Engineered for high-integrity communication within proprietary Local Control Network (LCN) architectures, the Honeywell 51308111-002 serves as a dedicated dual-channel coaxial link. This cable set is critical for interconnecting essential node components and processor cards in Honeywell TDC 3000 and TPS systems, ensuring predictable signal propagation and low-attenuation performance.

The 51308111-002 assembly relies on industrial-grade RG-59 coaxial cables, which provide stable characteristic impedance and effective shielding against high-frequency disturbances. To further reinforce signal reliability in noisy industrial environments, each cable is equipped with pre-installed ferrite cores that suppress common-mode electromagnetic interference (EMI) and radio frequency interference (RFI). Distinct physical marking, designated as "CABLE" and "CORD B" (Mark 1), allows commissioning and maintenance engineers to quickly map and verify dual-channel connection layouts during installation.

Features

  • Constructed from premium RG-59 coaxial cable for stable impedance control and low transmission losses.
  • Integrated inline ferrite suppressors on both segments protect critical data channels from high-frequency electrical noise.
  • Explicitly marked with physical labels "CABLE" and "CORD B" (Mark 1) to ensure error-free diagnostic tracing and port alignment.
  • Pre-terminated with robust coaxial connectors designed for direct mating with legacy and modern LCN modules.
  • Durable outer sheathing formulated to resist typical industrial environmental degradation, abrasion, and thermal stress in control room cabinets.

Applications

  • Interconnection of system nodes in Honeywell TDC 3000 and TPS (TotalPlant Solution) automation environments.
  • Point-to-point high-frequency data transmission within Local Control Network cabinet structures.
  • Refinery, chemical, and power generation control rooms where robust coaxial noise immunity is required.

Technical Specifications

Manufacturer Honeywell
Part Number 51308111-002
Cable Type Dual Coaxial Assembly (RG-59)
Length 2.0 meters
Interference Protection Integrated inline ferrite cores
Marking Labels "CABLE" and "CORD B" (Mark 1)
System Integration Honeywell LCN (Local Control Network)
Shipping Weight 2.0 kg

Installation Guidelines

  • Maintain appropriate separation between the coaxial signal cable path and high-current AC power cables to prevent induced noise.
  • Do not exceed the minimum allowable bend radius for RG-59 coaxial cables to avoid mechanical deformation of the dielectric layer.
  • Ensure the pre-installed ferrite sleeves remain clean and physically undamaged during routing.
  • Verify that the "CABLE" and "CORD B" terminations align correctly with the corresponding ports on the LCN network interface boards.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell 51308111-002 cable set?
The Honeywell 51308111-002 is a 2-meter dual coaxial cable assembly used to establish secure, low-attenuation signal connections between nodes within a Honeywell Local Control Network (LCN).
Why does this coaxial cable set feature integrated ferrites?
The inline ferrite cores act as electromagnetic suppressors, minimizing high-frequency EMI and RFI noise to ensure stable, error-free communication across the control network.
What do the markings 'CABLE' and 'CORD B' indicate?
These physical labels (Mark 1) are applied to the cable channels to help technical personnel correctly align, map, and trace dual-channel redundancy paths during installation and troubleshooting.
Reviews

51308111-002

Stock & lead time on request

Call
1 su 1

Honeywell 51308111-002 LCN Coaxial Cable Set

Only 5 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 51308111-002

  • Country of origin:United States

  • Product Type: Coaxial Cable Assemblies

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Engineered for high-integrity communication within proprietary Local Control Network (LCN) architectures, the Honeywell 51308111-002 serves as a dedicated dual-channel coaxial link. This cable set is critical for interconnecting essential node components and processor cards in Honeywell TDC 3000 and TPS systems, ensuring predictable signal propagation and low-attenuation performance.

The 51308111-002 assembly relies on industrial-grade RG-59 coaxial cables, which provide stable characteristic impedance and effective shielding against high-frequency disturbances. To further reinforce signal reliability in noisy industrial environments, each cable is equipped with pre-installed ferrite cores that suppress common-mode electromagnetic interference (EMI) and radio frequency interference (RFI). Distinct physical marking, designated as "CABLE" and "CORD B" (Mark 1), allows commissioning and maintenance engineers to quickly map and verify dual-channel connection layouts during installation.

Features

  • Constructed from premium RG-59 coaxial cable for stable impedance control and low transmission losses.
  • Integrated inline ferrite suppressors on both segments protect critical data channels from high-frequency electrical noise.
  • Explicitly marked with physical labels "CABLE" and "CORD B" (Mark 1) to ensure error-free diagnostic tracing and port alignment.
  • Pre-terminated with robust coaxial connectors designed for direct mating with legacy and modern LCN modules.
  • Durable outer sheathing formulated to resist typical industrial environmental degradation, abrasion, and thermal stress in control room cabinets.

Applications

  • Interconnection of system nodes in Honeywell TDC 3000 and TPS (TotalPlant Solution) automation environments.
  • Point-to-point high-frequency data transmission within Local Control Network cabinet structures.
  • Refinery, chemical, and power generation control rooms where robust coaxial noise immunity is required.

Technical Specifications

Manufacturer Honeywell
Part Number 51308111-002
Cable Type Dual Coaxial Assembly (RG-59)
Length 2.0 meters
Interference Protection Integrated inline ferrite cores
Marking Labels "CABLE" and "CORD B" (Mark 1)
System Integration Honeywell LCN (Local Control Network)
Shipping Weight 2.0 kg

Installation Guidelines

  • Maintain appropriate separation between the coaxial signal cable path and high-current AC power cables to prevent induced noise.
  • Do not exceed the minimum allowable bend radius for RG-59 coaxial cables to avoid mechanical deformation of the dielectric layer.
  • Ensure the pre-installed ferrite sleeves remain clean and physically undamaged during routing.
  • Verify that the "CABLE" and "CORD B" terminations align correctly with the corresponding ports on the LCN network interface boards.

What is the primary function of the Honeywell 51308111-002 cable set?

The Honeywell 51308111-002 is a 2-meter dual coaxial cable assembly used to establish secure, low-attenuation signal connections between nodes within a Honeywell Local Control Network (LCN).

Why does this coaxial cable set feature integrated ferrites?

The inline ferrite cores act as electromagnetic suppressors, minimizing high-frequency EMI and RFI noise to ensure stable, error-free communication across the control network.

What do the markings 'CABLE' and 'CORD B' indicate?

These physical labels (Mark 1) are applied to the cable channels to help technical personnel correctly align, map, and trace dual-channel redundancy paths during installation and troubleshooting.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.