  • Manufacturer: Allen-Bradley

  • Product No.: 1794-ADN

  • Country of origin:Amerika Syarikat

  • Product Type: DeviceNet Adaptor

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 195g

  • Dimensions: 87 mm x 68 mm x 69 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The 1794-ADN is a network communications adapter designed for the FLEX I/O distributed input/output platform. This component serves as the physical and logical gateway linking a local cluster of up to eight digital, analog, or specialty operational modules to a centralized programmable logic controller over a DeviceNet network infrastructure. It manages high-speed, bidirectional data transactions, translating the subsystem bus variables across the proprietary FlexBus backplane into discrete application-layer frames specified by the open industrial network standard.

Operating as a standard slave device on the master bus, the module contains built-in microcontrollers that manage independent startup mapping routines, including a fresh out-of-the-box discovery protocol that auto-detects and allocates precise block dimensions per physical I/O slot. The integrated communication hardware accommodates a singular drop or daisy-chain linear topology using screw-secured plug-in connectors. The 1794-ADN is deployed inside industrial machine panels, remote sensor arrays, assembly plant conveyor lines, and localized processing skids requiring reliable, space-saving signal multiplexing to reduce physical panel wiring overhead.

Features

  • Interfaces a centralized DeviceNet infrastructure with local modular distributed FLEX I/O rails.
  • Automatic physical I/O slot discovery and configuration parsing during power-up sequence routines.
  • Removable front-mounted network screw connector to maintain cable bus connections during replacement cycles.
  • Three physical rotary thumbwheel selectors enabling immediate, hard-wired node address specification.
  • Direct internal translation capabilities for up to eight distinct operational backplane modules.
  • Three distinct diagnostic light-emitting diodes providing localized status logs for power, adapter, and network link states.

Applications

  • Distributed control panel sensor aggregation over wide production plant networks.
  • Automotive assembly station line monitoring and discrete block control.
  • Conveyor sortation systems and high-density packaging line distribution clusters.
  • Specialized manufacturing skid machinery data acquisition.

Technical Specifications

Parameter Specification
Manufacturer Rockwell Automation / Allen-Bradley
Brand FLEX I/O
Part Number 1794-ADN
Module Type DeviceNet Communications Adapter
I/O Module Capacity 8 Modules Maximum
Supported Protocols DeviceNet
Network Baud Rates 125 kbps, 250 kbps, 500 kbps
Input Supply Voltage 24V DC Nominal
Operational Voltage Window 19.2V DC to 31.2V DC (Includes 5% AC Ripple)
Supply Current Draw 300 mA at 24V DC, 400 mA at 19.2V DC Maximum
DeviceNet Network Power Load 24V DC at 90 mA Maximum
FlexBus Power Delivery 640 mA at 5V DC Maximum
Isolation Voltage 50V Continuous (Basic Insulation Type)
Power Dissipation 7.6 W Maximum at 19.2V DC
Thermal Dissipation 26 BTU/hour Maximum at 19.2V DC
Enclosure Type Rating Open Style / IP20
Wire Size Limits 22 AWG to 12 AWG Stranded Copper Rated at 75 Celsius Minimum
Operating Temperature 0 to 55 degC
Storage Temperature -40 to 85 degC
Relative Humidity Window 5% to 95% Non-Condensing
Country of Origin USA
Weight 195.5 g
Dimensions 87 mm x 68 mm x 69 mm

Connections/Interfaces

Connector Pin Function
Terminal A External Operational Supply +V DC Input
Terminal B External Operational Supply -V Common Input
Terminal C Chassis Functional Earth Ground Lead Connection
DeviceNet Pin 1 (Black) Network V- Power Supply Reference Common
DeviceNet Pin 2 (Blue) CAN_L Signal Communication Inverted Node
DeviceNet Pin 3 (Bare) Network Cable Metallic Drain Shield Ground Node
DeviceNet Pin 4 (White) CAN_H Signal Communication Non-Inverted Node
DeviceNet Pin 5 (Red) Network V+ External Operating Power Rail

Installation Guidelines

DIN Rail Mounting

Tilt the top lip of the adapter bracket assembly onto an IEC-compliant 35 mm metallic DIN rail. Pivot the lower half of the module box downward until the spring-activated bottom tracking latch engages into a locked alignment. Install rigid physical end anchors flanking the boundary ends of the rail string to block lateral movement.

FlexBus Backplane Alignment

Position the network adapter module at the leftmost boundary slot of the mounting rail. Align the receiving notch profile on the lower right casing wall with the anchor hook on the first functional I/O terminal base, sliding the units firmly together until the side FlexBus connection bus path pins bridge fully inside the terminal sockets.

Wiring and Torque Requirements

Exclusively terminate field cables using stranded copper conductors inside specified gauge restrictions. Torque all front removable terminal block power connections to exactly 0.8 N-m (7 lb-in). Ensure power supply connection leads tracking the external direct current input are brief and do not exceed 3 meters in total length.

Noise Separation Regulations

Isolate network interface drop lines and associated FlexBus signaling rails away from electrical power drops, variable frequency drive output conduits, high-voltage switching fields, and heavy motor feeds to prevent high-frequency electromagnetic field induction.

FAQ

What is the maximum number of modules this adapter can drive?

The unit can interface with up to eight independent FLEX I/O modular blocks attached continuously to the right side of its backplane.

How is the unique network address defined on this specific component?

The node address is selected manually by adjusting the three mechanical rotary thumbwheel switches on the front facing panel before starting the network.

What power output does the internal circuit feed down the local backplane?

The adapter supplies a maximum current of 640 mA at 5V DC to power the logic chips of connected extension modules.

Does this device require power from both the external source and the network cable?

Yes, the internal backplane requires a standard 24V DC auxiliary source, while the primary transceiver circuit must receive power directly from the active DeviceNet trunk lines.

What do flashing red cycles on the Module/Network LED signify?

A flashing red indication represents a minor recoverable fault state, suggesting an address configuration conflict or a data register mismatch.

What is the maximum data rate supported across this link?

The adapter communicates at standard industrial intervals of 125 kbps, 250 kbps, and 500 kbps depending on total network loop lengths.

Can an engineer hot-swap the network adapter when the system is active?

No, while individual I/O modules allow removal under power, extracting the network adapter completely interrupts communication blocks for all eight secondary points.

What isolation rating is certified for this specific interface structure?

The unit features basic insulation certified for a continuous potential barrier up to 50V between user power lines and the system logic circuitry.

What setting initiates an absolute factory configuration wipe on the hardware?

Setting the three mechanical rotary switch dials to a code pattern of 888 and cycling power executes an internal memory clear routine.

What type of cabling is approved to bridge the primary bus connections?

The network link requires certified Belden YR-29832 or equivalent shielded industrial twisted-pair DeviceNet media.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Putih Kelabu
Country of origin
Amerika Syarikat
Power source
Kuasa DC

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...