1 of 3

ABB INNPM12 Symphony Network Processing Module

ABB INNPM12 Symphony Network Processing Module

Only 6 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: INNPM12

  • Country of origin:Switzerland

  • Product Type: Network Processor Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 35 mm x 178 mm x 298 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The INNPM12 functions as a high-speed network processing module within the Symphony Enterprise Management and Control System. This unit establishes and manages communication across the high-speed Control Network, or Cnet, which provides an essential data path among Harmony control units (HCU), human system interfaces (HSI), and external computers. Operating in Plant Loop mode, it acts as a slot-compatible system replacement for legacy INLIM03 Loop Interface Modules and INBIM02 Bus Interface Modules, delivering reliable data transfer and processing capability. Through extensive error checking and message acknowledgment, the board secures high system reliability and availability for mission-critical process control data exchange.

Features

  • Coordinates high-speed communication interfaces, including Cnet-to-Cnet, Cnet-to-HCU, and Cnet-to-computer data pathways.
  • Utilizes comprehensive error checking algorithms and message acknowledgment loops to guarantee accurate transmission of critical industrial process data.
  • Operates natively in Plant Loop mode as a modern functional replacement for legacy INLIM03 and INBIM02 communication hardware.
  • Employs dual-channel local communication rates running a 1 Mbaud Controlway and an 83.3 kbaud Module bus.

Applications

  • Symphony Harmony DCS Networks: Managing primary processing channels and node mapping tasks on central communication racks.
  • Plant Loop Communication Bridges: Upgrading legacy network interfaces to support integrated process control highways.
  • Distributed Computer-to-HCU Routing: Interfacing operator console nodes and management computers with local control hardware.

Technical Specifications

Parameter Value
Manufacturer ABB
Model INNPM12
Product Type Network Processing Module
Memory 512 kbytes ROM, 512 kbytes RAM
Power Requirements +5 VDC at 2 A; 10 W
Controlway Communication Rate 1 Mbaud
Module Bus Communication Rate 83.3 kbaud
Mounting Occupies one slot in a standard module mounting unit
Ambient Temperature 0 to 70 degC (32 to 158 degF)
Relative Humidity 5% to 90% up to 55 degC (131 degF) noncondensing; 5% to 40% above 55 degC (131 degF) noncondensing
Atmospheric Pressure Sea level to 3 km (1.86 mi)
Air Quality Noncorrosive
Estimated Weight 0.45 kg
Estimated Dimensions (W x H x D) 35 mm x 178 mm x 298 mm

 

Installation Guidelines

  • Disconnect all active power supplies connected to the rack housing unit before sliding the module into its designated slot.
  • Ensure the communication module is seated firmly into the motherboard connector pins of the standard module mounting unit.
  • Maintain clean, noncorrosive air ventilation within the cabinet enclosure to prevent chemical degradation of components.
  • Adhere to specified operating limits for temperature and humidity when scaling multi-node networks to prevent thermal overload inside sealed panels.

Compliance and Certifications

  • Canadian Standards Association (CSA): Certified for use as process control equipment in an ordinary (nonhazardous) environment.
  • Factory Mutual (FM): Approved as nonincendive equipment for use in Class I; Division 2; Groups A, B, C, D; hazardous locations.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB INNPM12 Symphony Network Processing Module

What legacy hardware modules can this network processing module replace?

Operating in Plant Loop mode, the device acts as a direct replacement for the older INLIM03 Loop Interface Module and the INBIM02 Bus Interface Module.

What are the internal onboard memory specifications for this device?

The device comes equipped with 512 kbytes of ROM and 512 kbytes of RAM to support local network processing operations.

What are the power requirements needed to operate the communication module?

The module requires a steady input voltage of +5 VDC at 2 A, with a total power consumption of 10 W.

Is the device rated for deployment inside hazardous environmental locations?

Yes, it is Factory Mutual (FM) approved as nonincendive equipment for use in Class I; Division 2; Groups A, B, C, and D hazardous locations.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
Switzerland

Recently Viewed Products

Technical knowledge

OpenVMS Alpha жүйесінде жұмыс істейтін Bailey INFI 90 Symphony HMI-лерін жаңарту

OpenVMS Alpha жүйесінде жұмыс істейтін ескірген Bailey Symphony операторлық станцияларын ауыстыруға арналған практикалық нұсқаулық. Ол Alpha эмуляциясын, OpenVMS x86-ға көшіруді, OPC қайта...

Өнеркәсіптік сенімділік үшін техникалық қызмет көрсету деректері неге маңызды

Техникалық қызмет көрсету деректері жұмыс тапсырыстарын, сенсор сигналдарын, активтердің тарихын, шығындарды және техник мамандардың білімін байланыстырады. Оны дұрыс қолдану жоспарлауды,...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...