1 of 1

Honeywell TK-CCR014 C200 Redundant ControlNet Interface Module

Honeywell TK-CCR014 C200 Redundant ControlNet Interface Module

Only 4 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TK-CCR014

  • Country of origin:United States

  • Product Type: Fieldbus Communication Modules

  • Payment: T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The TK-CCR014 is a high-reliability communication routing component operating as a Redundant Net Interface Module within the Honeywell C200 and Experion distributed control system (DCS) architectures. This interface module provides critical dual-channel ControlNet network linking capabilities, acting as the deterministic communication bridge between primary processing chassis networks and remote I/O chassis blocks. Built with a redundant network transceiver layout, the unit monitors connection path health in real time and automatically executes sub-millisecond switchovers to the backup channel if a media interruption occurs. This fault-tolerant structure guarantees steady parameters, safety logic execution, and uninterrupted diagnostic telemetry across centralized process networks.

Features

  • Redundant dual-channel interface supporting seamless network media switchovers.
  • Highly deterministic ControlNet protocol management for real-time tracking.
  • Standardized form factor for direct rack integration into standard C200 slots.
  • Integrated front-panel status lights for instant diagnostic and link health reporting.

Applications

  • Redundant network tracking between master C200 processors and remote I/O racks.
  • High-availability communication bridging in distributed control systems (DCS).
  • Supervisory network isolation in chemical manufacturing and petroleum refineries.
  • Real-time network infrastructure coordination inside critical power generation utility loops.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model TK-CCR014
Product Type Redundant Net Interface Module (ControlNet FIM)
Product Series C200 / Experion System Chassis I/O (CIOM-A)
Weight 0.45 Kg
Shipping Weight 2 Kg
Country of Origin United States / Global Operations
Network Protocol ControlNet (Redundant Media Support)

Installation Guidelines

Grounding and Shielding

Verify that the hosting C200 equipment rack is bonded cleanly to the main facility instrument grounding network using a low-impedance copper wire. Communication trunk coax and tap cables must follow standardized network installation procedures, ensuring that the shield integrity is maintained across the segments to suppress high-frequency radio interference.

Handling and ESD Protection

The internal communication processors are highly sensitive to electrostatic discharge (ESD). Field engineers must wear an approved, snug-fitting static-dissipative wrist strap connected to a verified ground prior to unboxing the module, shifting node addresses, or sliding the card into the chassis backplane.

Alignment and Insertion

Align the edges of the module's circuit board with the molded plastic track guides of the local slot. Slide the unit inward firmly until the rear pins match and fully engage the backplane connector. Secure the mechanical faceplate screws to protect the communication interface from continuous industrial panel vibration.

Network Cable Routing

Maintain a safe physical clearance between the network coax cables and high-voltage AC mains lines or heavy motor starters. Keeping the network lines inside dedicated, isolated conduit trays minimizes magnetic fields from introducing data errors or transmission delays on the control link.

FAQ

What is the core purpose of this interface module?

It provides a redundant, deterministic ControlNet link to connect process controllers with distributed remote I/O chassis assemblies.

How does the module react if one of the network cables is broken?

The internal redundant interface immediately switches data traffic to the secondary channel without dropping communication frames or resetting the rack status.

Is this device compatible with standard Honeywell C200 systems?

Yes, it utilizes the precise physical form factor required to fit into standard CIOM-A rack slots.

What is the net unboxed weight of this communication hardware?

The standalone unboxed module has an exact physical weight of 0.45 Kg.

What do the front-panel indicator lights signify?

The LEDs provide real-time status diagnostics regarding module health, backplane synchronization, and the operational link state of both channels.

Does this hardware require distinct configuration settings?

Yes, hardware node switches or software configuration tools must be set to assign the module its correct address on the network.

What type of cabling is used to hook up this network module?

It connects to standard industrial ControlNet network layouts using coaxial media taps and BNC-style locking terminators.

Can this component run as an independent loop controller?

No, it is a dedicated network communications interface designed to route data packages between controllers and peripheral racks.

What precautions should be followed concerning static discharge during card replacement?

Always practice correct ESD guidelines, utilizing grounded bags and active wrist straps whenever handling the module out of the chassis.

What is the total package mass when packed for standard freight delivery?

The gross shipping weight of the module and its protective industrial box is specified at 2 Kg.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...