Danfoss

Danfoss KPS79 060L310466 KPS Series Thermostat

SKU KPS79 060L310466

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss
  • Product No.: KPS79 060L310466
  • Origin United States
  • Product Type: Pressure switch and Thermostat KPS
  • Payment: T/T, Western Union
  • Weight: 3.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The Danfoss KPS79 060L310466 is a KPS series thermostat engineered for robust temperature control in demanding industrial applications. This KPS 79 unit utilizes a capillary tube sensing system to provide accurate switching within a defined setting range. Designed for high reliability, the device is suitable for monitoring and controlling temperature in fluid or gas systems where precise, adjustable differential control is required. The 060L310466 provides stable performance in harsh environments, ensuring effective thermal management for automated industrial processes.

Features

  • Adjustable temperature setting range of 50 to 100 Celsius.
  • Integrated adjustable mechanical differential (4 to 16 Celsius).
  • Durable capillary tube design with 2 m length.
  • High maximum sensor temperature tolerance up to 200 Celsius.
  • Suitable for use with various sensor pocket lengths for flexible installation.

Applications

  • Heating, ventilation, and air conditioning (HVAC) systems.
  • Industrial process temperature regulation.
  • Cooling water circuits.
  • Boilers and heat exchangers.
  • Compressor and pump protection.

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Model KPS79 060L310466
Series KPS
Setting Range 50 – 100 Celsius
Mechanical Differential 4 – 16 Celsius (Adjustable)
Max Sensor Temperature 200 Celsius
Capillary Tube Length 2 m
Compatible Sensor Pockets 65 mm, 75 mm, 110 mm, 160 mm
Shipping Weight 3 Kg

Installation Guidelines

  • Mounting: Ensure the thermostat enclosure is mounted in a stable location free from excessive vibration.
  • Sensor Placement: The sensor bulb must be fully immersed in the medium being monitored to ensure accurate temperature sensing. Use appropriate thermowells or pockets as specified.
  • Capillary Handling: Avoid sharp bends or kinks in the 2 m capillary tube, as this can damage the internal system and affect accuracy.
  • Calibration: After installation, verify the switching point within the 50 – 100 Celsius range and adjust the differential as required for the specific process load.
  • Environment: Protect the housing from direct exposure to corrosive substances or moisture ingress.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the adjustable temperature range for the KPS79?
The setting range for this unit is between 50 Celsius and 100 Celsius.
Can the mechanical differential be adjusted on this model?
Yes, the mechanical differential is adjustable between 4 Celsius and 16 Celsius to suit specific process requirements.
What is the maximum temperature the sensor can withstand?
The maximum sensor temperature for this device is 200 Celsius.
What is the length of the capillary tube included with this unit?
This unit is equipped with a 2 meter long capillary tube.
Reviews

KPS79 060L310466

Stock & lead time on request

Call
1 su 1

Danfoss KPS79 060L310466 KPS Series Thermostat

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: KPS79 060L310466

  • Country of origin:United States

  • Product Type: Pressure switch and Thermostat KPS

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Danfoss KPS79 060L310466 is a KPS series thermostat engineered for robust temperature control in demanding industrial applications. This KPS 79 unit utilizes a capillary tube sensing system to provide accurate switching within a defined setting range. Designed for high reliability, the device is suitable for monitoring and controlling temperature in fluid or gas systems where precise, adjustable differential control is required. The 060L310466 provides stable performance in harsh environments, ensuring effective thermal management for automated industrial processes.

Features

  • Adjustable temperature setting range of 50 to 100 Celsius.
  • Integrated adjustable mechanical differential (4 to 16 Celsius).
  • Durable capillary tube design with 2 m length.
  • High maximum sensor temperature tolerance up to 200 Celsius.
  • Suitable for use with various sensor pocket lengths for flexible installation.

Applications

  • Heating, ventilation, and air conditioning (HVAC) systems.
  • Industrial process temperature regulation.
  • Cooling water circuits.
  • Boilers and heat exchangers.
  • Compressor and pump protection.

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Model KPS79 060L310466
Series KPS
Setting Range 50 – 100 Celsius
Mechanical Differential 4 – 16 Celsius (Adjustable)
Max Sensor Temperature 200 Celsius
Capillary Tube Length 2 m
Compatible Sensor Pockets 65 mm, 75 mm, 110 mm, 160 mm
Shipping Weight 3 Kg

Installation Guidelines

  • Mounting: Ensure the thermostat enclosure is mounted in a stable location free from excessive vibration.
  • Sensor Placement: The sensor bulb must be fully immersed in the medium being monitored to ensure accurate temperature sensing. Use appropriate thermowells or pockets as specified.
  • Capillary Handling: Avoid sharp bends or kinks in the 2 m capillary tube, as this can damage the internal system and affect accuracy.
  • Calibration: After installation, verify the switching point within the 50 – 100 Celsius range and adjust the differential as required for the specific process load.
  • Environment: Protect the housing from direct exposure to corrosive substances or moisture ingress.

What is the adjustable temperature range for the KPS79?

The setting range for this unit is between 50 Celsius and 100 Celsius.

Can the mechanical differential be adjusted on this model?

Yes, the mechanical differential is adjustable between 4 Celsius and 16 Celsius to suit specific process requirements.

What is the maximum temperature the sensor can withstand?

The maximum sensor temperature for this device is 200 Celsius.

What is the length of the capillary tube included with this unit?

This unit is equipped with a 2 meter long capillary tube.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...