Weidmuller

Weidmuller 8965380000 ACT20X ACT20X-2HDI-2SDO-RNC-S Isolating Switch Amplifier

SKU 8965380000

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Weidmuller
  • Product No.: 8965380000
  • Origin Germany
  • Product Type: Isolating Switch Amplifiers
  • Payment: T/T, Western Union
  • Weight: 0.192 kg
  • Dimensions: 119.2 mm x 22.5 mm x 113.6 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Designed for intrinsic safety applications, the **Weidmuller 8965380000** functions as a highly reliable 2-channel **isolating switch amplifier**. This device transmits digital signals from hazardous areas (Zone 0, 1, 2) to safe areas, providing complete galvanic isolation between the input, output, and power supply. It is specifically engineered to interface with NAMUR sensors and mechanical contacts, converting their states into digital relay outputs.

The **ACT20X-2HDI-2SDO-RNC-S** features integrated line fault detection (LFD) capable of identifying line interruptions or short circuits at the input. Diagnostic status and device errors are signaled via an integrated alarm contact, ensuring high system availability and simplified troubleshooting. Configuration is easily performed using standard FDT/DTM software, allowing for precise adjustment of input types, output behavior, and diagnostic parameters.

Features

  • Dual-channel design for space-saving installation on standard DIN rails.
  • Complete 3-way galvanic isolation between input, output, and power supply.
  • Supports both NAMUR sensors and mechanical contact inputs.
  • Integrated line fault detection (LFD) for short-circuit and wire-break monitoring.
  • Dedicated alarm relay output for system diagnostics and error reporting.
  • Simple configuration and parameterization via FDT/DTM software.
  • Secure screw connection terminals for reliable field wiring.

Applications

  • Chemical and petrochemical processing plants.
  • Oil and gas extraction, refining, and distribution.
  • Water and wastewater treatment facilities.
  • Hazardous area signal isolation and safety-instrumented systems.

Technical Specifications

Manufacturer Weidmuller
Part Number / Model 8965380000 / ACT20X-2HDI-2SDO-RNC-S
Product Type Isolating Switch Amplifier
Number of Channels 2
Supply Voltage 19.2 to 31.2 V DC
Power Consumption <= 1.9 W
Input Type NAMUR sensor (DIN EN 60947-5-6), switch contact
NAMUR Supply 8 V DC / 8 mA
Output Type Relay (2 NO contacts)
Nominal Switching Voltage <= 125 V AC / 110 V DC
Continuous Current <= 0.5 A AC / 0.3 A DC
Alarm Function Line interruption at input, short circuit at input, no supply voltage, device error
Configuration FDT/DTM software
Connection Type Screw connection
Protection Degree IP20
Ambient Humidity 0 to 95% (non-condensing)
Operating Temperature -20 to +60 Celsius
Dimensions (H x W x D) 119.2 mm x 22.5 mm x 113.6 mm
Weight 0.192 kg

Connections and Interfaces

Terminal Pin Function
11, 12 Input Channel 1 (Hazardous Area)
13, 14 Input Channel 2 (Hazardous Area)
51, 52 Output Channel 1 Relay (Safe Area)
53, 54 Output Channel 2 Relay (Safe Area)
41, 42 Power Supply (19.2 to 31.2 V DC)
43, 44 Alarm Output Relay

Installation Guidelines

  • Mounting: Install vertically on a standard TS 35 DIN rail. Ensure the module is securely locked into place.
  • Wiring Separation: Maintain strict physical separation (at least 50 mm) between intrinsically safe (blue terminals) and non-intrinsically safe wiring to comply with safety standards.
  • Grounding: Ensure the DIN rail is connected to a low-impedance functional earth ground.
  • Ventilation: Provide sufficient clearance above and below the device to allow natural convection cooling and prevent heat accumulation.

Compliance and Certifications

  • CE
  • ATEX
  • IECEx
  • cULus
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Weidmuller 8965380000?
It is a 2-channel isolating switch amplifier designed to transmit digital signals (such as NAMUR sensors or mechanical contacts) from hazardous areas to safe areas with complete galvanic isolation.
How is the ACT20X-2HDI-2SDO-RNC-S configured?
The module is configured using standard FDT/DTM software, allowing users to customize input types, output behaviors, and line fault detection settings.
What alarm functions are supported by this device?
The device features diagnostics for line interruption at the input, short circuits at the input, loss of supply voltage, and internal device errors.
What is the protection rating and mounting style of this module?
The module has an IP20 protection rating and is designed for standard TS 35 DIN rail mounting.
Reviews

