Honeywell

Honeywell FC-USI-0001 V1.0 Universal Safety Interface

SKU FC-USI-0001 V1.0

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: FC-USI-0001 V1.0

  • Product Type: Universal Safety Interface

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 720g

  • Dimensions: 17.6 cm × 3.52 cm × 21.2 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product overview

The Honeywell FC-USI-0001 V1.0 is a Universal Safety Interface for Safety Manager systems. It provides the communication interface between the safety controller environment and supported external communication paths. Because this is safety-system hardware, hardware revision, Safety Manager release and approved replacement procedure are part of the identity check.

Technical specifications

Manufacturer Honeywell
Model FC-USI-0001
Version on this listing V1.0
Product type Universal Safety Interface
System family Honeywell Safety Manager
Product dimensions 176 × 35.2 × 212 mm (H × W × D)
Net weight 0.7 kg
Documented migration boundary FX-USI-0002 replacement support requires Safety Manager R140 or later

Compatibility and replacement boundary

Honeywell documents FX-USI-0002 as a replacement for FC-USI-0001 only for Safety Manager R140 and later. Earlier releases require a separate compatibility plan. Verify software release, hardware revision, communication configuration and approved safety validation before replacement.

Dimensions and shipping

Estimated package: 25 × 24 × 11 cm; estimated shipping weight 1.3 kg. Warehouse measurement takes precedence.

FAQ

What does FC-USI-0001 do?

It is the Universal Safety Interface used to connect Honeywell Safety Manager hardware to supported communication paths.

Can FX-USI-0002 always replace it?

No. Honeywell states that FX-USI-0002 replacement support applies from Safety Manager R140 and higher.

What are the documented dimensions?

Honeywell specifies 176 × 35.2 × 212 mm and a weight of 0.7 kg.

Should a safety-system replacement be made by model number alone?

No. Confirm the Safety Manager release, hardware revision, configuration backup and approved validation procedure.

Is the shipping package measured?

No. It is an estimate for freight planning and must be confirmed before dispatch.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FC-USI-0001 V1.0 Universal Safety Interface

Quantità
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 su 3
Only 4 item(s) left in stock
Quantità
Visualizza dettagli completi
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

No detailed specifications found for this SKU.

Technical knowledge

1746-A7 Verifiche di sostituzione del telaio: slot, alimentazione e interconnessioni

Una lista di controllo tecnica per sostituire un Allen-Bradley 1746-A7: verificare la serie del telaio, il carico del backplane, la disposizione degli slot, i cavi di interconnessione, il montaggio,...

Controlli per la sostituzione di IC200MDL650: polarità logica, filtri e comuni

Una guida alla sostituzione sul campo del GE Fanuc IC200MDL650, che tratta la logica negativa in base alla revisione, quattro gruppi comuni, le soglie a 24 VDC, il filtraggio degli ingressi, i...

Controlli per la sostituzione di IC697CPX935: memoria, porte e alimentazione del rack

Una guida alla sostituzione dell’IC697CPX935 incentrata sulle esigenze sul campo, che illustra la memoria veloce, il comportamento seriale dipendente dal firmware, l’alimentazione del rack, il...

Controlli per la sostituzione dell’IC693DSM324: FSSB, firmware e controllo follower

Una guida alla sostituzione dell'IC693DSM324 sul campo, con controlli dell'unità host Series 90-30, registri della catena servo FSSB, budget di alimentazione a 5 V, limiti del firmware, controllo...

Verifiche di sostituzione HIMA F3430: valori nominali dei contatti e limiti di sicurezza

Una guida alla sostituzione di HIMA F3430, pensata per il lavoro sul campo, che tratta la portata dei contatti del relè, il declassamento per carichi CC, i fusibili, le differenze tra F3330 e F3331,...

Verifiche per la sostituzione di IC697PWR710: budget di carico e limiti dei rack doppi

Una guida pratica alla sostituzione dell’IC697PWR710, con calcoli del carico a 5 V, limiti dei rack doppi, cavi di estensione, controlli degli ingressi, comportamento delle protezioni e rischi legati...