Schneider Electric

Schneider Altistart 22 ATS22C14S6U Soft Starter

SKU ATS22C14S6U

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric
  • Product No.: ATS22C14S6U
  • Origin France
  • Product Type: Soft starters
  • Payment: T/T, Western Union
  • Weight: 13.21 kg
  • Dimensions: 41cm x 33cm x 25cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The ATS22C14S6U is an Altistart 22 soft starter designed for the controlled starting and stopping of three-phase asynchronous motors. This unit provides current-limiting and voltage-ramping capabilities to reduce mechanical stress on drive trains and minimize inrush current during startup. It is engineered for industrial applications requiring smooth motor acceleration and deceleration to protect equipment and optimize power distribution.

Features

  • Rated for 140 A operation
  • Supports voltage range from 208V to 600V
  • Motor power range: 40 to 125 HP
  • Integrated bypass contactor for reduced heat dissipation
  • Compact physical footprint for space-constrained enclosures
  • Diagnostic and testing capabilities for maintenance efficiency

Applications

  • Centrifugal pumps
  • Fan and blower systems
  • Compressors
  • Conveyor belts
  • General machinery requiring soft-start torque control

Technical Specifications

Specification Details
Manufacturer Schneider Electric
Range Altistart 22
Product Type Soft starter
Rated Current 140 A
Voltage Range 208-600 V
Motor Power Rating 40 - 125 HP
Dimensions 41 x 33 x 25 cm
Weight 13.21 kg
Commodity Code 84798997
Product Status Active

Installation Guidelines

  • Mounting: Ensure the unit is mounted vertically on a flat, rigid surface to allow for proper airflow.
  • Cooling: Maintain recommended clearance distances around the unit to prevent thermal overload. Refer to the manual for specific ambient temperature derating requirements.
  • Wiring: Use appropriately sized power cables based on the 140 A rating. Ensure all terminals are tightened to the specified torque values to prevent resistive heating.
  • Grounding: Proper equipment grounding is required for safe operation and electromagnetic compatibility.
  • Environment: Protect the device from moisture, excessive dust, and corrosive gases to maintain operational longevity.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the ATS22C14S6U soft starter?
It controls the starting and stopping of asynchronous motors by providing a controlled voltage ramp, which reduces mechanical shock and limits inrush current.
What is the motor power range supported by this model?
This unit is designed for motors ranging from 40 HP to 125 HP, depending on the supply voltage.
Does the ATS22C14S6U include an internal bypass?
Yes, the Altistart 22 series features an integrated bypass contactor to reduce internal power dissipation during steady-state operation.
What are the physical dimensions of this unit for cabinet planning?
The dimensions of the device are 41 cm by 33 cm by 25 cm.
Reviews

ATS22C14S6U

Stock & lead time on request

Call
1 su 1

Schneider Altistart 22 ATS22C14S6U Soft Starter

Only 8 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATS22C14S6U

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 13210g

  • Dimensions: 41cm x 33cm x 25cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The ATS22C14S6U is an Altistart 22 soft starter designed for the controlled starting and stopping of three-phase asynchronous motors. This unit provides current-limiting and voltage-ramping capabilities to reduce mechanical stress on drive trains and minimize inrush current during startup. It is engineered for industrial applications requiring smooth motor acceleration and deceleration to protect equipment and optimize power distribution.

Features

  • Rated for 140 A operation
  • Supports voltage range from 208V to 600V
  • Motor power range: 40 to 125 HP
  • Integrated bypass contactor for reduced heat dissipation
  • Compact physical footprint for space-constrained enclosures
  • Diagnostic and testing capabilities for maintenance efficiency

Applications

  • Centrifugal pumps
  • Fan and blower systems
  • Compressors
  • Conveyor belts
  • General machinery requiring soft-start torque control

Technical Specifications

Specification Details
Manufacturer Schneider Electric
Range Altistart 22
Product Type Soft starter
Rated Current 140 A
Voltage Range 208-600 V
Motor Power Rating 40 - 125 HP
Dimensions 41 x 33 x 25 cm
Weight 13.21 kg
Commodity Code 84798997
Product Status Active

Installation Guidelines

  • Mounting: Ensure the unit is mounted vertically on a flat, rigid surface to allow for proper airflow.
  • Cooling: Maintain recommended clearance distances around the unit to prevent thermal overload. Refer to the manual for specific ambient temperature derating requirements.
  • Wiring: Use appropriately sized power cables based on the 140 A rating. Ensure all terminals are tightened to the specified torque values to prevent resistive heating.
  • Grounding: Proper equipment grounding is required for safe operation and electromagnetic compatibility.
  • Environment: Protect the device from moisture, excessive dust, and corrosive gases to maintain operational longevity.

What is the primary function of the ATS22C14S6U soft starter?

It controls the starting and stopping of asynchronous motors by providing a controlled voltage ramp, which reduces mechanical shock and limits inrush current.

What is the motor power range supported by this model?

This unit is designed for motors ranging from 40 HP to 125 HP, depending on the supply voltage.

Does the ATS22C14S6U include an internal bypass?

Yes, the Altistart 22 series features an integrated bypass contactor to reduce internal power dissipation during steady-state operation.

What are the physical dimensions of this unit for cabinet planning?

The dimensions of the device are 41 cm by 33 cm by 25 cm.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
AC-powered

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.