ProSoft

ProSoft RLX2-IHNF-A Fast Industrial Hotspot FCC Model

SKU RLX2-IHNF-A

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ProSoft
  • Product No.: RLX2-IHNF-A
  • Origin United States
  • Product Type: Industrial Wireless Hotspots
  • Payment: T/T, Western Union
  • Weight: 1.5 kg
  • Dimensions: 210 x 150 x 70 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Engineered for high-speed wireless connectivity in harsh industrial environments, the ProSoft RLX2-IHNF-A provides robust 802.11abgn Fast Industrial Hotspot capabilities under FCC regulatory frameworks. This high-reliability device is optimized for critical control networks requiring low-latency wireless bridging and client connectivity. Equipped with an extruded aluminum housing and dynamic network management capabilities, it ensures secure data transmission across complex industrial topologies.

Features

  • Multiband Flexibility: Dual-band 802.11abgn support allows configuration on both 2.4 GHz and 5 GHz bands.
  • Advanced Network Management: Supports VLAN tagging for network segmentation, Quality of Service (QoS) for packet prioritization, and IGMP Snooping to optimize multicast traffic.
  • Industrial-Grade Enclosure: Housed in a heavy-duty extruded aluminum chassis designed for high vibration and harsh thermal conditions.
  • Simplified Integration: Designed for standard 35mm DIN rail mounting, minimizing panel footprint.

Applications

  • Oil and Gas offshore and onshore production facilities requiring rugged wireless links.
  • Water and Wastewater SCADA networks for long-range, high-speed RTU communication.
  • Material Handling systems, including Automated Guided Vehicles (AGVs) requiring continuous roaming.
  • Factory Automation setups deploying decentralized wireless I/O architectures.

Technical Specifications

Manufacturer ProSoft Technology
Model Number RLX2-IHNF-A
Wireless Standards 802.11a, 802.11b, 802.11g, 802.11n
Frequency Band 2.412 GHz to 2.462 GHz (FCC Model)
Regulatory Domain FCC (Channels 1 to 11)
Network Features NAT, VLAN, QoS, IGMP Snooping
Enclosure Material Extruded Aluminum
Mounting Method DIN Rail
Net Weight 1.1 lbs (499 g)
Shipping Weight (Calculated) 1.5 kg
Package Dimensions (Calculated) 210 x 150 x 70 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The RLX2-IHNF-A is configured exclusively for the FCC regulatory domain. For European deployments, the ETSI-compliant RLX2-IHNF-E must be specified to satisfy local radio emission standards. Note that mixing FCC and ETSI hardware within the same physical subnet may result in channel mismatch issues during automatic frequency handovers.

Application Pitfalls & Engineering Notes

In highly congested industrial plants, the 2.4 GHz spectrum experiences severe attenuation and multipath interference from steel structures. To maintain optimal throughput for fast-roaming I/O devices, it is recommended to bind these critical networks to the 5 GHz band. Keep in mind that 5 GHz signals have shorter propagation distances; therefore, accurate path loss calculations are necessary when designing the physical placement of the hotspots.

Commissioning & Wiring Tips

To prevent damage from electrostatic discharge (ESD) or atmospheric surges, the DIN rail must have an uninterrupted path to the primary plant ground. Use low-loss coaxial cabling (such as LMR-400 equivalent) for any remote-mounted antenna deployments, and ensure coaxial surge protectors are installed inline and correctly grounded at the panel entry point.

Installation Guidelines

CRITICAL WARNING

De-energize all primary and secondary power supplies feeding the enclosure prior to mounting or wiring the communication hardware. Never connect or disconnect RF coaxial cables while the hotspot is powered on; doing so can cause permanent damage to the RF transmitter module.

1
Mount the unit securely onto a standard 35mm DIN rail within a clean, dry, NEMA or IP-rated industrial enclosure.
2
Connect the plant ground wire to the dedicated grounding screw on the extruded aluminum chassis before making any power or network connections.
3
Attach high-quality RP-SMA industrial antennas to the RF ports. Hand-tighten the connectors, ensuring a secure and weather-tight connection.
4
Terminate the Ethernet RJ45 network cable and connect the DC power supply, adhering strictly to the rated voltage ranges specified on the manufacturer label.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What frequency bands does this specific wireless unit support?
This FCC-certified unit operates within the 2.412 GHz to 2.462 GHz frequency band, supporting channels 1 through 11, as well as standard 5 GHz bands under FCC regulations.
Does this model support advanced network segmentation and management?
Yes, it supports key Layer 2 and Layer 3 features including VLAN tagging for network segmentation, IGMP Snooping for multicast traffic management, and Quality of Service prioritization.
What is the physical mounting requirement for this communication module?
The device features a rugged, extruded aluminum enclosure designed for standard 35mm DIN rail mounting inside industrial control panels.
Reviews

