Bently Nevada

Bently Nevada 136180-01+136188-01 3500/92 Communication Gateway Module + Ethernet/RS232 Modbus I/O Module

SKU 136180-01+136188-01

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada
  • Product No.: 136180-01+136188-01
  • Origin United States
  • Product Type: Communication Gateway Modules
  • Payment: T/T, Western Union
  • Weight: 1.26 kg
  • Dimensions: 241.3 mm x 48.8 mm x 241.3 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 136180-01+136188-01 3500/92 Communication Gateway Module + Ethernet/RS232 Modbus I/O Module

Quantità

Product Description

Description

The 136180-01+136188-01 combination consists of the 3500/92 Communication Gateway Module main card (136180-01) and the associated Ethernet/RS232 Modbus I/O Module rear card (136188-01). This module set establishes digital communication links between the Bently Nevada 3500 Machinery Protection System and external plant automation platforms.

The gateway collects static measurement data, system event lists, and alarm statuses directly from the 3500 rack backplane and translates the information into standard Modbus protocols. Utilizing the 136188-01 rear I/O card, it offers hardware interfaces for Modbus communication over Ethernet networks and point-to-point RS232 serial connections. Plant operators use the 136180-01+136188-01 to integrate vibration monitoring values, thrust positioning, and system diagnostic events directly into Distributed Control Systems (DCS), Programmable Logic Controllers (PLC), and Human-Machine Interfaces (HMI).

Features

  • Integrates the 3500/92 main monitor board with an Ethernet/RS232 rear I/O card.
  • Supports Modbus TCP/IP communication over Ethernet and Modbus RTU/ASCII over serial connections.
  • Transmits static values, alarm events, and system statuses across redundant digital channels.
  • Configurable Modbus register mapping via 3500 System Rack Configuration Software.
  • Maintains galvanic isolation between field interfaces and the internal rack logic.

Applications

  • Integration of 3500 machinery protection data into DCS and PLC networks
  • Remote monitoring of turbomachinery static vibration and position parameters
  • Industrial automation control loops requiring real-time machinery state data
  • Plant-wide condition monitoring and data historian integration

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Main Card Part Number 136180-01
I/O Module Part Number 136188-01
Module Type Communication Gateway Module + Ethernet/RS232 Modbus I/O Module
Protocols Modbus TCP/IP, Modbus RTU, Modbus ASCII
Ethernet Port 10BASE-T / 100BASE-TX
Serial Port RS232 (Configurable baud rate)
Operating Temperature -30 degC to +65 degC (-22 degF to +149 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, noncondensing
Rack Space 1 full-height front slot (Main Card) + 1 full-height rear slot (I/O Card)

Connections and Interfaces

Port / Terminal Function
RJ45 Ethernet Modbus TCP/IP Network Connection
RS232 Serial Port Serial Modbus RTU / ASCII Connection

Installation Guidelines

  • Install the 136180-01 main card into a full-height slot on the front of the 3500 rack.
  • Mount the 136188-01 I/O module in the rear of the rack directly behind the 136180-01 main card.
  • Ensure cable shields are grounded according to system installation practices to minimize EMI/RFI noise.
  • Configure Modbus slave address, baud rate, and network IP settings through the 3500 System Configuration Software prior to commissioning.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What protocols are supported by the communication module?
The module supports Modbus TCP/IP via its Ethernet interface as well as Modbus RTU and Modbus ASCII over its RS232 serial interface.
Where is the I/O module installed in the rack?
The I/O module installs into a full-height slot at the rear of the 3500 rack directly behind the main communication gateway card.
How are the communication settings configured on the device?
All network settings, serial baud rates, and Modbus register maps are configured using the 3500 System Rack Configuration Software.
Reviews

136180-01+136188-01

Stock & lead time on request

Call
1 su 1

Bently Nevada 136180-01+136188-01 3500/92 Communication Gateway Module + Ethernet/RS232 Modbus I/O Module

Only 7 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 136180-01+136188-01

  • Country of origin:United States

  • Product Type: Communication Gateway Modules

  • Payment: T/T, Western Union

  • Weight: 1260g

  • Dimensions: 241.3 mm x 48.8 mm x 241.3 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The 136180-01+136188-01 combination consists of the 3500/92 Communication Gateway Module main card (136180-01) and the associated Ethernet/RS232 Modbus I/O Module rear card (136188-01). This module set establishes digital communication links between the Bently Nevada 3500 Machinery Protection System and external plant automation platforms.

The gateway collects static measurement data, system event lists, and alarm statuses directly from the 3500 rack backplane and translates the information into standard Modbus protocols. Utilizing the 136188-01 rear I/O card, it offers hardware interfaces for Modbus communication over Ethernet networks and point-to-point RS232 serial connections. Plant operators use the 136180-01+136188-01 to integrate vibration monitoring values, thrust positioning, and system diagnostic events directly into Distributed Control Systems (DCS), Programmable Logic Controllers (PLC), and Human-Machine Interfaces (HMI).

Features

  • Integrates the 3500/92 main monitor board with an Ethernet/RS232 rear I/O card.
  • Supports Modbus TCP/IP communication over Ethernet and Modbus RTU/ASCII over serial connections.
  • Transmits static values, alarm events, and system statuses across redundant digital channels.
  • Configurable Modbus register mapping via 3500 System Rack Configuration Software.
  • Maintains galvanic isolation between field interfaces and the internal rack logic.

Applications

  • Integration of 3500 machinery protection data into DCS and PLC networks
  • Remote monitoring of turbomachinery static vibration and position parameters
  • Industrial automation control loops requiring real-time machinery state data
  • Plant-wide condition monitoring and data historian integration

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Main Card Part Number 136180-01
I/O Module Part Number 136188-01
Module Type Communication Gateway Module + Ethernet/RS232 Modbus I/O Module
Protocols Modbus TCP/IP, Modbus RTU, Modbus ASCII
Ethernet Port 10BASE-T / 100BASE-TX
Serial Port RS232 (Configurable baud rate)
Operating Temperature -30 degC to +65 degC (-22 degF to +149 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, noncondensing
Rack Space 1 full-height front slot (Main Card) + 1 full-height rear slot (I/O Card)

Connections and Interfaces

Port / Terminal Function
RJ45 Ethernet Modbus TCP/IP Network Connection
RS232 Serial Port Serial Modbus RTU / ASCII Connection

Installation Guidelines

  • Install the 136180-01 main card into a full-height slot on the front of the 3500 rack.
  • Mount the 136188-01 I/O module in the rear of the rack directly behind the 136180-01 main card.
  • Ensure cable shields are grounded according to system installation practices to minimize EMI/RFI noise.
  • Configure Modbus slave address, baud rate, and network IP settings through the 3500 System Configuration Software prior to commissioning.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 136180-01+136188-01 3500/92 Communication Gateway Module + Ethernet/RS232 Modbus I/O Module

What protocols are supported by the communication module?

The module supports Modbus TCP/IP via its Ethernet interface as well as Modbus RTU and Modbus ASCII over its RS232 serial interface.

Where is the I/O module installed in the rack?

The I/O module installs into a full-height slot at the rear of the 3500 rack directly behind the main communication gateway card.

How are the communication settings configured on the device?

All network settings, serial baud rates, and Modbus register maps are configured using the 3500 System Rack Configuration Software.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.