1 of 1

Danfoss 132F0024 FC-051P3K0T4E20H3BXCXXXSXXX VLT Micro Drive

Danfoss 132F0024 FC-051P3K0T4E20H3BXCXXXSXXX VLT Micro Drive

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 132F0024

  • Country of origin:United States

  • Product Type: Frequency Converters

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Dimensions: 19.4 cm x 9 cm x 23.9 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The 132F0024 is a versatile FC-051P3K0T4E20H3BXCXXXSXXX VLT Micro Drive engineered for compact and efficient motor speed regulation. As part of the Danfoss VLT Micro Drive series, this unit is designed to provide high-performance control for 3.0 kW (4.0 HP) motors in three-phase industrial applications. It features an IP20-rated chassis and includes a built-in brake chopper and coated PCBs for enhanced durability and operational flexibility.

Features

  • Integrated brake chopper for demanding stopping applications
  • RFI Class A1/B (C1) filter for electromagnetic compatibility
  • Conformal coated PCB for increased protection against environmental factors
  • Flexible control options with 5 programmable digital inputs and 2 analogue inputs
  • Adjustable output frequency up to 400 Hz for various motor control modes
  • Compact form factor for optimized panel space utilization

Applications

  • Material handling and conveyor systems
  • Centrifugal pumps and fan control
  • Industrial mixing and stirring equipment
  • Small-scale industrial machinery and processing lines

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Number 132F0024
Model FC-051P3K0T4E20H3BXCXXXSXXX
Product Group VLT Micro Drive FC 51
Power Rating 3.0 kW / 4.0 HP
Input Voltage 380-480 VAC (Three Phase)
Output Frequency 0-200 Hz (VVC+), 0-400 Hz (U/f)
Enclosure IP20 / Chassis
RFI Filter Class A1/B (C1)
Digital Inputs 5 (0-24 VDC)
Analogue Inputs 2
Dimensions (L x W x H) 19.4 cm x 9 cm x 23.9 cm
Shipping Weight 5 Kg

Installation Guidelines

  • Mounting: Secure the drive vertically on a flat, stable surface to maintain thermal efficiency and proper heat sink ventilation.
  • Cooling: Ensure unobstructed airflow around the unit. Follow the manufacturer's recommended clearance distances to prevent thermal shutdown.
  • Wiring: Keep control and power cabling segregated to avoid electromagnetic interference. Use shielded cables for all signal lines.
  • Grounding: Always connect the chassis ground to the system protective earth for safety and to satisfy RFI mitigation requirements.
  • Environmental: Ensure the installation site is protected from excessive dust, moisture, and corrosive substances.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...