RLX2-IHNF-A

Stock & lead time on request

Call
1 su 1

ProSoft RLX2-IHNF-A Fast Industrial Hotspot FCC Model

Only 10 item(s) left in stock
  • Manufacturer: ProSoft

  • Product No.: RLX2-IHNF-A

  • Country of origin:United States

  • Product Type: Industrial Wireless Hotspots

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 210 x 150 x 70 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Engineered for high-speed wireless connectivity in harsh industrial environments, the ProSoft RLX2-IHNF-A provides robust 802.11abgn Fast Industrial Hotspot capabilities under FCC regulatory frameworks. This high-reliability device is optimized for critical control networks requiring low-latency wireless bridging and client connectivity. Equipped with an extruded aluminum housing and dynamic network management capabilities, it ensures secure data transmission across complex industrial topologies.

Features

  • Multiband Flexibility: Dual-band 802.11abgn support allows configuration on both 2.4 GHz and 5 GHz bands.
  • Advanced Network Management: Supports VLAN tagging for network segmentation, Quality of Service (QoS) for packet prioritization, and IGMP Snooping to optimize multicast traffic.
  • Industrial-Grade Enclosure: Housed in a heavy-duty extruded aluminum chassis designed for high vibration and harsh thermal conditions.
  • Simplified Integration: Designed for standard 35mm DIN rail mounting, minimizing panel footprint.

Applications

  • Oil and Gas offshore and onshore production facilities requiring rugged wireless links.
  • Water and Wastewater SCADA networks for long-range, high-speed RTU communication.
  • Material Handling systems, including Automated Guided Vehicles (AGVs) requiring continuous roaming.
  • Factory Automation setups deploying decentralized wireless I/O architectures.

Technical Specifications

Manufacturer ProSoft Technology
Model Number RLX2-IHNF-A
Wireless Standards 802.11a, 802.11b, 802.11g, 802.11n
Frequency Band 2.412 GHz to 2.462 GHz (FCC Model)
Regulatory Domain FCC (Channels 1 to 11)
Network Features NAT, VLAN, QoS, IGMP Snooping
Enclosure Material Extruded Aluminum
Mounting Method DIN Rail
Net Weight 1.1 lbs (499 g)
Shipping Weight (Calculated) 1.5 kg
Package Dimensions (Calculated) 210 x 150 x 70 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The RLX2-IHNF-A is configured exclusively for the FCC regulatory domain. For European deployments, the ETSI-compliant RLX2-IHNF-E must be specified to satisfy local radio emission standards. Note that mixing FCC and ETSI hardware within the same physical subnet may result in channel mismatch issues during automatic frequency handovers.

Application Pitfalls & Engineering Notes

In highly congested industrial plants, the 2.4 GHz spectrum experiences severe attenuation and multipath interference from steel structures. To maintain optimal throughput for fast-roaming I/O devices, it is recommended to bind these critical networks to the 5 GHz band. Keep in mind that 5 GHz signals have shorter propagation distances; therefore, accurate path loss calculations are necessary when designing the physical placement of the hotspots.

Commissioning & Wiring Tips

To prevent damage from electrostatic discharge (ESD) or atmospheric surges, the DIN rail must have an uninterrupted path to the primary plant ground. Use low-loss coaxial cabling (such as LMR-400 equivalent) for any remote-mounted antenna deployments, and ensure coaxial surge protectors are installed inline and correctly grounded at the panel entry point.

Installation Guidelines

CRITICAL WARNING

De-energize all primary and secondary power supplies feeding the enclosure prior to mounting or wiring the communication hardware. Never connect or disconnect RF coaxial cables while the hotspot is powered on; doing so can cause permanent damage to the RF transmitter module.

1
Mount the unit securely onto a standard 35mm DIN rail within a clean, dry, NEMA or IP-rated industrial enclosure.
2
Connect the plant ground wire to the dedicated grounding screw on the extruded aluminum chassis before making any power or network connections.
3
Attach high-quality RP-SMA industrial antennas to the RF ports. Hand-tighten the connectors, ensuring a secure and weather-tight connection.
4
Terminate the Ethernet RJ45 network cable and connect the DC power supply, adhering strictly to the rated voltage ranges specified on the manufacturer label.

What frequency bands does this specific wireless unit support?

This FCC-certified unit operates within the 2.412 GHz to 2.462 GHz frequency band, supporting channels 1 through 11, as well as standard 5 GHz bands under FCC regulations.

Does this model support advanced network segmentation and management?

Yes, it supports key Layer 2 and Layer 3 features including VLAN tagging for network segmentation, IGMP Snooping for multicast traffic management, and Quality of Service prioritization.

What is the physical mounting requirement for this communication module?

The device features a rugged, extruded aluminum enclosure designed for standard 35mm DIN rail mounting inside industrial control panels.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...