Honeywell

Honeywell FS-CPCHAS-0002 V1.1 Safety Manager Redundant Controller Chassis

SKU FS-CPCHAS-0002 V1.1

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: FS-CPCHAS-0002 V1.1
  • Origin United States
  • Product Type: Safety Controller Chassis
  • Payment: T/T, Western Union
  • Weight: 4.5 kg
  • Dimensions: 483 x 177 x 280 mm (W x H x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FS-CPCHAS-0002 V1.1 Safety Manager Redundant Controller Chassis

Quantità

Product Description

Honeywell FS-CPCHAS-0002 V1.1 is a redundant Control Processor chassis designed for the Safety Manager system. It provides the physical rack frame and backplane interconnection structure required to house and operate a redundant safety controller configuration. The FS-CPCHAS-0002 V1.1 chassis enables high-integrity process safety management in industrial automation, serving as the central hardware framework for logic solver operations in Safety Instrumented Systems (SIS).

Features

  • Built specifically for housing redundant Safety Manager Control Processor modules.
  • Provides backplane power, communication, and control signal routing for Quad Processor Packs and associated controller components.
  • Integrated rack mounting design intended for installation within standard swing frames or cabinets.
  • Engineered to support fault-tolerant hardware architectures up to Safety Integrity Level 3 (SIL 3).

Applications

  • Safety Instrumented Systems (SIS)
  • Emergency Shutdown (ESD) systems
  • Fire and Gas (F&G) detection and control systems
  • Process safety logic solvers in oil & gas, chemical, and power generation facilities

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model FS-CPCHAS-0002 V1.1
Product Type Redundant Controller Chassis
System Compatibility Safety Manager A.R.T.
Operating Temperature -5 degC to +70 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 5% to 95% (non-condensing)
Vibration (Sinusoidal) 10 to 57 Hz: 0.075 mm amplitude; 57 to 150 Hz: 1 G
Shock 15 G (11 ms duration, 3 axes)

Installation Guidelines

  • Mount the chassis inside a standard enclosure or swing frame in an upright orientation to ensure adequate ventilation.
  • Maintain unobstructed airflow around the chassis to prevent thermal buildup within the enclosure.
  • Connect the chassis frame securely to the safety ground bar using approved grounding straps.
  • Follow proper Electrostatic Discharge (ESD) precautions when inserting or removing modules from the chassis backplane.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the chassis?
The chassis serves as the physical mounting frame and backplane connection interface for redundant Control Processor modules in a Safety Manager system.
What is the operating temperature range for the device?
The operating temperature range measured at the Control Processor modules is from -5 degC to +70 degC.
Does the unit support high-integrity safety applications?
Yes, when fully configured within a Safety Manager architecture, it supports safety instrumented functions up to SIL 3.
Reviews

FS-CPCHAS-0002 V1.1

Stock & lead time on request

Call
1 su 3

Honeywell FS-CPCHAS-0002 V1.1 Safety Manager Redundant Controller Chassis

Only 2 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: FS-CPCHAS-0002 V1.1

  • Country of origin:United States

  • Product Type: Safety Controller Chassis

  • Payment: T/T, Western Union

  • Weight: 4500g

  • Dimensions: 483 x 177 x 280 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Honeywell FS-CPCHAS-0002 V1.1 is a redundant Control Processor chassis designed for the Safety Manager system. It provides the physical rack frame and backplane interconnection structure required to house and operate a redundant safety controller configuration. The FS-CPCHAS-0002 V1.1 chassis enables high-integrity process safety management in industrial automation, serving as the central hardware framework for logic solver operations in Safety Instrumented Systems (SIS).

Features

  • Built specifically for housing redundant Safety Manager Control Processor modules.
  • Provides backplane power, communication, and control signal routing for Quad Processor Packs and associated controller components.
  • Integrated rack mounting design intended for installation within standard swing frames or cabinets.
  • Engineered to support fault-tolerant hardware architectures up to Safety Integrity Level 3 (SIL 3).

Applications

  • Safety Instrumented Systems (SIS)
  • Emergency Shutdown (ESD) systems
  • Fire and Gas (F&G) detection and control systems
  • Process safety logic solvers in oil & gas, chemical, and power generation facilities

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model FS-CPCHAS-0002 V1.1
Product Type Redundant Controller Chassis
System Compatibility Safety Manager A.R.T.
Operating Temperature -5 degC to +70 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 5% to 95% (non-condensing)
Vibration (Sinusoidal) 10 to 57 Hz: 0.075 mm amplitude; 57 to 150 Hz: 1 G
Shock 15 G (11 ms duration, 3 axes)

Installation Guidelines

  • Mount the chassis inside a standard enclosure or swing frame in an upright orientation to ensure adequate ventilation.
  • Maintain unobstructed airflow around the chassis to prevent thermal buildup within the enclosure.
  • Connect the chassis frame securely to the safety ground bar using approved grounding straps.
  • Follow proper Electrostatic Discharge (ESD) precautions when inserting or removing modules from the chassis backplane.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FS-CPCHAS-0002 V1.1 Safety Manager Redundant Controller Chassis

What is the primary function of the chassis?

The chassis serves as the physical mounting frame and backplane connection interface for redundant Control Processor modules in a Safety Manager system.

What is the operating temperature range for the device?

The operating temperature range measured at the Control Processor modules is from -5 degC to +70 degC.

Does the unit support high-integrity safety applications?

Yes, when fully configured within a Safety Manager architecture, it supports safety instrumented functions up to SIL 3.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.