Danfoss

Danfoss 060G1372 Industrial Compact Pressure Transmitter

SKU 060G1372

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss
  • Product No.: 060G1372
  • Origin United States
  • Product Type: Controles Industriales Pressure Transmitter
  • Payment: T/T, Western Union
  • Weight: 1.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The 060G1372 (060G1372) is a robust pressure transmitter engineered for high-precision control in heavy industrial automation. Tailored for deployment in commercial boiler systems, cooling towers, hydraulic lines, and municipal water distribution networks, this field-tested instrument provides stable analog current feedback. By continuously monitoring pressure metrics and transmitting data to a central PLC or Distributed Control System (DCS), the sensor enables real-time optimization of pump speeds and valve positions. This precision tracking effectively minimizes fluid hammer risks, prevents cavitation anomalies, and helps avoid unpredicted plant shutdowns, ensuring maximum equipment efficiency.

Technical Configuration

The hardware features an acid-resistant stainless steel body containing a piezoresistive sensing element designed to resist mechanical shock and cyclic stress. To ensure long-term stability, the internal electronics utilize a fixed calibration framework that isolates the sensor from drift caused by ambient mechanical resonance. Integrated diagnostics enforce strict signal clipping thresholds between 3.6 mA and 22.4 mA, allowing automation controllers to instantly distinguish valid pressure fluctuations from wiring faults or signal shorts. The internal control board is further protected by an IP65-rated enclosure, shielding the circuitry from ambient humidity, splashing process water, and airborne particulates.

Technical Specifications

Feature Specification
Model 060G1372
Brand Danfoss
Pressure Range 0 to 40 bar
Output Loop 4-20 mA
Precision +/- 0.5% (Typical) / +/- 1.0% (Max)
Overload Pressure 100 bar
Process Thread G 1/4 Male (EN 837)
Operating Temp -40 to 100 deg C
Electrical Connector Pg 11 Angular
Ingress Protection IP65
Weight Approx 1.5 kg

FAQs

How do the integrated signal clipping parameters assist with diagnostics?

The sensor bounds its output; values shifting to 3.6 mA or 22.4 mA signify a fault. Because these values reside outside the standard 4-20 mA band, the supervising PLC can flag a field component defect without mistaking it for a legitimate process pressure change.

Does this gauge transmitter require atmospheric venting?

Yes. As a relative gauge transmitter, it references ambient atmospheric pressure. The reference channel is integrated into the connector structure, allowing the sensor to compensate for barometric fluctuations while maintaining an IP65 environmental seal.

Can the zero point be adjusted in the field?

No. This instrument utilizes a laser-welded, factory-sealed architecture with no mechanical trim potentiometers. This fixed design prevents calibration drift caused by continuous vibration and eliminates the risk of unauthorized field adjustments.

Mechanical Installation & Wiring Protocols

  • Process Port Mounting: Thread the G 1/4 male fitting into a port counter-bored to EN 837 specifications. Use a calibrated torque wrench on the 27 mm hex base to tighten the transmitter to 30-35 Nm. Do not rotate the upper cylindrical body by hand, as this risks breaking internal seal joints.

  • Terminal Interface: Terminate the positive power lead to Pin 1 and the negative return path to Pin 2 of the Pg 11 angular connector. Ensure the perimeter rubber seal is seated flush inside the connector cap before tightening the retaining screw to maintain the IP65 environmental seal.

  • Acoustic and Shock Mitigation: In systems with fast-cycling hydraulic loops or high-frequency piston pumps, install an upstream dampening orifice or siphon loop. While the sensor accommodates 100 bar surges, continuous exposure to cavitation peaks can degrade the structural integrity of the internal diaphragm.


 

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

060G1372

Stock & lead time on request

Call
1 su 1

Danfoss 060G1372 Industrial Compact Pressure Transmitter

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 060G1372

  • Country of origin:United States

  • Product Type: Controles Industriales Pressure Transmitter

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The 060G1372 (060G1372) is a robust pressure transmitter engineered for high-precision control in heavy industrial automation. Tailored for deployment in commercial boiler systems, cooling towers, hydraulic lines, and municipal water distribution networks, this field-tested instrument provides stable analog current feedback. By continuously monitoring pressure metrics and transmitting data to a central PLC or Distributed Control System (DCS), the sensor enables real-time optimization of pump speeds and valve positions. This precision tracking effectively minimizes fluid hammer risks, prevents cavitation anomalies, and helps avoid unpredicted plant shutdowns, ensuring maximum equipment efficiency.

Technical Configuration

The hardware features an acid-resistant stainless steel body containing a piezoresistive sensing element designed to resist mechanical shock and cyclic stress. To ensure long-term stability, the internal electronics utilize a fixed calibration framework that isolates the sensor from drift caused by ambient mechanical resonance. Integrated diagnostics enforce strict signal clipping thresholds between 3.6 mA and 22.4 mA, allowing automation controllers to instantly distinguish valid pressure fluctuations from wiring faults or signal shorts. The internal control board is further protected by an IP65-rated enclosure, shielding the circuitry from ambient humidity, splashing process water, and airborne particulates.

Technical Specifications

Feature Specification
Model 060G1372
Brand Danfoss
Pressure Range 0 to 40 bar
Output Loop 4-20 mA
Precision +/- 0.5% (Typical) / +/- 1.0% (Max)
Overload Pressure 100 bar
Process Thread G 1/4 Male (EN 837)
Operating Temp -40 to 100 deg C
Electrical Connector Pg 11 Angular
Ingress Protection IP65
Weight Approx 1.5 kg

FAQs

How do the integrated signal clipping parameters assist with diagnostics?

The sensor bounds its output; values shifting to 3.6 mA or 22.4 mA signify a fault. Because these values reside outside the standard 4-20 mA band, the supervising PLC can flag a field component defect without mistaking it for a legitimate process pressure change.

Does this gauge transmitter require atmospheric venting?

Yes. As a relative gauge transmitter, it references ambient atmospheric pressure. The reference channel is integrated into the connector structure, allowing the sensor to compensate for barometric fluctuations while maintaining an IP65 environmental seal.

Can the zero point be adjusted in the field?

No. This instrument utilizes a laser-welded, factory-sealed architecture with no mechanical trim potentiometers. This fixed design prevents calibration drift caused by continuous vibration and eliminates the risk of unauthorized field adjustments.

Mechanical Installation & Wiring Protocols

  • Process Port Mounting: Thread the G 1/4 male fitting into a port counter-bored to EN 837 specifications. Use a calibrated torque wrench on the 27 mm hex base to tighten the transmitter to 30-35 Nm. Do not rotate the upper cylindrical body by hand, as this risks breaking internal seal joints.

  • Terminal Interface: Terminate the positive power lead to Pin 1 and the negative return path to Pin 2 of the Pg 11 angular connector. Ensure the perimeter rubber seal is seated flush inside the connector cap before tightening the retaining screw to maintain the IP65 environmental seal.

  • Acoustic and Shock Mitigation: In systems with fast-cycling hydraulic loops or high-frequency piston pumps, install an upstream dampening orifice or siphon loop. While the sensor accommodates 100 bar surges, continuous exposure to cavitation peaks can degrade the structural integrity of the internal diaphragm.


 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.