Weidmuller

Weidmuller 8965370000 ACT20X-2HDI-2SDO-RNO-S Isolating Switch Amplifiers

SKU 8965370000

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Weidmuller
  • Product No.: 8965370000
  • Origin Germany
  • Product Type: Isolating Switch Amplifiers
  • Payment: T/T, Western Union
  • Weight: 0.19 kg
  • Dimensions: 117.2 mm x 22.5 mm x 113.6 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Designed for intrinsic safety applications, the Weidmuller 8965370000 functions as a highly reliable isolating switch amplifier to transmit digital signals from hazardous areas (Zone 0, 1, 2) to safe areas. This 2-channel module is engineered to process signals from NAMUR sensors or mechanical contacts located in explosive atmospheres, providing complete galvanic isolation between the input, output, power supply, and alarm contacts.

The ACT20X-2HDI-2SDO-RNO-S features integrated line fault detection (LFD) to monitor the input circuits for wire breaks or short circuits. In the event of a fault, the device triggers an alarm relay, ensuring rapid diagnostics and minimizing system downtime. Configuration is easily managed via standard FDT/DTM software, allowing precise customization of operational parameters to match specific process requirements.

Features

  • Dual-channel signal isolation and transmission from Ex to non-Ex zones.
  • Intrinsically safe input circuits compatible with NAMUR sensors and mechanical switches.
  • Two normally open (NO) relay outputs for reliable signal switching.
  • Comprehensive line fault detection (LFD) for short-circuit and wire-break monitoring.
  • FDT/DTM software configuration for flexible parameter adjustment.
  • Complete galvanic isolation between input, output, power supply, and alarm contacts.
  • Compact 22.5 mm DIN-rail mountable housing to optimize cabinet space.

Applications

  • Chemical and petrochemical processing plants.
  • Oil and gas extraction, refining, and distribution facilities.
  • Water and wastewater treatment automation.
  • Hazardous area digital signal isolation (Zone 0, 1, 2, and Class I Div 1/2).

Technical Specifications

Manufacturer Weidmuller
Part Number / Model 8965370000 (ACT20X-2HDI-2SDO-RNO-S)
Product Type Isolating Switch Amplifier
Number of Channels 2
Input Type NAMUR sensor (DIN EN 60947-5-6) or switch contact
NAMUR Supply 8 V DC / 8 mA
Output Type Relay (1 NO contact per channel)
Nominal Switching Voltage 125 V AC / 110 V DC (safe area)
Continuous Current 0.5 A AC / 0.3 A DC
Supply Voltage 19.2 to 31.2 V DC
Power Consumption ≤ 1.9 W
Configuration FDT/DTM software
Connection Type Screw connection
Protection Degree IP20
Operating Humidity 0 to 95% (no condensation)
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Weight 0.190 kg

Connections and Interfaces

Terminal Pin Function
Inputs (Hazardous Area) Channel 1 & Channel 2 NAMUR / Switch Contacts
Outputs (Safe Area) Channel 1 & Channel 2 Relay NO Contacts
Power Supply 24 V DC (+ / -)
Alarm Output Fault signaling relay contact

Installation Guidelines

  • Mounting: Mount vertically on a standard TS 35 DIN rail.
  • Wiring: Ensure strict physical separation between intrinsically safe (Ex i) input wiring and non-intrinsically safe output/power wiring. Maintain a minimum distance of 50 mm between the terminal groups.
  • Grounding: Connect the DIN rail to the local functional earth ground to ensure proper shielding and noise immunity.
  • Ventilation: Provide adequate clearance above and below the module to prevent heat buildup inside the control cabinet.

Compliance and Certifications

  • CE
  • ATEX
  • IECEx
  • UL Class I, Division 2 / Zone 2
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Weidmuller 8965370000?
It is a 2-channel isolating switch amplifier designed to safely transmit digital signals (such as NAMUR sensors or mechanical contacts) from hazardous Ex zones to safe areas.
How is the ACT20X-2HDI-2SDO-RNO-S configured?
The module is configured using standard FDT/DTM software, allowing precise adjustment of input types, line fault detection, and output behavior.
What type of outputs does this module provide?
It features two normally open (NO) relay outputs, along with an integrated alarm relay for system status and fault signaling.
Does the 8965370000 support line fault detection?
Yes, it includes built-in line fault detection (LFD) to monitor input circuits for short circuits and wire breaks.
Reviews

