Danfoss

Danfoss 060L312666 Thermostat KPS Series

SKU 060L312666

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss
  • Product No.: 060L312666
  • Origin United States
  • Product Type: KPS80 Thermostat M/8
  • Payment: T/T, Western Union
  • Weight: 2.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The Danfoss 060L312666 (KPS80) is a heavy-duty industrial thermostat engineered for critical process control in marine, power generation, and chemical processing environments. As a core component of the KPS series, this thermostat is designed to withstand harsh operating conditions, including high vibration and aggressive atmospheric contaminants. By providing accurate, repeatable temperature regulation, the KPS80 (060L312666) ensures system stability, preventing equipment overheating and minimizing unplanned downtime in mission-critical applications.

Technical Configuration

The KPS80 utilizes an adsorption charge type, providing reliable response times and high thermal stability. The unit features an SPDT gold-plated contact system, which ensures superior signal integrity even in low-voltage/low-current circuits, making it ideal for integration into modern DCS and PLC control loops. The hardware is housed in a rugged enclosure featuring a metal cable gland for secure electrical termination. The thermostat includes an adjustable differential, allowing engineers to fine-tune control loops between 4.5 K and 18 K to match specific process requirements and prevent rapid cycling of connected equipment.

Technical Specifications

Feature Specification
Model 060L312666
Series KPS 80
Charge Type Adsorption
Contact Function SPDT Gold
Differential 4.5 to 18 deg C (Adjustable)
Ambient Temperature -40 to 70 deg C
Electrical Conn. Screwed cable entry (DIN 40430)
Connection Size M 18 x 1.5
Max Contact Rating 10 A @ 440 VAC (AC1)
Weight 2 kg

FAQs

Why use gold-plated contacts in this thermostat?

Gold-plated contacts are essential for low-current applications (1–30 mA). They prevent the formation of insulating oxide layers on the contact surfaces, ensuring reliable switching signals for sensitive instrumentation and PLC digital inputs.

What is the purpose of the adjustable differential?

The adjustable differential allows you to define the temperature "deadband" between the switch-on and switch-off points. A wider differential (up to 18 K) is recommended for applications where frequent cycling would stress the equipment, such as large motor-driven cooling pumps.

Can this unit operate in high-temperature environments?

The thermostat is rated for continuous ambient operation up to 70 deg C. It can withstand up to 80 deg C for short-term periods (maximum 120 minutes), making it suitable for locations near heat-generating process machinery.

How does the adsorption charge type benefit the control loop?

Adsorption charging provides a very stable and predictable response to temperature changes, ensuring that the thermostat maintains its setpoint accuracy over long operational periods without the drift common in other sensing technologies.

Installation Guidelines and Best Practices

  • Mechanical Connection: The sensor uses an M 18 x 1.5 connection for pocket or hose integration. Ensure the sensor pocket is properly cleaned and thermally conductive paste is applied (if applicable) to maximize heat transfer efficiency between the media and the sensing element.
  • Electrical Termination: The metal cable gland provides robust protection. Ensure the cable is securely fastened to prevent stress on the internal terminal block. When wiring for gold-contact circuits, ensure the circuit impedance remains within the recommended 5-30 V range.
  • Calibration: After installation, perform an initial verification of the switching setpoint against a calibrated reference. Adjust the differential as required for your application and verify that the switch toggles cleanly at the designated temperature thresholds.
  • Environmental Protection: While the unit is designed for industrial use, ensure the cable entry is sealed effectively. Avoid mounting the thermostat directly in the path of high-pressure cleaning water to maintain long-term performance.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

060L312666

Stock & lead time on request

Call
1 su 1

Danfoss 060L312666 Thermostat KPS Series

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 060L312666

  • Country of origin:United States

  • Product Type: KPS80 Thermostat M/8

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The Danfoss 060L312666 (KPS80) is a heavy-duty industrial thermostat engineered for critical process control in marine, power generation, and chemical processing environments. As a core component of the KPS series, this thermostat is designed to withstand harsh operating conditions, including high vibration and aggressive atmospheric contaminants. By providing accurate, repeatable temperature regulation, the KPS80 (060L312666) ensures system stability, preventing equipment overheating and minimizing unplanned downtime in mission-critical applications.

Technical Configuration

The KPS80 utilizes an adsorption charge type, providing reliable response times and high thermal stability. The unit features an SPDT gold-plated contact system, which ensures superior signal integrity even in low-voltage/low-current circuits, making it ideal for integration into modern DCS and PLC control loops. The hardware is housed in a rugged enclosure featuring a metal cable gland for secure electrical termination. The thermostat includes an adjustable differential, allowing engineers to fine-tune control loops between 4.5 K and 18 K to match specific process requirements and prevent rapid cycling of connected equipment.

Technical Specifications

Feature Specification
Model 060L312666
Series KPS 80
Charge Type Adsorption
Contact Function SPDT Gold
Differential 4.5 to 18 deg C (Adjustable)
Ambient Temperature -40 to 70 deg C
Electrical Conn. Screwed cable entry (DIN 40430)
Connection Size M 18 x 1.5
Max Contact Rating 10 A @ 440 VAC (AC1)
Weight 2 kg

FAQs

Why use gold-plated contacts in this thermostat?

Gold-plated contacts are essential for low-current applications (1–30 mA). They prevent the formation of insulating oxide layers on the contact surfaces, ensuring reliable switching signals for sensitive instrumentation and PLC digital inputs.

What is the purpose of the adjustable differential?

The adjustable differential allows you to define the temperature "deadband" between the switch-on and switch-off points. A wider differential (up to 18 K) is recommended for applications where frequent cycling would stress the equipment, such as large motor-driven cooling pumps.

Can this unit operate in high-temperature environments?

The thermostat is rated for continuous ambient operation up to 70 deg C. It can withstand up to 80 deg C for short-term periods (maximum 120 minutes), making it suitable for locations near heat-generating process machinery.

How does the adsorption charge type benefit the control loop?

Adsorption charging provides a very stable and predictable response to temperature changes, ensuring that the thermostat maintains its setpoint accuracy over long operational periods without the drift common in other sensing technologies.

Installation Guidelines and Best Practices

  • Mechanical Connection: The sensor uses an M 18 x 1.5 connection for pocket or hose integration. Ensure the sensor pocket is properly cleaned and thermally conductive paste is applied (if applicable) to maximize heat transfer efficiency between the media and the sensing element.
  • Electrical Termination: The metal cable gland provides robust protection. Ensure the cable is securely fastened to prevent stress on the internal terminal block. When wiring for gold-contact circuits, ensure the circuit impedance remains within the recommended 5-30 V range.
  • Calibration: After installation, perform an initial verification of the switching setpoint against a calibrated reference. Adjust the differential as required for your application and verify that the switch toggles cleanly at the designated temperature thresholds.
  • Environmental Protection: While the unit is designed for industrial use, ensure the cable entry is sealed effectively. Avoid mounting the thermostat directly in the path of high-pressure cleaning water to maintain long-term performance.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...