The Honeywell CC-TPIX11 is a 12-inch redundant Input Output Termination Assembly (IOTA) engineered for the Experion Process Knowledge System (PKS) Series C architecture. Operating as the physical termination foundation for high-speed counter signals, the CC-TPIX11 directly mates with the Honeywell CC-PPIX01 Pulse Input Module with Fast Cut-off. It facilitates 8-channel pulse counting, frequency measurement, and high-speed signal processing across continuous and batch processing environments.

Designed for mission-critical applications demanding fault-tolerant continuous operation, the CC-TPIX11 redundant IOTA architecture allows two CC-PPIX01 pulse input modules to be mounted side-by-side on a single termination assembly. This dual-module mounting arrangement enables seamless parallel processing and automatic hardware failover on the pulse input channels without disturbing field wiring or backplane signal routing.

The Honeywell CC-TPIX11 provides organized field wiring termination terminals for turbine flowmeters, positive displacement meters, optical encoders, and frequency-based transmitters. By establishing clean signal paths and reliable connection points, the assembly ensures low noise sensitivity and precise signal conditioning, allowing the underlying CC-PPIX01 modules to execute fast cut-off interlocks and high-accuracy totalization routines.

Features

  • Designed specifically as a 12-inch redundant IOTA for Honeywell Experion Series C I/O subsystems.
  • Interfaces directly with the CC-PPIX01 Pulse Input Module with Fast Cut-off.
  • Supports full hardware redundancy across 8 pulse input channels.
  • Dual-slot IOTA base accommodates primary and backup I/O modules on a single assembly.
  • Facilitates high-speed frequency measurement, totalization, and fast cut-off processing.
  • Simplifies panel layout by combining field terminal blocks and dual-module backplane routing in a compact footprint.

Applications

  • Custody Transfer & Flow Measurement: Interfaces with pulse-output flowmeters (turbine, positive displacement, vortex) for high-accuracy liquid and gas totalization.
  • High-Speed Batching & Fast Cut-off: Connects to pulse transmitters in automated filling lines where immediate valve closure is triggered by exact pulse count thresholds.
  • Rotating Equipment Speed Monitoring: Transmits frequency signals from proximity pick-ups and tachometers on turbines, pumps, and compressors to control processors.
  • Blending Systems: Connects multi-stream pulse metering systems to Series C controllers for precise ratio control and additive dosing.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model Number CC-TPIX11
Product Type Input Output Termination Assembly (IOTA)
Architecture Experion Series C
Associated I/O Module CC-PPIX01 (Pulse Input w/ Fast Cut-off)
Redundancy Redundant
Number of Channels 8 Channels
Assembly Physical Size 12 inches (304 mm)

Installation Guidelines

  1. Inspect the Honeywell CC-TPIX11 assembly for intact connector pins and mounting hardware prior to installation.
  2. Mount the 12-inch IOTA onto the standard Experion Series C cabinet vertical channel or mounting plate.
  3. Ensure cabinet power to the target I/O carrier section is isolated before attaching or wiring the assembly.
  4. Route field pulse signal cables through cabinet wire ducts, separating low-level frequency lines from high-voltage AC or inductive load cables.
  5. Connect field wiring to the designated screw terminals, ensuring proper shield grounding at the designated system ground point to prevent noise induction.
  6. Align the primary and secondary CC-PPIX01 Pulse Input modules with the dual IOTA board connectors and press firmly until seated and latched.

Replacement & Commissioning

  • Redundant Module Replacement: In an active redundant pairing, a faulty CC-PPIX01 module can be extracted and replaced on the CC-TPIX11 base without interrupting pulse counting on the active partner module.
  • Wiring Verification: Confirm that pulse signal amplitudes and sensor power loop connections meet the input threshold requirements of the CC-PPIX01 before powering up the channel.
  • Control Builder Assignment: Verify that the CC-TPIX11 redundant IOTA block is properly configured in Experion Control Builder under the corresponding C300 controller I/O link tree.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the function of the Honeywell CC-TPIX11 IOTA?
The Honeywell CC-TPIX11 is a 12-inch redundant Input Output Termination Assembly (IOTA) designed for Experion Series C systems to terminate field pulse signals and host CC-PPIX01 Pulse Input modules.
Which I/O module is compatible with the Honeywell CC-TPIX11?
The Honeywell CC-TPIX11 is specifically designed to interface with the Honeywell CC-PPIX01 Pulse Input Module with Fast Cut-off.
How many channels does the Honeywell CC-TPIX11 assembly support?
The Honeywell CC-TPIX11 assembly supports 8 pulse input channels in a fully redundant module configuration.
Does the Honeywell CC-TPIX11 support hot-swapping of I/O modules?
Yes, because the Honeywell CC-TPIX11 is a redundant IOTA, individual CC-PPIX01 modules can be removed or replaced without interrupting pulse scanning or totalization on the active secondary module.
Reviews

CC-TPIX11

Stock & lead time on request

Call
1 su 4

Honeywell CC-TPIX11 Experion Series C Redundant Pulse Input IOTA

Only 2 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-TPIX11

  • Country of origin:United States

  • Product Type: Pulse Input Termination Assemblies

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 850g

  • Dimensions: 304 x 125 x 60 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Honeywell CC-TPIX11 is a 12-inch redundant Input Output Termination Assembly (IOTA) engineered for the Experion Process Knowledge System (PKS) Series C architecture. Operating as the physical termination foundation for high-speed counter signals, the CC-TPIX11 directly mates with the Honeywell CC-PPIX01 Pulse Input Module with Fast Cut-off. It facilitates 8-channel pulse counting, frequency measurement, and high-speed signal processing across continuous and batch processing environments.