8965380000

Stock &amp; lead time on request

Call
1 su 1

Weidmuller 8965380000 ACT20X ACT20X-2HDI-2SDO-RNC-S Isolating Switch Amplifier

Only 10 item(s) left in stock
  • Manufacturer: Weidmuller

  • Product No.: 8965380000

  • Country of origin:Germany

  • Product Type: Isolating Switch Amplifiers

  • Payment: T/T, Western Union

  • Weight: 192g

  • Dimensions: 119.2 mm x 22.5 mm x 113.6 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Designed for intrinsic safety applications, the **Weidmuller 8965380000** functions as a highly reliable 2-channel **isolating switch amplifier**. This device transmits digital signals from hazardous areas (Zone 0, 1, 2) to safe areas, providing complete galvanic isolation between the input, output, and power supply. It is specifically engineered to interface with NAMUR sensors and mechanical contacts, converting their states into digital relay outputs.

The **ACT20X-2HDI-2SDO-RNC-S** features integrated line fault detection (LFD) capable of identifying line interruptions or short circuits at the input. Diagnostic status and device errors are signaled via an integrated alarm contact, ensuring high system availability and simplified troubleshooting. Configuration is easily performed using standard FDT/DTM software, allowing for precise adjustment of input types, output behavior, and diagnostic parameters.

Features

  • Dual-channel design for space-saving installation on standard DIN rails.
  • Complete 3-way galvanic isolation between input, output, and power supply.
  • Supports both NAMUR sensors and mechanical contact inputs.
  • Integrated line fault detection (LFD) for short-circuit and wire-break monitoring.
  • Dedicated alarm relay output for system diagnostics and error reporting.
  • Simple configuration and parameterization via FDT/DTM software.
  • Secure screw connection terminals for reliable field wiring.

Applications

  • Chemical and petrochemical processing plants.
  • Oil and gas extraction, refining, and distribution.
  • Water and wastewater treatment facilities.
  • Hazardous area signal isolation and safety-instrumented systems.

Technical Specifications

Manufacturer Weidmuller
Part Number / Model 8965380000 / ACT20X-2HDI-2SDO-RNC-S
Product Type Isolating Switch Amplifier
Number of Channels 2
Supply Voltage 19.2 to 31.2 V DC
Power Consumption <= 1.9 W
Input Type NAMUR sensor (DIN EN 60947-5-6), switch contact
NAMUR Supply 8 V DC / 8 mA
Output Type Relay (2 NO contacts)
Nominal Switching Voltage <= 125 V AC / 110 V DC
Continuous Current <= 0.5 A AC / 0.3 A DC
Alarm Function Line interruption at input, short circuit at input, no supply voltage, device error
Configuration FDT/DTM software
Connection Type Screw connection
Protection Degree IP20
Ambient Humidity 0 to 95% (non-condensing)
Operating Temperature -20 to +60 Celsius
Dimensions (H x W x D) 119.2 mm x 22.5 mm x 113.6 mm
Weight 0.192 kg

Connections and Interfaces

Terminal Pin Function
11, 12 Input Channel 1 (Hazardous Area)
13, 14 Input Channel 2 (Hazardous Area)
51, 52 Output Channel 1 Relay (Safe Area)
53, 54 Output Channel 2 Relay (Safe Area)
41, 42 Power Supply (19.2 to 31.2 V DC)
43, 44 Alarm Output Relay

Installation Guidelines

  • Mounting: Install vertically on a standard TS 35 DIN rail. Ensure the module is securely locked into place.
  • Wiring Separation: Maintain strict physical separation (at least 50 mm) between intrinsically safe (blue terminals) and non-intrinsically safe wiring to comply with safety standards.
  • Grounding: Ensure the DIN rail is connected to a low-impedance functional earth ground.
  • Ventilation: Provide sufficient clearance above and below the device to allow natural convection cooling and prevent heat accumulation.

Compliance and Certifications

  • CE
  • ATEX
  • IECEx
  • cULus

What is the primary function of the Weidmuller 8965380000?

It is a 2-channel isolating switch amplifier designed to transmit digital signals (such as NAMUR sensors or mechanical contacts) from hazardous areas to safe areas with complete galvanic isolation.

How is the ACT20X-2HDI-2SDO-RNC-S configured?

The module is configured using standard FDT/DTM software, allowing users to customize input types, output behaviors, and line fault detection settings.

What alarm functions are supported by this device?

The device features diagnostics for line interruption at the input, short circuits at the input, loss of supply voltage, and internal device errors.

What is the protection rating and mounting style of this module?

The module has an IP20 protection rating and is designed for standard TS 35 DIN rail mounting.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...