Danfoss

Danfoss 060G2113 Pressure Transmitter AKS 33 Series

SKU 060G2113

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss
  • Product No.: 060G2113
  • Origin United States
  • Product Type: Pressure Transmitter | AKS 33
  • Payment: T/T, Western Union
  • Weight: 0.157 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The Danfoss 060G2113 (060G2113) is a precision-engineered pressure transmitter specifically developed for the refrigeration and air conditioning industries. As a key component of the AKS 33 series, this transmitter delivers reliable, high-accuracy pressure monitoring in challenging thermal environments. By providing a stable 4-20 mA output signal, the AKS 33 (060G2113) ensures seamless integration with electronic controllers, directly contributing to optimized system energy efficiency and the prevention of catastrophic compressor failures in cooling infrastructure.

Technical Configuration

This transmitter features a ruggedized design capable of maintaining performance across an extreme ambient and media temperature range, spanning from -40 deg C to 85 deg C. The device utilizes a sealed gauge reference, which prevents atmospheric moisture from affecting internal readings, ensuring long-term measurement consistency. The electrical interface employs an industry-standard angular connector (EN 175301-803-A), facilitating secure, IP65-rated connections that are resistant to the vibrations common in refrigeration skids and large-scale HVAC units. Its compact form factor and lightweight construction allow for flexible mounting in dense piping assemblies.

Technical Specifications

Feature Specification
Model 060G2113
Brand Danfoss
Series AKS 33
Net Weight 0.157 kg
Output Signal 4 to 20 mA
Pressure Reference Sealed gauge
Overload Pressure 33 bar (479 psi)
Enclosure Rating IP 65
Electrical Conn. Angular (EN 175301-803-A)
Ambient Temperature -40 to 85 deg C
Media Temperature -40 to 85 deg C

FAQs

Is this transmitter suitable for ammonia-based refrigeration systems?

The AKS 33 series is designed to be compatible with most common refrigerants, including fluorinated ones. For ammonia (R717) applications, please confirm the wetted parts compatibility in the official documentation, as specific versions may be required for chemical resistance.

What does the sealed gauge pressure reference signify?

Unlike a vented gauge reference, the sealed gauge is factory-calibrated to a reference pressure inside the sensor. This eliminates the risk of condensation or corrosive gases entering the sensor through a vent tube, making it ideal for high-humidity environments.

Can the transmitter be mounted in any orientation?

Yes, the AKS 33 can be mounted in any orientation. However, it is recommended to avoid mounting it where oil or sediment can collect at the pressure port, as this may lead to signal drift over time.

How do I troubleshoot an erratic output signal?

Erratic signals are often caused by poor grounding or EMI interference. Verify that the angular connector is firmly seated and that the cable shield is grounded at the controller side only, avoiding ground loops that often occur in distributed control systems.

Installation Guidelines and Best Practices

  • Vibration Management: While designed for HVAC equipment, excessive localized vibration can cause accelerated wear on the internal sensor diaphragm. Where possible, mount the transmitter on a rigid support or use a pressure-rated capillary loop to decouple it from high-frequency compressor vibration.
  • Connector Integrity: The IP65 rating is dependent on the proper seating of the gasket in the angular connector. When tightening the central screw, ensure it is secure but do not over-torque, as this can crack the connector housing or deform the sealing gasket.
  • Thermal Protection: Although the transmitter is rated for 85 deg C, avoid mounting the device directly on hot discharge lines. If the media temperature approaches the upper limit, use a standoff or a pressure-rated flexible tube to dissipate heat and protect the electronics from long-term thermal fatigue.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

060G2113

Stock & lead time on request

Call
1 su 1

Danfoss 060G2113 Pressure Transmitter AKS 33 Series

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 060G2113

  • Country of origin:United States

  • Product Type: Pressure Transmitter | AKS 33

  • Payment: T/T, Western Union

  • Weight: 157g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The Danfoss 060G2113 (060G2113) is a precision-engineered pressure transmitter specifically developed for the refrigeration and air conditioning industries. As a key component of the AKS 33 series, this transmitter delivers reliable, high-accuracy pressure monitoring in challenging thermal environments. By providing a stable 4-20 mA output signal, the AKS 33 (060G2113) ensures seamless integration with electronic controllers, directly contributing to optimized system energy efficiency and the prevention of catastrophic compressor failures in cooling infrastructure.

Technical Configuration

This transmitter features a ruggedized design capable of maintaining performance across an extreme ambient and media temperature range, spanning from -40 deg C to 85 deg C. The device utilizes a sealed gauge reference, which prevents atmospheric moisture from affecting internal readings, ensuring long-term measurement consistency. The electrical interface employs an industry-standard angular connector (EN 175301-803-A), facilitating secure, IP65-rated connections that are resistant to the vibrations common in refrigeration skids and large-scale HVAC units. Its compact form factor and lightweight construction allow for flexible mounting in dense piping assemblies.

Technical Specifications

Feature Specification
Model 060G2113
Brand Danfoss
Series AKS 33
Net Weight 0.157 kg
Output Signal 4 to 20 mA
Pressure Reference Sealed gauge
Overload Pressure 33 bar (479 psi)
Enclosure Rating IP 65
Electrical Conn. Angular (EN 175301-803-A)
Ambient Temperature -40 to 85 deg C
Media Temperature -40 to 85 deg C

FAQs

Is this transmitter suitable for ammonia-based refrigeration systems?

The AKS 33 series is designed to be compatible with most common refrigerants, including fluorinated ones. For ammonia (R717) applications, please confirm the wetted parts compatibility in the official documentation, as specific versions may be required for chemical resistance.

What does the sealed gauge pressure reference signify?

Unlike a vented gauge reference, the sealed gauge is factory-calibrated to a reference pressure inside the sensor. This eliminates the risk of condensation or corrosive gases entering the sensor through a vent tube, making it ideal for high-humidity environments.

Can the transmitter be mounted in any orientation?

Yes, the AKS 33 can be mounted in any orientation. However, it is recommended to avoid mounting it where oil or sediment can collect at the pressure port, as this may lead to signal drift over time.

How do I troubleshoot an erratic output signal?

Erratic signals are often caused by poor grounding or EMI interference. Verify that the angular connector is firmly seated and that the cable shield is grounded at the controller side only, avoiding ground loops that often occur in distributed control systems.

Installation Guidelines and Best Practices

  • Vibration Management: While designed for HVAC equipment, excessive localized vibration can cause accelerated wear on the internal sensor diaphragm. Where possible, mount the transmitter on a rigid support or use a pressure-rated capillary loop to decouple it from high-frequency compressor vibration.
  • Connector Integrity: The IP65 rating is dependent on the proper seating of the gasket in the angular connector. When tightening the central screw, ensure it is secure but do not over-torque, as this can crack the connector housing or deform the sealing gasket.
  • Thermal Protection: Although the transmitter is rated for 85 deg C, avoid mounting the device directly on hot discharge lines. If the media temperature approaches the upper limit, use a standoff or a pressure-rated flexible tube to dissipate heat and protect the electronics from long-term thermal fatigue.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...