Designed for mission-critical applications demanding fault-tolerant continuous operation, the CC-TPIX11 redundant IOTA architecture allows two CC-PPIX01 pulse input modules to be mounted side-by-side on a single termination assembly. This dual-module mounting arrangement enables seamless parallel processing and automatic hardware failover on the pulse input channels without disturbing field wiring or backplane signal routing.

The Honeywell CC-TPIX11 provides organized field wiring termination terminals for turbine flowmeters, positive displacement meters, optical encoders, and frequency-based transmitters. By establishing clean signal paths and reliable connection points, the assembly ensures low noise sensitivity and precise signal conditioning, allowing the underlying CC-PPIX01 modules to execute fast cut-off interlocks and high-accuracy totalization routines.

Features

  • Designed specifically as a 12-inch redundant IOTA for Honeywell Experion Series C I/O subsystems.
  • Interfaces directly with the CC-PPIX01 Pulse Input Module with Fast Cut-off.
  • Supports full hardware redundancy across 8 pulse input channels.
  • Dual-slot IOTA base accommodates primary and backup I/O modules on a single assembly.
  • Facilitates high-speed frequency measurement, totalization, and fast cut-off processing.
  • Simplifies panel layout by combining field terminal blocks and dual-module backplane routing in a compact footprint.

Applications

  • Custody Transfer & Flow Measurement: Interfaces with pulse-output flowmeters (turbine, positive displacement, vortex) for high-accuracy liquid and gas totalization.
  • High-Speed Batching & Fast Cut-off: Connects to pulse transmitters in automated filling lines where immediate valve closure is triggered by exact pulse count thresholds.
  • Rotating Equipment Speed Monitoring: Transmits frequency signals from proximity pick-ups and tachometers on turbines, pumps, and compressors to control processors.
  • Blending Systems: Connects multi-stream pulse metering systems to Series C controllers for precise ratio control and additive dosing.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model Number CC-TPIX11
Product Type Input Output Termination Assembly (IOTA)
Architecture Experion Series C
Associated I/O Module CC-PPIX01 (Pulse Input w/ Fast Cut-off)
Redundancy Redundant
Number of Channels 8 Channels
Assembly Physical Size 12 inches (304 mm)

Installation Guidelines

  1. Inspect the Honeywell CC-TPIX11 assembly for intact connector pins and mounting hardware prior to installation.
  2. Mount the 12-inch IOTA onto the standard Experion Series C cabinet vertical channel or mounting plate.
  3. Ensure cabinet power to the target I/O carrier section is isolated before attaching or wiring the assembly.
  4. Route field pulse signal cables through cabinet wire ducts, separating low-level frequency lines from high-voltage AC or inductive load cables.
  5. Connect field wiring to the designated screw terminals, ensuring proper shield grounding at the designated system ground point to prevent noise induction.
  6. Align the primary and secondary CC-PPIX01 Pulse Input modules with the dual IOTA board connectors and press firmly until seated and latched.

Replacement & Commissioning

  • Redundant Module Replacement: In an active redundant pairing, a faulty CC-PPIX01 module can be extracted and replaced on the CC-TPIX11 base without interrupting pulse counting on the active partner module.
  • Wiring Verification: Confirm that pulse signal amplitudes and sensor power loop connections meet the input threshold requirements of the CC-PPIX01 before powering up the channel.
  • Control Builder Assignment: Verify that the CC-TPIX11 redundant IOTA block is properly configured in Experion Control Builder under the corresponding C300 controller I/O link tree.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-TPIX11 Experion Series C Redundant Pulse Input IOTA

What is the function of the Honeywell CC-TPIX11 IOTA?

The Honeywell CC-TPIX11 is a 12-inch redundant Input Output Termination Assembly (IOTA) designed for Experion Series C systems to terminate field pulse signals and host CC-PPIX01 Pulse Input modules.

Which I/O module is compatible with the Honeywell CC-TPIX11?

The Honeywell CC-TPIX11 is specifically designed to interface with the Honeywell CC-PPIX01 Pulse Input Module with Fast Cut-off.

How many channels does the Honeywell CC-TPIX11 assembly support?

The Honeywell CC-TPIX11 assembly supports 8 pulse input channels in a fully redundant module configuration.

Does the Honeywell CC-TPIX11 support hot-swapping of I/O modules?

Yes, because the Honeywell CC-TPIX11 is a redundant IOTA, individual CC-PPIX01 modules can be removed or replaced without interrupting pulse scanning or totalization on the active secondary module.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.