Schneider Electric

Schneider ATS22C14S6 Altistart 22 Soft Starter

SKU ATS22C14S6

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric
  • Product No.: ATS22C14S6
  • Origin France
  • Product Type: Soft starters
  • Payment: T/T, Western Union
  • Weight: 13.32 kg
  • Dimensions: 41cm x 33cm x 25cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The ATS22C14S6 is an Altistart 22 soft starter manufactured by Schneider Electric, engineered for the controlled starting and stopping of 3-phase asynchronous motors. This unit is designed to mitigate mechanical stress and electrical surges during motor start-up by reducing inrush current, thereby extending the operational lifespan of the motor and connected drive train components.

The soft starter supports a wide voltage range of 230 V to 600 V and is capable of managing motor power ratings between 37 kW and 90 kW, with a rated operational current of 140 A. Its compact design allows for efficient installation in control cabinets, while its integrated bypass functionality optimizes energy consumption and minimizes heat dissipation during steady-state operation.

Features

  • Altistart 22 series soft starter
  • Rated current: 140 A
  • Supports motor power range: 37 kW to 90 kW
  • Wide input voltage range: 230–600 V AC
  • Reduces inrush current and mechanical starting stress
  • Integrated bypass for optimized energy efficiency
  • Compact dimensions for flexible cabinet installation

Applications

  • Pump and fan control systems
  • Conveyor belts and material handling equipment
  • Centrifugal machines and mixers
  • General industrial motor applications requiring smooth acceleration

Technical Specifications

Feature Specification
Brand Schneider Electric
Range Altistart
Subrange 22
Product Type Soft Starter
Rated Current 140 A
Power Rating 37–90 kW
Input Voltage 230–600 V AC
Weight 13.32 kg
Dimensions 41.00 cm x 33.00 cm x 25.00 cm
Product Phase Active
Commodity Code 84798997

Installation Guidelines

  • Mounting: Install the soft starter vertically in a clean, ventilated control cabinet. Ensure sufficient clearance above and below the unit for heat dissipation.
  • Environment: The installation location must be free from conductive dust, corrosive gases, and extreme humidity to ensure long-term reliability.
  • Wiring: Connect the power input and motor output terminals according to the specific motor voltage and kW rating. Utilize torque-rated tools for all terminal connections.
  • Grounding: Maintain a high-integrity connection to the system's protective earth (PE) busbar to ensure electromagnetic compatibility and safety.
  • Settings: Configure the starting ramp and torque limiting parameters via the front interface or configuration software to match the specific load requirements of the application.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the rated current for the ATS22C14S6?
The rated operational current for this unit is 140 A.
What power range does this soft starter support?
It is designed to support asynchronous motors with power ratings between 37 kW and 90 kW.
Does this unit help with motor start-up stress?
Yes, by reducing inrush current, the soft starter minimizes mechanical and electrical stress on the motor during start-up.
What is the input voltage range of the soft starter?
The soft starter supports an input voltage range of 230 V to 600 V AC.
Reviews

ATS22C14S6

Stock & lead time on request

Call
1 su 1

Schneider ATS22C14S6 Altistart 22 Soft Starter

Only 9 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATS22C14S6

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 13320g

  • Dimensions: 41cm x 33cm x 25cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The ATS22C14S6 is an Altistart 22 soft starter manufactured by Schneider Electric, engineered for the controlled starting and stopping of 3-phase asynchronous motors. This unit is designed to mitigate mechanical stress and electrical surges during motor start-up by reducing inrush current, thereby extending the operational lifespan of the motor and connected drive train components.

The soft starter supports a wide voltage range of 230 V to 600 V and is capable of managing motor power ratings between 37 kW and 90 kW, with a rated operational current of 140 A. Its compact design allows for efficient installation in control cabinets, while its integrated bypass functionality optimizes energy consumption and minimizes heat dissipation during steady-state operation.

Features

  • Altistart 22 series soft starter
  • Rated current: 140 A
  • Supports motor power range: 37 kW to 90 kW
  • Wide input voltage range: 230–600 V AC
  • Reduces inrush current and mechanical starting stress
  • Integrated bypass for optimized energy efficiency
  • Compact dimensions for flexible cabinet installation

Applications

  • Pump and fan control systems
  • Conveyor belts and material handling equipment
  • Centrifugal machines and mixers
  • General industrial motor applications requiring smooth acceleration

Technical Specifications

Feature Specification
Brand Schneider Electric
Range Altistart
Subrange 22
Product Type Soft Starter
Rated Current 140 A
Power Rating 37–90 kW
Input Voltage 230–600 V AC
Weight 13.32 kg
Dimensions 41.00 cm x 33.00 cm x 25.00 cm
Product Phase Active
Commodity Code 84798997

Installation Guidelines

  • Mounting: Install the soft starter vertically in a clean, ventilated control cabinet. Ensure sufficient clearance above and below the unit for heat dissipation.
  • Environment: The installation location must be free from conductive dust, corrosive gases, and extreme humidity to ensure long-term reliability.
  • Wiring: Connect the power input and motor output terminals according to the specific motor voltage and kW rating. Utilize torque-rated tools for all terminal connections.
  • Grounding: Maintain a high-integrity connection to the system's protective earth (PE) busbar to ensure electromagnetic compatibility and safety.
  • Settings: Configure the starting ramp and torque limiting parameters via the front interface or configuration software to match the specific load requirements of the application.
Key Features:

What is the rated current for the ATS22C14S6?

The rated operational current for this unit is 140 A.

What power range does this soft starter support?

It is designed to support asynchronous motors with power ratings between 37 kW and 90 kW.

Does this unit help with motor start-up stress?

Yes, by reducing inrush current, the soft starter minimizes mechanical and electrical stress on the motor during start-up.

What is the input voltage range of the soft starter?

The soft starter supports an input voltage range of 230 V to 600 V AC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
AC-powered

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.