The Honeywell TC-FXX172 is a 17-slot uncoated rack chassis engineered to serve as a reliable structural and electrical backbone for Experion PKS control system architectures. This chassis provides physical housing, backplane communication routing, and power distribution for I/O modules, controllers, and associated system hardware. It ensures secure mechanical retention and organized signal distribution in demanding industrial automation environments.

Designed for integration within distributed control systems, the TC-FXX172 supports scalable system configurations, allowing engineers to build modular and easily expandable control nodes. The uncoated backplane design facilitates efficient heat dissipation while maintaining robust electrical continuity across all active slots. It connects directly to system power supplies and communication links to maintain high availability and continuous data exchange throughout the plant network.

Features

  • 17 physical slots supporting high-density module placement
  • Uncoated backplane architecture optimized for controlled industrial environments
  • Integrated backplane bus for high-speed data communication between modules
  • Robust mechanical construction designed to withstand standard industrial vibration and shock
  • Direct compatibility with Honeywell Experion PKS hardware components
  • Standardized mounting profile for streamlined cabinet installation

Applications

  • Distributed Control Systems (DCS)
  • Oil and gas processing facilities
  • Chemical and petrochemical plants
  • Power generation and distribution
  • Continuous and batch manufacturing processes

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Product Model TC-FXX172
Product Type Slot Rack Chassis
Series Experion PKS
Number of Slots 17 Slots
Chassis Type Uncoated Rack Chassis
Mounting Type Standard DIN rail or panel mount (cabinet installation)
Dimensions 17.1 cm x 40.0 cm x 14.6 cm
Net Weight 1.4 kg
Country of Origin USA

Installation Guidelines

  1. Verify that the part number TC-FXX172 matches system engineering documentation prior to physical placement.
  2. De-energize all power distribution units and associated cabinet feeds before handling the chassis.
  3. Inspect the chassis and backplane pins for any shipping damage or contamination.
  4. Securely mount the chassis to the designated panel or rack using appropriate hardware, ensuring proper grounding.
  5. Install compatible Experion PKS modules into the desired slots, taking care not to bend backplane pins.
  6. Connect power supply modules and communication cables according to system architecture drawings.
  7. Apply power and verify module status indicators during system commissioning.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What system architecture is the Honeywell TC-FXX172 designed for?
The Honeywell TC-FXX172 is specifically designed for use within Honeywell Experion PKS distributed control systems, providing the physical housing and backplane for controllers and I/O modules.
How many modules can be installed in the TC-FXX172 chassis?
The Honeywell TC-FXX172 features a 17-slot configuration, allowing up to 17 compatible system modules to be mounted and interconnected on a single backplane.
What does the uncoated designation mean for the TC-FXX172?
The uncoated designation of the Honeywell TC-FXX172 indicates that the backplane traces lack a conformal coating, making it best suited for controlled industrial environments where corrosive gases and extreme humidity are absent.
What are the physical dimensions and weight of the TC-FXX172 chassis?
The Honeywell TC-FXX172 measures 17.1 cm x 40.0 cm x 14.6 cm and has a net weight of approximately 1.4 kg.
Reviews

TC-FXX172

Stock & lead time on request

Call
1 su 3

Telaio rack non rivestito a 17 slot Honeywell TC-FXX172

Only 6 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TC-FXX172

  • Country of origin:United States

  • Product Type: Chassis rack per slot

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1400g

  • Dimensions: 17.1 cm x 40.0 cm x 14.6 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Honeywell TC-FXX172 is a 17-slot uncoated rack chassis engineered to serve as a reliable structural and electrical backbone for Experion PKS control system architectures. This chassis provides physical housing, backplane communication routing, and power distribution for I/O modules, controllers, and associated system hardware. It ensures secure mechanical retention and organized signal distribution in demanding industrial automation environments.

Designed for integration within distributed control systems, the TC-FXX172 supports scalable system configurations, allowing engineers to build modular and easily expandable control nodes. The uncoated backplane design facilitates efficient heat dissipation while maintaining robust electrical continuity across all active slots. It connects directly to system power supplies and communication links to maintain high availability and continuous data exchange throughout the plant network.

Features

  • 17 physical slots supporting high-density module placement
  • Uncoated backplane architecture optimized for controlled industrial environments
  • Integrated backplane bus for high-speed data communication between modules
  • Robust mechanical construction designed to withstand standard industrial vibration and shock
  • Direct compatibility with Honeywell Experion PKS hardware components
  • Standardized mounting profile for streamlined cabinet installation

Applications

  • Distributed Control Systems (DCS)
  • Oil and gas processing facilities
  • Chemical and petrochemical plants
  • Power generation and distribution
  • Continuous and batch manufacturing processes

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Product Model TC-FXX172
Product Type Slot Rack Chassis
Series Experion PKS
Number of Slots 17 Slots
Chassis Type Uncoated Rack Chassis
Mounting Type Standard DIN rail or panel mount (cabinet installation)
Dimensions 17.1 cm x 40.0 cm x 14.6 cm
Net Weight 1.4 kg
Country of Origin USA

Installation Guidelines

  1. Verify that the part number TC-FXX172 matches system engineering documentation prior to physical placement.
  2. De-energize all power distribution units and associated cabinet feeds before handling the chassis.
  3. Inspect the chassis and backplane pins for any shipping damage or contamination.
  4. Securely mount the chassis to the designated panel or rack using appropriate hardware, ensuring proper grounding.
  5. Install compatible Experion PKS modules into the desired slots, taking care not to bend backplane pins.
  6. Connect power supply modules and communication cables according to system architecture drawings.
  7. Apply power and verify module status indicators during system commissioning.
Loading product navigation…

What system architecture is the Honeywell TC-FXX172 designed for?

The Honeywell TC-FXX172 is specifically designed for use within Honeywell Experion PKS distributed control systems, providing the physical housing and backplane for controllers and I/O modules.

How many modules can be installed in the TC-FXX172 chassis?

The Honeywell TC-FXX172 features a 17-slot configuration, allowing up to 17 compatible system modules to be mounted and interconnected on a single backplane.

What does the uncoated designation mean for the TC-FXX172?

The uncoated designation of the Honeywell TC-FXX172 indicates that the backplane traces lack a conformal coating, making it best suited for controlled industrial environments where corrosive gases and extreme humidity are absent.

What are the physical dimensions and weight of the TC-FXX172 chassis?

The Honeywell TC-FXX172 measures 17.1 cm x 40.0 cm x 14.6 cm and has a net weight of approximately 1.4 kg.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosi degli alimentatori da 24 V CC senza inseguire guasti fantasma

Un quadro di controllo inattivo non significa automaticamente che l’alimentatore sia guasto. Questa guida sul campo utilizza controlli dell’ingresso, a vuoto, sotto carico, dell’ondulazione, del...

Una catena di segnali pratica per la misurazione e il controllo industriali

Un controllo affidabile inizia prima che il PLC esegua un ciclo. Questa guida di ingegneria segue la catena del segnale dal rilevamento e dal condizionamento fino alla trasmissione, all’azione di...

Modbus sulle reti di impianto: frame, registri e limiti di progettazione

Modbus è ancora ampiamente utilizzato perché il suo modello dati è semplice, non perché ogni implementazione lo sia. Questa guida spiega i frame, la mappatura dei registri, la temporizzazione, la...

All'interno della CPU del PLC: cicli di scansione, memoria e selezione

Una guida pratica di ingegneria al funzionamento della CPU di un PLC, dai cicli di scansione deterministici e dalle tabelle delle immagini degli I/O fino a memoria, comunicazioni, diagnostica,...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.