The 6GT2001-0EA10 is a MOBY I SLG 40 Read/Write Device designed for high-performance industrial RFID identification tasks. This unit features a detached M30 x 57 antenna, providing flexibility for integration in confined mounting spaces. The 6GT2001-0EA10 offers an IP65 degree of protection, ensuring durability in harsh industrial environments, and operates effectively across a wide temperature range of -25 degC to +70 degC. With a maximum limit distance of 70 mm (depending on the specific MDS transponder used), this device is optimized for reliable data exchange in automated tracking and logistics applications.

Features

  • SLG 40 model with a compact, detached M30 x 57 antenna for versatile installation.
  • Robust IP65-rated housing suitable for demanding industrial conditions.
  • Operates in an ambient temperature range from -25 degC to +70 degC.
  • High-reliability data communication for MOBY I RFID systems.
  • Max limit distance of 70 mm (varies by MDS transponder type).

Applications

  • Automated assembly lines and manufacturing tracking.
  • Warehouse management and logistics identification.
  • Material flow control in production environments.
  • Tool and workpiece identification in machining centers.

Technical Specifications

Parameter Specification
Manufacturer Siemens
Brand MOBY
Range I
Product Type Read/Write Device
Model SLG 40
Antenna Detached M30 x 57
Degree of Protection IP65
Temperature Range -25 degC to +70 degC
Max. Limit Distance 70 mm (transponder dependent)
Dimensions 12.50 cm x 4.00 cm x 7.50 cm (Device)
Weight 0.40 kg
Commodity Code 84719000

Installation Guidelines

  • Mounting: Ensure the detached antenna is securely mounted using the provided M30 threading. Avoid installation in close proximity to large metal surfaces if possible to prevent signal attenuation.
  • Environmental Exposure: While the unit is IP65 rated, ensure cable connections are sealed and protected from direct chemical washdowns or extreme moisture.
  • Signal Interference: Keep the read/write field clear of metallic objects and other high-frequency noise sources to maintain the maximum 70 mm operating distance.
  • Wiring: Use appropriate interface cabling to connect the SLG 40 to the respective RFID controller, ensuring correct shielding to minimize EMI.

What is the maximum read distance of the 6GT2001-0EA10?

The maximum limit distance is 70 mm, though this value depends on the specific MDS transponder used.

Does this device include the antenna?

Yes, it is supplied with a detached M30 x 57 antenna.

What is the IP rating for this RFID reader?

The device features an IP65 degree of protection, making it suitable for industrial environments.

What is the operating temperature range for this module?

The module is designed to operate in temperatures ranging from -25 degC to +70 degC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...