8965370000

Stock & lead time on request

Call
1 su 1

Weidmuller 8965370000 ACT20X-2HDI-2SDO-RNO-S Isolating Switch Amplifiers

Only 10 item(s) left in stock
  • Manufacturer: Weidmuller

  • Product No.: 8965370000

  • Country of origin:Germany

  • Product Type: Isolating Switch Amplifiers

  • Payment: T/T, Western Union

  • Weight: 190g

  • Dimensions: 117.2 mm x 22.5 mm x 113.6 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Designed for intrinsic safety applications, the Weidmuller 8965370000 functions as a highly reliable isolating switch amplifier to transmit digital signals from hazardous areas (Zone 0, 1, 2) to safe areas. This 2-channel module is engineered to process signals from NAMUR sensors or mechanical contacts located in explosive atmospheres, providing complete galvanic isolation between the input, output, power supply, and alarm contacts.

The ACT20X-2HDI-2SDO-RNO-S features integrated line fault detection (LFD) to monitor the input circuits for wire breaks or short circuits. In the event of a fault, the device triggers an alarm relay, ensuring rapid diagnostics and minimizing system downtime. Configuration is easily managed via standard FDT/DTM software, allowing precise customization of operational parameters to match specific process requirements.

Features

  • Dual-channel signal isolation and transmission from Ex to non-Ex zones.
  • Intrinsically safe input circuits compatible with NAMUR sensors and mechanical switches.
  • Two normally open (NO) relay outputs for reliable signal switching.
  • Comprehensive line fault detection (LFD) for short-circuit and wire-break monitoring.
  • FDT/DTM software configuration for flexible parameter adjustment.
  • Complete galvanic isolation between input, output, power supply, and alarm contacts.
  • Compact 22.5 mm DIN-rail mountable housing to optimize cabinet space.

Applications

  • Chemical and petrochemical processing plants.
  • Oil and gas extraction, refining, and distribution facilities.
  • Water and wastewater treatment automation.
  • Hazardous area digital signal isolation (Zone 0, 1, 2, and Class I Div 1/2).

Technical Specifications

Manufacturer Weidmuller
Part Number / Model 8965370000 (ACT20X-2HDI-2SDO-RNO-S)
Product Type Isolating Switch Amplifier
Number of Channels 2
Input Type NAMUR sensor (DIN EN 60947-5-6) or switch contact
NAMUR Supply 8 V DC / 8 mA
Output Type Relay (1 NO contact per channel)
Nominal Switching Voltage 125 V AC / 110 V DC (safe area)
Continuous Current 0.5 A AC / 0.3 A DC
Supply Voltage 19.2 to 31.2 V DC
Power Consumption ≤ 1.9 W
Configuration FDT/DTM software
Connection Type Screw connection
Protection Degree IP20
Operating Humidity 0 to 95% (no condensation)
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Weight 0.190 kg

Connections and Interfaces

Terminal Pin Function
Inputs (Hazardous Area) Channel 1 & Channel 2 NAMUR / Switch Contacts
Outputs (Safe Area) Channel 1 & Channel 2 Relay NO Contacts
Power Supply 24 V DC (+ / -)
Alarm Output Fault signaling relay contact

Installation Guidelines

  • Mounting: Mount vertically on a standard TS 35 DIN rail.
  • Wiring: Ensure strict physical separation between intrinsically safe (Ex i) input wiring and non-intrinsically safe output/power wiring. Maintain a minimum distance of 50 mm between the terminal groups.
  • Grounding: Connect the DIN rail to the local functional earth ground to ensure proper shielding and noise immunity.
  • Ventilation: Provide adequate clearance above and below the module to prevent heat buildup inside the control cabinet.

Compliance and Certifications

  • CE
  • ATEX
  • IECEx
  • UL Class I, Division 2 / Zone 2

What is the primary function of the Weidmuller 8965370000?

It is a 2-channel isolating switch amplifier designed to safely transmit digital signals (such as NAMUR sensors or mechanical contacts) from hazardous Ex zones to safe areas.

How is the ACT20X-2HDI-2SDO-RNO-S configured?

The module is configured using standard FDT/DTM software, allowing precise adjustment of input types, line fault detection, and output behavior.

What type of outputs does this module provide?

It features two normally open (NO) relay outputs, along with an integrated alarm relay for system status and fault signaling.

Does the 8965370000 support line fault detection?

Yes, it includes built-in line fault detection (LFD) to monitor input circuits for short circuits and wire breaks.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...