Danfoss

Danfoss 060G2108 AKS 33 Industrial Pressure Transmitter

SKU 060G2108

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss
  • Product No.: 060G2108
  • Origin United States
  • Product Type: Pressure Transmitter | AKS 33
  • Payment: T/T, Western Union
  • Weight: 0.168 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The 060G2108 (060G2108) is a high-precision pressure transmitter from the Danfoss AKS 33 series, specifically engineered for demanding HVAC and refrigeration applications. Designed to provide reliable feedback in industrial cooling systems, heat pumps, and process control networks, this transmitter converts pressure levels into a standardized 4-20 mA analog signal. By ensuring accurate, real-time pressure monitoring for PLCs and supervisory control systems, the AKS 33 helps maintain optimal system efficiency, prevents compressor damage from extreme pressure conditions, and reduces operational downtime through consistent diagnostic feedback.

Technical Configuration

The AKS 33 utilizes a proven sensing technology that delivers high-performance monitoring in a compact, durable package. The device features a sealed gauge pressure reference, which protects the internal sensing element from the ingress of moisture or corrosive elements common in industrial environments. With an IP65-rated angular connector conforming to EN 175301-803-A, the transmitter is protected against dust and splashing water, making it suitable for varied installation positions within mechanical rooms or plant floors. The electronics are optimized for operation across a wide temperature range, ensuring signal stability even in environments where ambient and medium temperatures fluctuate significantly.

Technical Specifications

Feature Specification
Model 060G2108 (AKS 33)
Brand Danfoss
Output Signal 4-20 mA
Pressure Reference Sealed gauge
Overload Pressure 33 bar (479 psi)
Electrical Connector Angular (EN 175301-803-A)
Operating Temp -40 to 85 deg C
Medium Temp -40 to 85 deg C
Compensated Temp -30 to 40 deg C
Ingress Protection IP65
Weight Approx 0.17 kg

FAQs

What is the advantage of the "sealed gauge" reference?

The sealed gauge design references a vacuum-sealed internal cavity. This prevents humidity or contaminants from entering the internal pressure sensing chamber, ensuring accuracy and longevity in harsh or humid industrial environments.

Is this transmitter compatible with standard HVAC control systems?

Yes, the AKS 33 produces a standard 4-20 mA output, making it fully compatible with the vast majority of industrial PLCs, HVAC controllers, and building management systems (BMS).

Does the transmitter require periodic recalibration?

The AKS 33 is designed for long-term stability and is factory-calibrated. Under normal operating conditions, it maintains its accuracy specifications over a long service life, though periodic verification against system standards is recommended based on your site's safety requirements.

What should I do if the connector is exposed to moisture?

While the angular connector provides an IP65 rating when properly seated and tightened, ensure that the rubber gasket is intact and that the screw is fully secured. If moisture ingress is suspected, inspect the terminal contacts for corrosion immediately.

Installation and Operational Guidelines

  • Mechanical Seating: When installing the transmitter, ensure that the process connection is free of debris. Use a suitable wrench on the designated flats of the transmitter body to tighten. Avoid using the electrical connector housing as a leverage point, as this can damage the internal components or the connector seal.

  • Electrical Termination: Follow the EN 175301-803-A standard for wiring. Ensure that the cable gland is tightened sufficiently to prevent cable strain and to maintain the IP65 ingress protection rating. Use shielded cabling if the transmitter is installed in areas with significant electromagnetic interference from motors or frequency drives.

  • Thermal Management: While the transmitter is rated for temperatures up to 85 deg C, avoid mounting it in direct contact with excessively hot surfaces (e.g., uninsulated steam piping) that could cause the ambient temperature to exceed its rated limits, as this may cause premature electronic drift or failure.

 

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

060G2108

Stock & lead time on request

Call
1 su 1

Danfoss 060G2108 AKS 33 Industrial Pressure Transmitter

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 060G2108

  • Country of origin:United States

  • Product Type: Pressure Transmitter | AKS 33

  • Payment: T/T, Western Union

  • Weight: 168g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The 060G2108 (060G2108) is a high-precision pressure transmitter from the Danfoss AKS 33 series, specifically engineered for demanding HVAC and refrigeration applications. Designed to provide reliable feedback in industrial cooling systems, heat pumps, and process control networks, this transmitter converts pressure levels into a standardized 4-20 mA analog signal. By ensuring accurate, real-time pressure monitoring for PLCs and supervisory control systems, the AKS 33 helps maintain optimal system efficiency, prevents compressor damage from extreme pressure conditions, and reduces operational downtime through consistent diagnostic feedback.

Technical Configuration

The AKS 33 utilizes a proven sensing technology that delivers high-performance monitoring in a compact, durable package. The device features a sealed gauge pressure reference, which protects the internal sensing element from the ingress of moisture or corrosive elements common in industrial environments. With an IP65-rated angular connector conforming to EN 175301-803-A, the transmitter is protected against dust and splashing water, making it suitable for varied installation positions within mechanical rooms or plant floors. The electronics are optimized for operation across a wide temperature range, ensuring signal stability even in environments where ambient and medium temperatures fluctuate significantly.

Technical Specifications

Feature Specification
Model 060G2108 (AKS 33)
Brand Danfoss
Output Signal 4-20 mA
Pressure Reference Sealed gauge
Overload Pressure 33 bar (479 psi)
Electrical Connector Angular (EN 175301-803-A)
Operating Temp -40 to 85 deg C
Medium Temp -40 to 85 deg C
Compensated Temp -30 to 40 deg C
Ingress Protection IP65
Weight Approx 0.17 kg

FAQs

What is the advantage of the "sealed gauge" reference?

The sealed gauge design references a vacuum-sealed internal cavity. This prevents humidity or contaminants from entering the internal pressure sensing chamber, ensuring accuracy and longevity in harsh or humid industrial environments.

Is this transmitter compatible with standard HVAC control systems?

Yes, the AKS 33 produces a standard 4-20 mA output, making it fully compatible with the vast majority of industrial PLCs, HVAC controllers, and building management systems (BMS).

Does the transmitter require periodic recalibration?

The AKS 33 is designed for long-term stability and is factory-calibrated. Under normal operating conditions, it maintains its accuracy specifications over a long service life, though periodic verification against system standards is recommended based on your site's safety requirements.

What should I do if the connector is exposed to moisture?

While the angular connector provides an IP65 rating when properly seated and tightened, ensure that the rubber gasket is intact and that the screw is fully secured. If moisture ingress is suspected, inspect the terminal contacts for corrosion immediately.

Installation and Operational Guidelines

  • Mechanical Seating: When installing the transmitter, ensure that the process connection is free of debris. Use a suitable wrench on the designated flats of the transmitter body to tighten. Avoid using the electrical connector housing as a leverage point, as this can damage the internal components or the connector seal.

  • Electrical Termination: Follow the EN 175301-803-A standard for wiring. Ensure that the cable gland is tightened sufficiently to prevent cable strain and to maintain the IP65 ingress protection rating. Use shielded cabling if the transmitter is installed in areas with significant electromagnetic interference from motors or frequency drives.

  • Thermal Management: While the transmitter is rated for temperatures up to 85 deg C, avoid mounting it in direct contact with excessively hot surfaces (e.g., uninsulated steam piping) that could cause the ambient temperature to exceed its rated limits, as this may cause premature electronic drift or failure.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...