1 daripada 1

BECKHOFF BK3110 PROFIBUS Bus Coupler

BECKHOFF BK3110 PROFIBUS Bus Coupler

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: BK3110

  • Negara asal:Jerman

  • Jenis Produk: PROFIBUS Bus Couplers

  • Pembayaran: T/T, Western Union

  • Berat: 150g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed to integrate decentralized fieldbus networks with modular I/O hardware, the BECKHOFF BK3110 is a high-performance PROFIBUS Bus Coupler that links Beckhoff Bus Terminals to PROFIBUS DP and DPV1 protocols. Operating as a decentralized station, this coupler provides modular system expansion, managing up to 64 individual Bus Terminals and supporting a maximum of 256 digital inputs and outputs on a single bus node.

The BK3110 functions as a gateway, translating the physical transfer technology of the PROFIBUS DP network to the internal, terminal-specific K-bus. This ensures clean, low-latency communication with the host PLC or DCS. High-speed transmission rates up to 12 Mbaud are supported, providing rapid update times for highly time-critical industrial processes. Configuration is completed dynamically via the higher-level master controller or locally utilizing the KS2000 configuration software interface.

Features

  • Full protocol compatibility with standard PROFIBUS DP and DPV1 fieldbus architectures.
  • Robust local K-bus master capability managing up to 64 modular Bus Terminals.
  • Supports high-speed serial fieldbus transmission with baud rates up to 12 Mbaud.
  • Integrated D-sub 9-pin female connector interface for reliable physical layer bus connection.
  • Direct integration with KS2000 configuration software for easy startup, offline diagnostic evaluation, and commissioning.
  • Compact IP20 enclosure designed for space-optimized installation on standard 35 mm DIN rails.
  • Internal galvanic isolation rated at 500 Veff protecting the control electronics from power supply and fieldbus disturbances.

Applications

  • Automotive assembly and automated welding lines.
  • Wastewater treatment facilities and municipal pumping stations.
  • Packaging, sorting, and material handling systems.
  • Power generation and auxiliary power distribution controls.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model BK3110
Protocol Support PROFIBUS DP, DPV1
Baud Rate Range Up to 12 Mbaud
Bus Connection D-sub 9-pin socket
Max. Number of Bus Terminals 64
I/O Signal Capacity 256 digital inputs/outputs (32 bytes input / 32 bytes output)
Supply Voltage 24 V DC (-15% / +20%)
Input Current 80 mA + (total K-bus current / 4), max. 200 mA
Power-on Surge Current 2.5 x steady operating current
K-bus Supply Current Max. 500 mA
Power Contact Voltage Max. 24 V DC / AC
Power Contact Current Capacity Max. 10 A
Dielectric Strength 500 Veff (power contact / supply voltage / fieldbus)
Operating Temperature 0 degC to +55 degC
Storage Temperature -20 degC to +85 degC
Relative Humidity 95% non-condensing
Protection Rating IP20
Vibration/Shock Resistance Conforms to IEC 68-2-6 / IEC 68-2-27 standards
EMC Immunity / Emission Conforms to EN 50082 (ESD, burst) / EN 50081
Weight 150 g

Installation Guidelines

  • Mounting: Mount horizontally or vertically on standard 35 mm DIN rails (EN 60715). Ensure the locking mechanism clicks securely onto the rail.
  • Shielding: Keep the fieldbus cable shield securely grounded close to the entry point using appropriate shield terminal clamps. Use low-impedance connections for the grounding terminal.
  • Thermal Considerations: Provide at least 30 mm of free ventilation space above and below the BK3110 unit to prevent heat accumulation.
  • Power Supply Wiring: Disconnect all power sources before wiring the power contacts or signal terminals. Use standard industrial-grade copper wire matching current specifications.
Loading product navigation…

What is the maximum data rate supported by the Beckhoff BK3110 coupler?

The BK3110 supports standard PROFIBUS communication rates up to 12 Mbaud, adjusting automatically to match the master controller configuration.

How many digital I/O channels can the BK3110 handle?

The BK3110 can process up to 256 digital inputs and 256 digital outputs across a maximum of 64 modular Bus Terminals.

Is diagnostic software required to set up the BK3110?

Configuration can be fully performed by the system's DP master controller via GSD files, or using the optional Beckhoff KS2000 software package for direct parameters and diagnostics.

What is the maximum power contact current capability of this module?

The integrated power contacts can carry a maximum current of 10 A at voltages up to 24 V DC or AC.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...