1 daripada 1

Beckhoff CX1030-0112 CX1030 Basic CPU Module

Beckhoff CX1030-0112 CX1030 Basic CPU Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: CX1030-0112

  • Negara asal:Jerman

  • Jenis Produk: CPU Modules

  • Pembayaran: T/T, Western Union

  • Berat: 580g

  • Dimensi: 96 mm x 112 mm x 99 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Industrial automation setups requiring high-performance processing utilize the CX1030-0112 basic CPU module as a central control unit within the Beckhoff Embedded PC system. This module features an Intel Pentium M processor running at 1.8 GHz, delivering considerable computing power for demanding PLC, NC PTP, or NC I motion control applications. Configured with a internal 16-bit ISA (PC/104) system bus, the module maintains robust communication capabilities with adjacent system expansion terminals.

The unit acts as the core controller, relying on compatible CX1100 power supply modules to interface with either E-bus or K-bus I/O terminal systems. Network communications are facilitated via two RJ45 ports connected through an internal switch, enabling simple daisy-chain networking topologies without external switches. To ensure operational stability under high thermal loads, the processor is fitted with an active cooling module consisting of a speed-controlled, double ball bearing fan cartridge that can be easily replaced in the field.

Features

  • Intel Pentium M processor with a clock frequency of 1.8 GHz for high-performance processing.
  • Integrated dual-port RJ45 Ethernet switch (10/100 Mbit/s) for flexible network configurations.
  • Standard Compact Flash Type I and II slot with an integrated eject mechanism for storage expansion.
  • Active, speed-regulated cooling module featuring a field-replaceable fan cartridge with double ball bearings.
  • Diagnostic LEDs on the front panel indicating power status, LAN link/activity, TwinCAT status, and flash access.
  • Integrated battery-backed real-time clock for persistent date and time tracking.

Applications

  • High-speed manufacturing and assembly lines requiring precise PLC and motion control.
  • Complex CNC machines and multi-axis positioning systems using TwinCAT NC I or NC PTP runtimes.
  • Power generation systems and renewable energy monitoring.
  • Process control systems requiring modular E-bus or K-bus I/O integration.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model / Article Number CX1030-0112
Processor Intel Pentium M, 1.8 GHz
Number of Cores 1
Flash Memory Compact Flash slot (128 MB CF card included)
Main Memory 256 MB DDR RAM (expandable ex factory to 1 GB)
Network Interfaces 2 x RJ45 10/100 Mbit/s (internal switch)
System Bus 16-bit ISA (PC/104)
I/O Connection Type Via CX1100 power supply module (E-bus, K-bus, or K-bus/IP-Link)
Diagnostic LEDs 1 x Power, 2 x LAN link/activity, 1 x TC status, 1 x Flash access
Cooling Active cooling module with speed-controlled fan cartridge
Real-Time Clock Internal battery-backed clock (exchangeable battery)
Max. Power Consumption 32 W
Dimensions (W x H x D) 96 mm x 112 mm x 99 mm
Weight approx. 580 g
Operating Temperature 0 to 50 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95 %, non-condensing
Protection Rating IP20

Connections and Interfaces

Interface / Port Function
RJ45 (Port 1 & Port 2) 10/100 Mbit/s Ethernet interface via internal switch
CF Slot Compact Flash Type I + II insert with eject mechanism for OS and user programs
PC/104 Bus 16-bit internal system bus connection for expansion modules

Installation Guidelines

  • Mounting: Mount horizontally on standard 35 mm DIN rail (EN 60715) within a dry, clean industrial enclosure.
  • Power Supply Connection: Ensure a compatible power supply module (CX1100-0012, CX1100-0013, or CX1100-0014) is properly coupled to the system bus on the right side of the unit before powering the system.
  • Ventilation: Maintain sufficient clearance above and below the module to allow unhindered airflow through the cooling fan and heatsink assembly.

Compliance and Certifications

  • CE
  • UL
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 and EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 and EN 60068-2-27
Loading product navigation…

Which power supply modules are compatible with the Beckhoff CX1030-0112?

The CX1030-0112 basic CPU module requires a CX1100 series power supply module, such as the CX1100-0012 (K-bus connection), CX1100-0013 (K-bus and IP-Link), or CX1100-0014 (E-bus connection).

What is the function of the internal dual RJ45 ports on the module?

The two RJ45 ports are connected via an internal switch. This allows for simple line topologies (daisy-chaining) for Fast Ethernet 10/100 Mbit/s networks without needing an external network switch.

How is the cooling system of the CX1030-0112 maintained?

The module uses active cooling featuring a speed-controlled, double ball bearing fan cartridge. The cartridge is designed for high reliability and can be easily replaced in the field if needed.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...