Siemens

Siemens 6ES7716-2CA16-0CD2 SIMATIC Field PG M4 Industrial Programming Device

SKU 6ES7716-2CA16-0CD2

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens
  • Product No.: 6ES7716-2CA16-0CD2
  • Origin Germany
  • Product Type: Industrial Programming Device
  • Barcode: 84713000
  • Payment: T/T, Western Union
  • Weight: 3.5 kg
  • Dimensions: 39.50 x 30.00 x 17.00 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The Siemens 6ES7716-2CA16-0CD2 is a SIMATIC Field PG M4 Premium industrial programming device designed for engineering and commissioning tasks within automation environments. This promotional package features a Solid-State Drive (SSD) with 300 GB capacity, a 15.6-inch Full HD (1920x1080) display, and an AZERTY keyboard layout. It comes pre-installed with Windows 7 Ultimate SP1 (64-bit) and is equipped with 16 GB RAM (2x 8 GB). The device includes an MPI cable and a power supply cable for EU regions. Software licenses for STEP 7 Professional V12 and WinCC Advanced V12 are provided, enabling comprehensive PLC and HMI programming capabilities. This specific configuration does not include an S5 interface or an S5-EPROMMER.

Features

  • Solid-State Drive (SSD) SATA 300 GB
  • 15.6" Full HD (1920x1080) Display
  • AZERTY Keyboard Layout
  • Pre-installed Windows 7 Ultimate SP1, 64-bit Operating System
  • 16 GB RAM (2x 8 GB)
  • Includes MPI Communication Cable
  • Includes Power Supply Cable for EU
  • Licenses for STEP 7 Professional V12 and WinCC Advanced V12
  • No S5 Interface or S5-EPROMMER

Applications

  • PLC programming and configuration
  • HMI design and visualization setup
  • Industrial system commissioning and startup
  • On-site diagnostics and troubleshooting
  • Maintenance and service tasks for automation systems
  • Software updates and parameter adjustments for industrial controllers

Ordering Information

Model Description
6ES7716-2CA16-0CD2 SIMATIC Field PG M4 Premium Industrial Programming Device, Promotional Package

Technical Specifications

Parameter Value
Manufacturer Siemens
Range Simatic Field PG
Subrange Field PG M4
Product Type Premium Industrial Programming Device
Storage Solid-State Drive (SSD) SATA 300 GB
Display Size 15.6"
Display Resolution Full HD (1920x1080)
Keyboard Layout AZERTY
Operating System Windows 7 Ultimate SP1, 64 bit
RAM 2x 8 GB (16 GB total)
S5 Interface Without
S5-EPROMMER Without
Included Cables MPI cable, Power supply cable for EU
Included Software Licenses STEP 7 Prof. V12, WinCC Advanced V12
Product Phase Obsolete
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.50 kg
Commodity Code 84713000
Export Control Regulations (ECCN) 5A992

Connections / Interfaces

  • MPI (Multi-Point Interface) for PLC communication
  • Standard peripheral interfaces (e.g., USB, Ethernet) typical for a laptop of this generation (not explicitly detailed in source)
  • No S5 interface

Installation Guidelines

  1. Power Connection: Connect the provided power supply cable to a suitable EU standard electrical outlet. Ensure the power source meets the device's electrical requirements.
  2. Initial Setup: Upon first power-on, follow the on-screen prompts for Windows 7 Ultimate SP1 setup and configuration.
  3. Software Installation: Verify that STEP 7 Professional V12 and WinCC Advanced V12 are correctly installed and licensed. Perform any necessary updates for the operating system and engineering software.
  4. Peripheral Connections: Connect necessary peripherals such as external monitors, mice, or keyboards as required for the engineering task.
  5. Communication Setup: Utilize the included MPI cable to establish communication with SIMATIC PLCs. Configure the MPI interface settings within the engineering software.
  6. Environmental Considerations: Operate the device within typical industrial office or control room environments. Avoid exposure to extreme temperatures, excessive dust, or moisture.
  7. Data Security: Implement appropriate data backup procedures for project files and system configurations.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What software licenses are included with this Field PG?
The device includes licenses for STEP 7 Professional V12 and WinCC Advanced V12.
Does this Field PG support older S5 PLCs?
No, this specific configuration is noted as being without an S5 interface and without an S5-EPROMMER.
What is the operating system installed on the device?
It comes pre-installed with Windows 7 Ultimate SP1, 64-bit.
What type of storage does the Field PG M4 use?
It features a 300 GB SATA Solid-State Drive (SSD).
Is an MPI cable included with the programming device?
Yes, an MPI cable is included for communication with SIMATIC PLCs.
Reviews

