Siemens

Siemens 6DS1403-8CB Teleperm Controller Module

SKU 6DS1403-8CB

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens
  • Product No.: 6DS1403-8CB
  • Origin Germany
  • Product Type: Controller Module
  • Barcode: 85389091
  • Payment: T/T, Western Union
  • Weight: 0.51 kg
  • Dimensions: 26.20cm x 20.80cm x 4.50cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

The 6DS1403-8CB is a specialized controller module from the Siemens TELEPERM series, engineered for precise closed-loop process control. This unit features two integrated PI (Proportional-Integral) controllers with 2-channel functionality. A key technical feature is the support for the NAMUR failure signal level, specifically configured for a range of 3.6 mA to 21 mA. This capability ensures reliable signal monitoring and fault detection in industrial control loops.

Features

  • Control Type: Dual PI (Proportional-Integral) closed-loop controllers.
  • Channel Configuration: 2-channel control architecture.
  • Signal Compatibility: Supports NAMUR failure signal level standard (3.6 mA/21 mA).
  • Architecture: Designed for seamless integration into TELEPERM control systems.
  • Reliability: Built to maintain stable process regulation in demanding industrial environments.

Applications

  • Process automation in chemical and manufacturing plants.
  • Closed-loop regulation of temperature, pressure, or flow control loops.
  • Integration into legacy TELEPERM automation architectures.
  • Industrial monitoring systems requiring NAMUR signal fault detection.

Technical Specifications

Attribute Specification
Manufacturer Siemens
Product Range Teleperm
Controller Type 2 x PI Controls
Channels 2-channel
Failure Signal Level NAMUR (3.6 mA / 21 mA)
Dimensions (WxHxD) 26.20 x 20.80 x 4.50 cm
Weight 0.51 kg
Commodity Code 85389091

Installation Guidelines

  • Mounting: Install the module in a suitable rack or housing designed for the TELEPERM series. Ensure secure engagement with the backplane connectors to maintain stable electrical contact.
  • Signal Wiring: Adhere to standard instrumentation wiring practices for 4-20 mA loops. Verify that the current signal output falls within the 3.6 mA to 21 mA range to correctly trigger NAMUR fault signaling.
  • Environment: Protect the module from exposure to excessive heat, moisture, or corrosive industrial atmospheres to prevent premature degradation of electronic components.
  • Calibration: Periodically verify the PI control parameters and signal thresholds to ensure the control loop maintains specified performance accuracy.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What does the NAMUR signal level support imply for this module?
It allows the module to detect and signal fault conditions specifically within the 3.6 mA to 21 mA range, following industry-standard NAMUR failure signaling.
How many control channels does the 6DS1403-8CB provide?
This module features 2 channels with dual PI controllers.
Is the 6DS1403-8CB suitable for modern automation systems?
This is part of the legacy Teleperm series and is primarily used for maintenance or replacement within existing TELEPERM-based control architectures.
Reviews

6DS1403-8CB

Stock & lead time on request

Call
1 su 1

Siemens 6DS1403-8CB Teleperm Controller Module

Only 5 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6DS1403-8CB

  • Country of origin:Germany

  • Product Type: Controller Module

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 510g

  • Dimensions: 26.20cm x 20.80cm x 4.50cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

The 6DS1403-8CB is a specialized controller module from the Siemens TELEPERM series, engineered for precise closed-loop process control. This unit features two integrated PI (Proportional-Integral) controllers with 2-channel functionality. A key technical feature is the support for the NAMUR failure signal level, specifically configured for a range of 3.6 mA to 21 mA. This capability ensures reliable signal monitoring and fault detection in industrial control loops.

Features

  • Control Type: Dual PI (Proportional-Integral) closed-loop controllers.
  • Channel Configuration: 2-channel control architecture.
  • Signal Compatibility: Supports NAMUR failure signal level standard (3.6 mA/21 mA).
  • Architecture: Designed for seamless integration into TELEPERM control systems.
  • Reliability: Built to maintain stable process regulation in demanding industrial environments.

Applications

  • Process automation in chemical and manufacturing plants.
  • Closed-loop regulation of temperature, pressure, or flow control loops.
  • Integration into legacy TELEPERM automation architectures.
  • Industrial monitoring systems requiring NAMUR signal fault detection.

Technical Specifications

Attribute Specification
Manufacturer Siemens
Product Range Teleperm
Controller Type 2 x PI Controls
Channels 2-channel
Failure Signal Level NAMUR (3.6 mA / 21 mA)
Dimensions (WxHxD) 26.20 x 20.80 x 4.50 cm
Weight 0.51 kg
Commodity Code 85389091

Installation Guidelines

  • Mounting: Install the module in a suitable rack or housing designed for the TELEPERM series. Ensure secure engagement with the backplane connectors to maintain stable electrical contact.
  • Signal Wiring: Adhere to standard instrumentation wiring practices for 4-20 mA loops. Verify that the current signal output falls within the 3.6 mA to 21 mA range to correctly trigger NAMUR fault signaling.
  • Environment: Protect the module from exposure to excessive heat, moisture, or corrosive industrial atmospheres to prevent premature degradation of electronic components.
  • Calibration: Periodically verify the PI control parameters and signal thresholds to ensure the control loop maintains specified performance accuracy.
Key Features:

What does the NAMUR signal level support imply for this module?

It allows the module to detect and signal fault conditions specifically within the 3.6 mA to 21 mA range, following industry-standard NAMUR failure signaling.

How many control channels does the 6DS1403-8CB provide?

This module features 2 channels with dual PI controllers.

Is the 6DS1403-8CB suitable for modern automation systems?

This is part of the legacy Teleperm series and is primarily used for maintenance or replacement within existing TELEPERM-based control architectures.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
Germany
Power source
DC Power

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...