1 daripada 1

ABB ACS580-01-026A-4 ACS580 Variable Frequency Drive

ABB ACS580-01-026A-4 ACS580 Variable Frequency Drive

Hanya 5 item tinggal dalam stok
  • Pengilang: ABB

  • No. Produk: ACS580-01-026A-4

  • Negara asal:Sweden

  • Jenis Produk: Variable Frequency Drives

  • Kod Bar: 85371091

  • Pembayaran: T/T, Western Union

  • Berat: 6800g

  • Dimensi: 373 x 125 x 223 mm (Height x Width x Depth)

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Optimized for reliable and efficient motor control in demanding environments, the ABB ACS580-01-026A-4 is an all-compatible, wall-mounted variable frequency drive tailored for variable torque and constant torque applications. Delivering 11 kW (15 HP) of nominal power at 3-phase 400V, this unit optimizes energy consumption while offering effortless system integration. Part of the ACS580 series, it incorporates an integrated control unit, a built-in harmonic choke, and an EMC filter as standard, minimizing external component requirements in standard cabinet configurations.

Key Features

  • Integrated safe torque off (STO) safety function certified to SIL 3 / PL e standards.
  • Built-in C2 category EMC filter and patented switching choke technology to mitigate harmonic distortion.
  • Supports scalar, vector, and permanent magnet motor control modes for highly adaptable process performance.
  • User-friendly assistant control panel equipped with an intuitive interface and micro-USB connectivity.
  • Robust IP21 enclosure rating for standard wall-mounting layout configurations.

Applications

  • Centrifugal pumps, booster systems, and water treatment operations.
  • Industrial ventilation fans, exhaust systems, and air handling systems.
  • Conveyors, packaging lines, and production material handling machinery.
  • Screw compressors and mixers requiring highly regulated motor speed adjustments.

Technical Specifications

Parameter Specification Values
Manufacturer ABB
Model Code ACS580-01-026A-4
Frame Size R2
Nominal Output Current (I_N) 26.0 A
Light Overload Current (I_Ld) 25.0 A
Heavy Duty Current (I_Hd) 17.0 A
Nominal Power (P_N) 11.0 kW (15.0 HP)
Main Input Voltage Range 3-phase 380 to 480 VAC (+10% / -15%)
Enclosure Class IP21 / UL Type 1
Operating Temperature Range -15 to 50 degC (derating applicable above 40 degC)
Analog Inputs 2 x Programmable (voltage or current configuration)
Analog Outputs 2 x Programmable (0 to 20 mA range)
Digital Inputs 6 x Programmable (24 VDC internal/external logic support)
Relay Outputs 3 x Programmable (Form C, 250 VAC / 30 VDC, 2 A max)
Embedded Fieldbus Connection Modbus RTU (EIA-485 interface)
Shipping Weight (Calculated) 6.80 kg (15.0 lbs)
Package Dimensions (Calculated) 373 x 125 x 223 mm (Height x Width x Depth)

Control Connections & Interfaces

Terminal Block Default Signal Assignment Electrical Characteristics
+24V / DGND Auxiliary Voltage Output 24 VDC, max. 250 mA current supply
DI1 Start / Stop Command Digital input, PNP/NPN selection (12 to 30 VDC)
DI2 Forward / Reverse Rotation Digital input, PNP/NPN selection (12 to 30 VDC)
AI1 External Speed Reference Analog input: 0 to 10 V, or 0/4 to 20 mA
OUT1, OUT2, OUT3 Relay Outputs 1 to 3 Changeover contacts, resistive rating 2 A at 250 VAC
OUT4, OUT5 (STO) Safe Torque Off (Dual Channel) SIL 3 compliance, physical safety loop inputs

Empirical Engineering Insights

Alternative Models & Compatibility

The ACS580-01-026A-4 serves as a highly robust replacement pathway for discontinued legacy ACS550-01-023A-4 installations. While it offers identical mounting footprint configurations for standard Frame R2 environments, always verify that external parameter maps (especially those associated with dynamic braking parameters or custom macro configurations) are converted using Drive Composer software prior to field execution.

Application Pitfalls & Engineering Notes

Operating the Frame R2 chassis at environmental ambient temperatures exceeding 40 degC will invoke a linear current derating of 1% per additional 1 degC up to a absolute threshold of 50 degC. To avoid unexpected thermal-related under-voltage or over-current tripping under heavy-duty duty cycles (e.g., loaded conveyors), ensure the ventilation pathways match standard factory clear-space specifications of 150 mm top and bottom clearance.

Commissioning & Wiring Tips

Do not run control cable wires adjacent to high-voltage motor output lines. Always establish 360-degree shielding grounding contacts on all incoming control shield cables directly at the metallic drive gland plate. When using external 24 VDC options, confirm that correct jumper routing has been executed on the control board terminals to prevent ground-loop signal variations.

Installation Guidelines

CRITICAL WARNING: Verify that the main AC power distribution feeding the drive is completely de-energized and locked out. Allow a minimum of 5 minutes after switching off the power input supply to allow the internal DC bus capacitors to fully discharge. Always use an approved digital multimeter to measure DC link terminal voltage (UDC+ to UDC-) to verify the system is at 0V prior to wiring.
1

Mount the R2 frame unit vertically on a flat, non-flammable backplate using standard M5 fastening screws to secure the top and bottom structural tabs.

2

Route the symmetric 3-phase incoming power lines to the input terminals U1, V1, and W1, and ground the incoming PE line to the cabinet chassis ground block.

3

Connect the symmetrical shielded motor cable strictly to terminals U2, V2, and W2. Ensure the copper shield of the motor cable is terminated with a 360-degree clamp at the drive ground bracket.

4

Verify that the Safe Torque Off (STO) jumper wires are properly terminated in terminals OUT4/OUT5 unless external physical dual-channel emergency stop safety relays are connected.

Loading product navigation…

What is the standard frame size for the ACS580-01-026A-4 drive?

This model belongs to the Frame R2 class of wall-mounted variable frequency drives.

Does this drive include a built-in harmonic mitigation component?

Yes, it is equipped with a built-in choke and an integrated EMC C2 category filter as standard equipment.

What are the safe torque off (STO) specifications for this drive?

It features integrated dual-channel Safe Torque Off (STO) terminals designed to meet SIL 3 (EN/IEC 61508) and PL e (EN ISO 13849-1) safety standards.

Is derating required for high operating temperatures?

Yes. No current derating is required for ambient temperatures up to 40 degC. Between 40 degC and 50 degC, output current must be derated by 1% per additional degC.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...