6ES7716-2CA16-0CD2

Stock & lead time on request

Call
1 su 1

Siemens 6ES7716-2CA16-0CD2 SIMATIC Field PG M4 Industrial Programming Device

Only 7 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7716-2CA16-0CD2

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.50 x 30.00 x 17.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Siemens 6ES7716-2CA16-0CD2 is a SIMATIC Field PG M4 Premium industrial programming device designed for engineering and commissioning tasks within automation environments. This promotional package features a Solid-State Drive (SSD) with 300 GB capacity, a 15.6-inch Full HD (1920x1080) display, and an AZERTY keyboard layout. It comes pre-installed with Windows 7 Ultimate SP1 (64-bit) and is equipped with 16 GB RAM (2x 8 GB). The device includes an MPI cable and a power supply cable for EU regions. Software licenses for STEP 7 Professional V12 and WinCC Advanced V12 are provided, enabling comprehensive PLC and HMI programming capabilities. This specific configuration does not include an S5 interface or an S5-EPROMMER.

Features

  • Solid-State Drive (SSD) SATA 300 GB
  • 15.6" Full HD (1920x1080) Display
  • AZERTY Keyboard Layout
  • Pre-installed Windows 7 Ultimate SP1, 64-bit Operating System
  • 16 GB RAM (2x 8 GB)
  • Includes MPI Communication Cable
  • Includes Power Supply Cable for EU
  • Licenses for STEP 7 Professional V12 and WinCC Advanced V12
  • No S5 Interface or S5-EPROMMER

Applications

  • PLC programming and configuration
  • HMI design and visualization setup
  • Industrial system commissioning and startup
  • On-site diagnostics and troubleshooting
  • Maintenance and service tasks for automation systems
  • Software updates and parameter adjustments for industrial controllers

Ordering Information

Model Description
6ES7716-2CA16-0CD2 SIMATIC Field PG M4 Premium Industrial Programming Device, Promotional Package

Technical Specifications

Parameter Value
Manufacturer Siemens
Range Simatic Field PG
Subrange Field PG M4
Product Type Premium Industrial Programming Device
Storage Solid-State Drive (SSD) SATA 300 GB
Display Size 15.6"
Display Resolution Full HD (1920x1080)
Keyboard Layout AZERTY
Operating System Windows 7 Ultimate SP1, 64 bit
RAM 2x 8 GB (16 GB total)
S5 Interface Without
S5-EPROMMER Without
Included Cables MPI cable, Power supply cable for EU
Included Software Licenses STEP 7 Prof. V12, WinCC Advanced V12
Product Phase Obsolete
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.50 kg
Commodity Code 84713000
Export Control Regulations (ECCN) 5A992

Connections / Interfaces

  • MPI (Multi-Point Interface) for PLC communication
  • Standard peripheral interfaces (e.g., USB, Ethernet) typical for a laptop of this generation (not explicitly detailed in source)
  • No S5 interface

Installation Guidelines

  1. Power Connection: Connect the provided power supply cable to a suitable EU standard electrical outlet. Ensure the power source meets the device's electrical requirements.
  2. Initial Setup: Upon first power-on, follow the on-screen prompts for Windows 7 Ultimate SP1 setup and configuration.
  3. Software Installation: Verify that STEP 7 Professional V12 and WinCC Advanced V12 are correctly installed and licensed. Perform any necessary updates for the operating system and engineering software.
  4. Peripheral Connections: Connect necessary peripherals such as external monitors, mice, or keyboards as required for the engineering task.
  5. Communication Setup: Utilize the included MPI cable to establish communication with SIMATIC PLCs. Configure the MPI interface settings within the engineering software.
  6. Environmental Considerations: Operate the device within typical industrial office or control room environments. Avoid exposure to extreme temperatures, excessive dust, or moisture.
  7. Data Security: Implement appropriate data backup procedures for project files and system configurations.

What software licenses are included with this Field PG?

The device includes licenses for STEP 7 Professional V12 and WinCC Advanced V12.

Does this Field PG support older S5 PLCs?

No, this specific configuration is noted as being without an S5 interface and without an S5-EPROMMER.

What is the operating system installed on the device?

It comes pre-installed with Windows 7 Ultimate SP1, 64-bit.

What type of storage does the Field PG M4 use?

It features a 300 GB SATA Solid-State Drive (SSD).

Is an MPI cable included with the programming device?

Yes, an MPI cable is included for communication with SIMATIC PLCs.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...