1 of 1

Schneider Altistart 1 ATS01N212LU Soft Starters

Schneider Altistart 1 ATS01N212LU Soft Starters

Only 7 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATS01N212LU

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 530g

  • Dimensions: 17,5cm x 15,2cm x 5,5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ATS01N212LU is an Altistart 01 soft starter engineered to provide smooth starting for asynchronous motors in various industrial applications. Designed for a current rating of 12 A, this unit operates within a supply voltage range of 200-240V and is suitable for motor power ratings between 2.2 kW and 3 kW. By controlling the torque and voltage supplied to the motor, the ATS01N212LU reduces mechanical stress during start-up, helping to extend the lifespan of mechanical components and minimize current surges on the electrical network.

Features

  • Optimized for 12 A asynchronous motor control.
  • Supports motor power ratings from 2.2 kW to 3 kW.
  • Wide voltage input range of 200-240V.
  • Compact design for space-constrained industrial panels.
  • Provides smooth acceleration and deceleration to reduce mechanical wear.

Applications

  • Conveyor systems and material handling equipment.
  • Small fan and blower control.
  • Centrifugal and hydraulic pumps.
  • Machines requiring controlled torque ramp-up.

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altistart
Subrange 1
Product Type Soft starters
Rated Current 12 A
Supply Voltage 200-240V
Power Rating 2.2-3 kW
Dimensions 17.5 x 15.2 x 5.5 cm
Weight 0.53 kg
Product Phase Active
Commodity Code 84798997

Installation Guidelines

  • Mounting: The device should be installed vertically on a DIN rail or panel to ensure proper heat dissipation.
  • Ventilation: Maintain sufficient space around the unit to allow for natural airflow, as efficient cooling is required during operation.
  • Wiring: Connect the power supply and motor cables according to the provided wiring diagram, ensuring all terminals are tightened to the specified torque.
  • Protection: It is recommended to install appropriate circuit protection (fuses or circuit breakers) upstream to protect the soft starter and motor from short circuits.
  • Environment: Ensure the installation environment is free from excessive dust, moisture, and corrosive gases to maintain long-term reliability.

What is the rated current for the ATS01N212LU?

The rated current for this soft starter is 12 A.

What power range does this soft starter support?

The ATS01N212LU supports motor power ratings ranging from 2.2 kW to 3 kW.

Is this product still in active production?

Yes, the product status for the ATS01N212LU is currently listed as Active.

What is the primary function of this soft starter?

The device provides a controlled start and stop for asynchronous motors to reduce mechanical shock and electrical current spikes.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...