Siemens

Siemens 6ES7710-5CA14-3FB3 SIMATIC Field PG Programming Device

SKU 6ES7710-5CA14-3FB3

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens
  • Product No.: 6ES7710-5CA14-3FB3
  • Origin Germany
  • Product Type: Programming Device
  • Barcode: 84713000
  • Payment: T/T, Western Union
  • Weight: 0.004 kg
  • Dimensions: 29.00 x 25.00 x 25.00 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The Siemens 6ES7710-5CA14-3FB3 is a SIMATIC Field PG based on a Pentium III 1 GHz processor, designed for industrial programming and diagnostic tasks. It features 256 KB 2nd level cache, 128 MB SDRAM, a 20 GB EIDE HDD, and integrated DVD/CD ROM and 1.44 MB floppy disk drives. Pre-installed with Windows 2000 MUI GEFSI and various STEP software versions (STEP 7, STEP 5, STEP 7 MicroWIN) from June 2002, this programming device is equipped with a power cable suitable for specific European regions (Germany, France, Netherlands, Spain, Belgium, Austria, Sweden, Finland).

Features

  • Pentium III 1 GHz Processor
  • 256 KB 2nd Level Cache
  • 128 MB SDRAM (1x128 MB)
  • 20 GB EIDE Hard Disk Drive (HDD)
  • Integrated DVD / CD ROM Drive
  • Integrated 1.44 MB Floppy Disk Drive
  • Pre-installed Windows 2000 MUI GEFSI
  • Pre-installed STEP 7, STEP 5, STEP 7 MicroWIN Software (06/2002)
  • Includes power cable for GER, FR, NL, SP, BEL, AUSTRIA, SWD, FIN

Applications

  • Programming and configuration of Siemens SIMATIC PLCs (S7, S5).
  • Diagnostic and troubleshooting for industrial automation systems.
  • On-site commissioning and maintenance tasks for industrial control systems.
  • Support for legacy SIMATIC installations requiring older software versions.

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range SIMATIC Field PG
Subrange Field PG
Product Type Programming Device (Pentium 3)
Processor Pentium III 1 GHz
Cache 256 KB 2nd Level Cache
RAM 128 MB SDRAM (1x128 MB)
Hard Disk Drive 20 GB EIDE HDD
Optical Drive DVD / CD ROM Drive
Floppy Drive 1.44 MB Floppy Disk Drive
Operating System Windows 2000 MUI GEFSI
Pre-installed Software STEP 7, STEP 5, STEP 7 MicroWIN (06/2002)
Included Accessories Power cable for GER, FR, NL, SP, BEL, AUSTRIA, SWD, FIN
Product Phase Obsolete
Package Dimensions (Calculated) 29.00 x 25.00 x 25.00 cm
Shipping Weight 4.00 kg
Commodity Code 84713000
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Power Connection: Connect the device to a suitable power outlet using the provided power cable. Ensure the power supply matches the requirements for the specific region.
  2. Environmental Considerations: Operate the Field PG in a clean, dry environment within its specified temperature and humidity ranges (if available). Protect it from excessive dust, moisture, and vibration.
  3. Software Verification: Before connecting to any industrial system, verify the integrity and version of the pre-installed STEP software. Ensure compatibility with the target PLC or automation component.
  4. Data Transfer: Utilize the integrated DVD/CD ROM or floppy disk drive for loading or saving program files. For network communication, ensure proper network settings and drivers are configured.
  5. Safety Precautions: Always de-energize the target industrial system before connecting or disconnecting communication cables to the Field PG to prevent electrical hazards or damage to equipment.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the 6ES7710-5CA14-3FB3?
It serves as a portable programming and diagnostic device for Siemens SIMATIC PLCs, supporting STEP 7, STEP 5, and STEP 7 MicroWIN software.
What operating system is pre-installed on this Field PG?
The device comes with Windows 2000 MUI GEFSI pre-installed.
Can this Field PG connect to older SIMATIC S5 systems?
Yes, it supports older SIMATIC S5 systems through its pre-installed STEP 5 software.
What are the main storage and optical drive features?
It includes a 20 GB EIDE HDD, a DVD/CD ROM drive, and a 1.44 MB floppy disk drive.
Reviews

