact DIN rail mountable form factor

Applications

  • Powering auxiliary 5 V sensors or transducers
  • Local supply for communication interfaces
  • General-purpose low-voltage DC power distribution in automation cabinets

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model KL9505
Input Voltage 24 V DC (-15 %/+20 %)
Output Voltage 5 V DC ±1 %
Output Current 0.5 A
Residual Ripple < 5 mV
Short-Circuit Proof Yes
Weight Approx. 65 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
Protection Rating IP20

Installation Guidelines

  • DIN Rail Mounting: The module is designed for standard DIN rail installation. Ensure it is securely clicked into place to maintain proper electrical contact with the bus system.
  • Wiring: Use pluggable wiring consistent with KSxxxx series requirements. Ensure correct polarity of the 24 V DC input supply.
  • Cooling: Maintain adequate clearance around the module to allow for natural convection cooling, especially when operating near the upper limit of the temperature range.
  • Protection: Adhere to local EMC regulations (EN 61000-6-2/EN 61000-6-4) during cable routing to minimize noise interference.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • Vibration/Shock: Conforms to EN 60068-2-6 / EN 60068-2-27
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the KL9505 terminal?
The KL9505 is a power supply terminal that converts a 24 V DC input into a stabilized 5 V DC output for use within the Beckhoff Bus Terminal system.
Does the module provide protection against short circuits?
Yes, the module is short-circuit proof and includes an integrated overcurrent LED to indicate fault conditions.
What is the maximum output current for this device?
The maximum output current for the KL9505 is 0.5 A.
What are the environmental operating limits for this module?
The module operates within a temperature range of 0 to +55 degC and supports up to 95% relative humidity without condensation.
Reviews

KL9505

Stock &amp; lead time on request

Call
1 su 1

Beckhoff KL9505 Bus Terminal Power Supply Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL9505

  • Country of origin:Germany

  • Product Type: Power supply terminal 5 V DC

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The KL9505 is a 5 V DC power supply terminal designed to provide a regulated voltage for peripheral devices within the Beckhoff Bus Terminal system. This module converts a 24 V DC input into a stabilized 5 V DC output, ensuring reliable power delivery for sensitive electronics. It is engineered for industrial environments, featuring an integrated overcurrent LED for status monitoring and protection against short circuits.

Features

  • Stabilized 5 V DC output voltage
  • Integrated overcurrent monitoring with LED indicator
  • Short-circuit proof design
  • Pluggable wiring interface for KSxxxx series compatibility
  • Compact DIN rail mountable form factor

Applications

  • Powering auxiliary 5 V sensors or transducers
  • Local supply for communication interfaces
  • General-purpose low-voltage DC power distribution in automation cabinets

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model KL9505
Input Voltage 24 V DC (-15 %/+20 %)
Output Voltage 5 V DC ±1 %
Output Current 0.5 A
Residual Ripple < 5 mV
Short-Circuit Proof Yes
Weight Approx. 65 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
Protection Rating IP20

Installation Guidelines

  • DIN Rail Mounting: The module is designed for standard DIN rail installation. Ensure it is securely clicked into place to maintain proper electrical contact with the bus system.
  • Wiring: Use pluggable wiring consistent with KSxxxx series requirements. Ensure correct polarity of the 24 V DC input supply.
  • Cooling: Maintain adequate clearance around the module to allow for natural convection cooling, especially when operating near the upper limit of the temperature range.
  • Protection: Adhere to local EMC regulations (EN 61000-6-2/EN 61000-6-4) during cable routing to minimize noise interference.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • Vibration/Shock: Conforms to EN 60068-2-6 / EN 60068-2-27

What is the primary function of the KL9505 terminal?

The KL9505 is a power supply terminal that converts a 24 V DC input into a stabilized 5 V DC output for use within the Beckhoff Bus Terminal system.

Does the module provide protection against short circuits?

Yes, the module is short-circuit proof and includes an integrated overcurrent LED to indicate fault conditions.

What is the maximum output current for this device?

The maximum output current for the KL9505 is 0.5 A.

What are the environmental operating limits for this module?

The module operates within a temperature range of 0 to +55 degC and supports up to 95% relative humidity without condensation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...