1 of 3

Emerson PR6426/000-131 CON041/916-200 Eddy Current Sensor System

Emerson PR6426/000-131 CON041/916-200 Eddy Current Sensor System

Only 6 item(s) left in stock
  • Manufacturer: Emerson

  • Product No.: PR6426/000-131 CON041/916-200

  • Country of origin:United States

  • Product Type: Eddy Current Sensor

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 960g

  • Dimensions: 4.1cm x 15.9cm x 10.8cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Emerson PR6426/000-131 non-contact eddy current sensor operates in combination with the CON041/916-200 signal converter to form a proximity measurement system for heavy industrial turbomachinery. Engineered for deployment on steam, gas, and hydro turbines, as well as compressors, pumps, and fans, this assembly measures radial and axial shaft displacement, position, eccentricity, and motion. The PR6426/000-131 sensor monitors physical shaft proximity without direct contact, while the CON041/916-200 converter processes these variables into normalized electrical outputs suitable for continuous machinery protection networks.

Features

  • Non-contact eddy current measurement mechanism for detailed shaft dynamics and displacement tracking 
  • High-pressure durability with a sensor head rated to withstand up to 6,500 hpa 
  • Extended measurement range up to 20.0mm when paired with the designated configuration converter 
  • Rugged physical construction featuring a stainless steel sleeve and high-temperature PTFE cable insulation 
  • Fast loop processing execution defined by a signal rise time under 15 microseconds 

Applications

  • Radial and axial shaft dynamic displacement logging 
  • Industrial turbomachinery position, motion, and eccentricity monitoring 
  • Machinery protection monitoring across turbines, compressors, and large industrial fans 

Ordering Information

Model Number Sensor Type Measuring Range Linearity Error
CON041/916-200 PR6426 20.0mm (Extended Range) <= 2.5% 

Technical Specifications

Dynamic & Performance Specifications

Parameter Specification
Frequency Range (-3 dB) 0 to 20,000 Hz 
Rise Time <15 us 
Sensor Sensitivity 2 V/mm (50.8 mV/mil) <= +/-1.5% max 
Air Gap (Center) Approx. 5.5 mm (0.22") Nominal 
Long Term Drift <0.3% 
Maximum Surface Speed 2,500 m/s (98,425 ips) 
Target / Surface Material Ferromagnetic Steel (42 Cr Mo 4 Standard) 
Target Shaft Diameter >= 200 mm (7.87") 

Electrical & Power Specifications

Parameter Specification
Supply Voltage Range (-24V Configuration) -23V to -32V (Output Range: -4V to -20V) 
Supply Voltage Range (-2V Configuration) -21V to -32V (Output Range: -2V to -18V) 

Environmental Specifications

Parameter Specification
Converter Operating Temperature Range -30 to 100 degC (-22 to 212 Fahrenheit) 
Sensor Operating Temperature Range -35 to 175 degC (-31 to 347 Fahrenheit) 
Sensor Temperature Excursions (<4 Hours) 200 degC (392 Fahrenheit) 
Maximum Cable Temperature 200 degC (392 Fahrenheit) 
Converter Shock and Vibration 5g @ 60Hz @ 25 degC (77 Fahrenheit) 
Sensor Shock and Vibration 5g (49.05 m/s2) @ 60Hz @ 25 degC (77 Fahrenheit) 
Converter Protection Class IP20 

Physical Specifications

Parameter Specification
Manufacturer Emerson 
Converter Housing Material PA 6.6 
Converter Weight ~60 grams (2.12 oz) 
Sensor Sleeve Material Stainless Steel 
Sensor Cable Material PTFE 
Sensor Weight (with 1M Cable, No Armor) ~800 grams (28.22 oz) 

Connections/Interfaces

Connector / Terminal Function
Transducer Input Connection Self-Locking Lemo-Plug 
Supply / Output Connection Screw Terminal Type (Max. 1.5mm2, wire-end sleeves) 

Installation Guidelines

  • Install the signal converter module on a standard DIN rail carrier inside the enclosure.
  • Maintain a clear zone of at least 80 mm diameter free of ferrous material around the 32mm sensor head to avoid field distortion.
  • Observe a minimum cable bending radius of 35 mm for armored cable paths, or 25 mm for non-armored variants.
  • Calibrate the initial sensor position to a nominal center air gap of approximately 5.5 mm.

Compliance and Certifications

  • CE: 2014/30/EU (EN 61326-1), 2014/34/EU, 2011/65/EU (DIN EN 50581) 
  • ATEX: EN 60079-0, EN 60079-11; II 2 G Ex ia IIC T4 Gb (-20 degC <= Ta <= 80 degC) 
  • IEC-Ex: IEC 60079-0, IEC 60079-11, IEC 60079-26; Ex ia IIC T4 Gb (-20 degC <= Ta <= 80 degC) 
  • CSA: CAN/CSA-C22.2 NO. 0-M91, NO. 157-92, NO. 213-M1987, CAN/CSA-E60079-15-02, NO. 25-1966, NO. 61010-1-04; ANSI/UL Standard 913-2004, ANSI/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1 
  • Hazardous Area Entry: Intrinsic Safety (Ex ia IIC T4 Gb / Class I Division 1 Groups A, B, C, D T4); Non-sparking (Class I Division 2 Groups A, B, C, D / Ex nA II T3..T4 / AEx nA II T3..T4) 

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson PR6426/000-131 CON041/916-200 Eddy Current Sensor System

What is the maximum linear measuring range achievable with this specific sensor system combination?

When the 32mm sensor is paired with this specific converter configuration, it provides an extended linear measurement range of 20.0mm.

What is the minimum bending radius allowed for the sensor cable during installation?

The minimum allowed static bending radius is 35 mm for armored cable options and 25 mm for non-armored configurations.

What are the ambient temperature parameters certified under the intrinsic safety classifications?

For ATEX and IEC-Ex intrinsic safety zones, the device is certified for operation within an ambient temperature range of -20 degC to 80 degC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...