1 daripada 1

BECKHOFF BK8000 RS485 Bus Coupler

BECKHOFF BK8000 RS485 Bus Coupler

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: BK8000

  • Negara asal:Jerman

  • Jenis Produk: RS485 Bus Couplers

  • Pembayaran: T/T, Western Union

  • Berat: 170g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for reliable industrial fieldbus integration, the Beckhoff BK8000 Bus Coupler links modular Beckhoff Bus Terminals directly to RS485 network architectures. This interface module processes up to 512 digital input/output channels and 256 analog input/output channels, translating physical peripheral signals into the open, documented RS485 serial communication protocol. System parameters and node addressing are easily set up using the KS2000 configuration software, ensuring seamless commissioning and diagnostics.

The BK8000 acts as the central decentralized head station, managing the internal K-bus system and distributing power to downstream terminal slices. With integrated galvanic isolation separating the fieldbus connection, the internal electronic components, and the 24 V DC power contacts, this bus coupler delivers excellent noise immunity and operational stability in demanding electrical environments.

Features

  • Efficient connection of up to 64 local Beckhoff Bus Terminals to an RS485 fieldbus network.
  • Direct configuration and advanced diagnostic mapping via the KS2000 software interface.
  • Galvanic isolation up to 500 V between power contacts, internal supply voltage, and the fieldbus interface.
  • Integrated power supply terminal designed to supply the internal K-bus with up to 1750 mA.
  • Support for standard serial transfer media via screened, twisted-pair copper cabling.

Applications

  • Industrial process automation and distributed control systems (DCS).
  • HVAC and building automation networks utilizing RS485 multidrop configurations.
  • Machine building and production lines requiring decentralized input/output blocks.
  • Energy management and remote telemetry systems.

Technical Specifications

Manufacturer BECKHOFF
Model / Part Number BK8000
Protocol Open, documented protocol
Bus Interface RS485 D-sub
Data Transfer Rates 9.6 kbaud, 19.2 kbaud, 38.4 kbaud
Max. Number of Bus Terminals 64
Max. Number of Fieldbus Bytes 512 byte input / 512 byte output
Digital Peripheral Signals 512 inputs / outputs
Analog Peripheral Signals 256 inputs / outputs
Power Supply 24 V DC (-15 % / +20 %)
Input Current 70 mA + (total K-bus current) / 4 (Max. 500 mA)
Starting Current 2.5 x continuous current
Recommended Fuse ≤ 10 A
K-Bus Current Supply 1750 mA
Power Contacts Max. 24 V DC / Max. 10 A
Electrical Isolation 500 V (power contact / supply voltage / fieldbus)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Weight Approx. 170 g

Installation Guidelines

  • Mounting: Install on standard 35 mm DIN rail (EN 60715) in a clean, dry control cabinet. The installation position is variable, but vertical alignment is recommended for optimal convection cooling.
  • Wiring: Always use shielded, twisted-pair copper cables (recommended cross-section: 2 x 0.25 mm²) for the RS485 communication line to prevent electromagnetic interference.
  • Grounding: Ensure the DIN rail and the PE (protective earth) connection points are bonded to a low-impedance ground plane.
  • K-bus Protection: Ensure the total current consumption of connected Bus Terminals does not exceed the maximum K-bus current supply of 1750 mA. Install a power feed terminal if current requirements exceed this limit.

Compliance and Certifications

  • CE: Yes
  • UL: Yes
  • ATEX Markings: II 3 G Ex ec IIC T4 Gc
  • IECEx Markings: Ex ec IIC T4 Gc
  • Marine Approval: DNV GL
Loading product navigation…

What is the maximum number of Bus Terminals that can be connected to the BK8000?

The BK8000 RS485 Bus Coupler supports up to 64 local Bus Terminals.

How is the Beckhoff BK8000 configured?

Configuration and diagnostic parameterization are performed using the Beckhoff KS2000 software tool.

What data transfer rates does the BK8000 support?

The module supports data transfer rates of 9.6 kbaud, 19.2 kbaud, and 38.4 kbaud.

What is the maximum current capacity supplied to the K-bus?

The BK8000 supplies a maximum internal K-bus current of 1750 mA to power the connected terminal slices.

Is the BK8000 certified for use in hazardous areas?

Yes, the BK8000 carries ATEX (II 3 G Ex ec IIC T4 Gc) and IECEx certifications for Zone 2 hazardous environments.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...