1 of 1

B&R X20AO2632 X20 Analog Output Module

B&R X20AO2632 X20 Analog Output Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20AO2632

  • Country of origin:Amerika Syarikat

  • Product Type: X20 analog output module

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Signal Processing and System Synchronization

The X20AO2632 (X20 AO 2632) is a high-precision, dual-channel analog output module developed for the B&R X20 System architecture. Designed for process critical applications including turbine governor control, proportional valve positioning, and high-speed servo drive velocity referencing, this module provides highly accurate control signal generation.

By incorporating a high-speed digital-to-analog converter (DAC) that operates with a 16-bit resolution, the X20AO2632 delivers a stable output range of either $\pm$10 V or 0 to 20 mA. Signal conversion takes just 50 $\mu$s for all channels simultaneously. This rapid conversion execution combined with the integrated NetTime hardware synchronization protocol makes the module perfect for tight, deterministic closed-loop architectures where minimal processing jitter and strict temporal alignment are required to maintain process stability.

Output Configuration and Hardware Safety

The physical interface provides the flexible distribution of voltage and current signals via independent, dedicated terminal connections. For voltage configurations, the conversion resolution is established at $\pm$15-bit, while current configurations utilize a native 15-bit data structure.

To prevent erratic machine behavior during system initialization, the module is equipped with an internal electronic enable relay. This relay physically disconnects the output circuitry from external field devices during the controller boot sequence, ensuring that uncalibrated or transient voltages do not reach connected actuators before the central application achieves a stable running state.

Technical Performance Data

Engineering Metric Parameter Value
Model X20AO2632
Brand B&R (Automation)
Origin Austria
Module Configuration 2 Analog Outputs ($\pm$10 V or 0 to 20 mA)
Converter Resolution Voltage: $\pm$15-bit / Current: 15-bit (16-bit native)
Conversion Time Rate 50 $\mu$s for all outputs simultaneously
Settling Time Bounds 500 $\mu$s over full range (Revision H0 and higher) / 1 ms (Prior to Rev. H0)
Boot Protection Mechanics Internal electrical enable relay for controlled power-up
Bus Power Consumption 0.01 W
Internal I/O Power Draw 1.1 W
Shipping Weight 2.0 kg

Field Operations and Support FAQs

How do the different revisions of the module affect system response time?

Hardware revision codes older than H0 require a 1 ms settling time across the entire signal range. Revision H0 and later incorporate upgraded internal electronics that halve this value to 500 $\mu$s. If your process requires high-frequency adjustments, ensure your physical spare parts inventory matches the updated revision status.

How does the internal enable relay manage safety during a system crash?

The internal enable relay is coupled directly to the module's watchdog and communication monitoring circuits. If the central PLC goes offline or backplane communication is lost, the relay immediately opens. This drops the field outputs to an unpowered state rather than holding a potentially dangerous stale analog value.

What elements make up the listed 2.0 kg shipping weight?

The 2.0 kg shipping specification represents the complete heavy-duty logistical packaging setup. The module is shipped enclosed in thick anti-static shielding film, placed inside custom high-density molded shock-insulation cavities, and boxed with structural cardboard inserts to safeguard the delicate analog components against severe physical vibration during transit.


Field Commissioning and Engineering Wiring Rules

  • Dedicated Terminal Selection for Signal Types: The module handles voltage ($\pm$10 V) and current (0 to 20 mA) outputs through distinct terminal connection pins. Verify your field device electrical requirements and map the signal wires precisely to the designated terminals. Connecting a low-impedance current loop to a voltage terminal configuration can result in internal component stress.

  • Analog Shielding and Ground Loop Prevention: Use high-quality twisted-pair shielded instrumentation cable for all analog output signal paths. Terminate the shield braid exclusively at one end—preferably at the control enclosure's single-point grounding rail—using a low-impedance clamp. Grounding both ends can create ground loops that introduce electrical noise into the 16-bit analog signals.

  • Thermal Settlement and Airflow Clearances: Maintain standard vertical alignment on the DIN rail with at least 30 mm of free space above and below the module assembly. Proper ventilation ensures the internal DAC components operate within stable thermal margins, preventing thermal drift from compromising signal accuracy across continuous duty cycles.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Putih Kelabu
Country of origin
Amerika Syarikat

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...