6ES7710-5CA14-3FB3

Stock & lead time on request

Call
1 su 1

Siemens 6ES7710-5CA14-3FB3 SIMATIC Field PG Programming Device

Only 6 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7710-5CA14-3FB3

  • Country of origin:Germany

  • Product Type: Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 29.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Siemens 6ES7710-5CA14-3FB3 is a SIMATIC Field PG based on a Pentium III 1 GHz processor, designed for industrial programming and diagnostic tasks. It features 256 KB 2nd level cache, 128 MB SDRAM, a 20 GB EIDE HDD, and integrated DVD/CD ROM and 1.44 MB floppy disk drives. Pre-installed with Windows 2000 MUI GEFSI and various STEP software versions (STEP 7, STEP 5, STEP 7 MicroWIN) from June 2002, this programming device is equipped with a power cable suitable for specific European regions (Germany, France, Netherlands, Spain, Belgium, Austria, Sweden, Finland).

Features

  • Pentium III 1 GHz Processor
  • 256 KB 2nd Level Cache
  • 128 MB SDRAM (1x128 MB)
  • 20 GB EIDE Hard Disk Drive (HDD)
  • Integrated DVD / CD ROM Drive
  • Integrated 1.44 MB Floppy Disk Drive
  • Pre-installed Windows 2000 MUI GEFSI
  • Pre-installed STEP 7, STEP 5, STEP 7 MicroWIN Software (06/2002)
  • Includes power cable for GER, FR, NL, SP, BEL, AUSTRIA, SWD, FIN

Applications

  • Programming and configuration of Siemens SIMATIC PLCs (S7, S5).
  • Diagnostic and troubleshooting for industrial automation systems.
  • On-site commissioning and maintenance tasks for industrial control systems.
  • Support for legacy SIMATIC installations requiring older software versions.

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range SIMATIC Field PG
Subrange Field PG
Product Type Programming Device (Pentium 3)
Processor Pentium III 1 GHz
Cache 256 KB 2nd Level Cache
RAM 128 MB SDRAM (1x128 MB)
Hard Disk Drive 20 GB EIDE HDD
Optical Drive DVD / CD ROM Drive
Floppy Drive 1.44 MB Floppy Disk Drive
Operating System Windows 2000 MUI GEFSI
Pre-installed Software STEP 7, STEP 5, STEP 7 MicroWIN (06/2002)
Included Accessories Power cable for GER, FR, NL, SP, BEL, AUSTRIA, SWD, FIN
Product Phase Obsolete
Package Dimensions (Calculated) 29.00 x 25.00 x 25.00 cm
Shipping Weight 4.00 kg
Commodity Code 84713000
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Power Connection: Connect the device to a suitable power outlet using the provided power cable. Ensure the power supply matches the requirements for the specific region.
  2. Environmental Considerations: Operate the Field PG in a clean, dry environment within its specified temperature and humidity ranges (if available). Protect it from excessive dust, moisture, and vibration.
  3. Software Verification: Before connecting to any industrial system, verify the integrity and version of the pre-installed STEP software. Ensure compatibility with the target PLC or automation component.
  4. Data Transfer: Utilize the integrated DVD/CD ROM or floppy disk drive for loading or saving program files. For network communication, ensure proper network settings and drivers are configured.
  5. Safety Precautions: Always de-energize the target industrial system before connecting or disconnecting communication cables to the Field PG to prevent electrical hazards or damage to equipment.

What is the primary function of the 6ES7710-5CA14-3FB3?

It serves as a portable programming and diagnostic device for Siemens SIMATIC PLCs, supporting STEP 7, STEP 5, and STEP 7 MicroWIN software.

What operating system is pre-installed on this Field PG?

The device comes with Windows 2000 MUI GEFSI pre-installed.

Can this Field PG connect to older SIMATIC S5 systems?

Yes, it supports older SIMATIC S5 systems through its pre-installed STEP 5 software.

What are the main storage and optical drive features?

It includes a 20 GB EIDE HDD, a DVD/CD ROM drive, and a 1.44 MB floppy disk drive.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...