1 daripada 1

Beckhoff CX2040-0140 CX2000 Series Basic CPU Module

Beckhoff CX2040-0140 CX2000 Series Basic CPU Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: CX2040-0140

  • Negara asal:Jerman

  • Jenis Produk: Embedded PC CPU Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 144 mm x 99 mm x 91 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered to handle complex computing operations in demanding automation environments, the Beckhoff CX2040-0140 stands as a high-performance, fan-cooled embedded industrial PC. Driven by an Intel Core i7 quad-core processor operating at 2.1 GHz, this controller offers substantial processing capacity for multi-threaded applications. The unit features built-in high-speed diagnostic capabilities, a dedicated non-volatile memory system, and an exchangeable battery-backed real-time clock. Designed for flexible integration, it natively identifies and manages both E-bus (EtherCAT) and K-bus (standard terminal) communications when connected to a compatible power supply module.

Features

  • High-performance processing with an Intel Core i7 2715QE 2.1 GHz quad-core architecture.
  • Dual Gigabit Ethernet interfaces (RJ45, 10/100/1000 Mbit/s) enabling independent networking configurations.
  • Integrated ball-bearing cooling fan with smart active speed monitoring and diagnostic reporting.
  • Automatic detection and bridging of E-bus (EtherCAT Terminals) and K-bus (Bus Terminals) signals.
  • Onboard 128 kB NOVRAM for reliable, non-volatile variable retention during power loss.
  • Rich external connectivity including four USB 2.0 ports and a dedicated DVI-I video output.

Applications

  • High-speed coordinated motion control and multi-axis PLC operations.
  • Complex data aggregation and gateway communication in large manufacturing systems.
  • HMI visualization and database management running on local Windows environments.
  • Centralized SCADA and telemetry acquisition stations.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Number CX2040-0140
Processor Intel Core i7 2715QE (2.1 GHz, 4 Cores)
Main Memory 4 GB DDR3 RAM (non-expandable)
Persistent Memory 128 kB NOVRAM
Storage Interface CFast flash card slot (20 GB or 40 GB depending on OS)
Network Interfaces 2 x RJ45 10/100/1000 Mbit/s (independent)
USB Ports 4 x USB 2.0
Video Interface 1 x DVI-I
Operating System Windows 10 IoT Enterprise 2016 LTSB
TwinCAT Software No TwinCAT pre-installed (Platform Level: High Performance 70)
Operating Voltage 24 V DC (-15% / +20%)
Power Consumption 32 W (Maximum)
Protection Rating IP20
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Physical Dimensions 144 mm x 99 mm x 91 mm
Unit Weight 1230 g (approx. 1.23 kg)
Shipping Weight (Calculated) 3.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The CX2040-0140 module is supplied from the factory without runtime TwinCAT control licenses (Control software: No TwinCAT). To deploy as a real-time machine controller, appropriate licenses for TwinCAT 3 (Platform Level 70 - High Performance) must be acquired and installed. It physically and logically replaces standard low-power CX modules, but requires the installation of a matching CX2100 series power supply unit to activate the physical K-bus/E-bus backplane.

Application Pitfalls & Engineering Notes

Unlike low-power Intel Atom variants, the 2.1 GHz quad-core Intel Core i7 processor within the CX2040-0140 relies actively on its integrated ball-bearing fan. If the cooling assembly gets restricted or fails, thermal throttling will occur. System monitoring logic should continuously read the integrated diagnostic LED register and fan-speed monitoring flags to trigger a controlled shutdown before critical safety cutoffs are reached inside closed enclosures with ambient temperatures approaching 60 degC.

Commissioning & Wiring Tips

When connecting an external operator terminal, always interface your display through the native DVI-I port before powering up the controller. Real-time dynamic display Handshaking occurs during the UEFI boot sequence. To ensure system shielding and noise immunity conform to EN 61000-6-2/EN 61000-6-4, the DIN rail must have an low-impedance connection to the central control panel ground plate.

Installation Guidelines

CRITICAL WARNING:

Disconnect all primary power sources before mounting or disassembling the CX2040-0140 and associated I/O modules. Failure to fully de-energize the assembly can cause permanent damage to the internal E-bus contact structures and lead to communication bus faults.

1
Ensure the DIN rail is securely mounted and grounded inside the IP54 rated industrial enclosure.
2
Align the CX2040-0140 with the DIN rail, then push it back until the latches snap into place.
3
Slide the CX2100 power supply module alongside the CPU module until the locking connectors fully engage.
4
Insert an authorized CFast card containing the Windows 10 IoT image into the slot prior to power up.
Loading product navigation…

Does the CX2040-0140 come preloaded with TwinCAT licenses?

No, this specific model (CX2040-0140) is delivered with the Windows 10 IoT Enterprise operating system but without pre-installed TwinCAT runtime software. Users must configure and purchase licenses separately for TwinCAT 3 (Platform Level 70).

Can I upgrade the system memory (RAM) in this module?

No, the 4 GB DDR3 RAM is integrated directly onto the motherboard CPU architecture and is non-expandable.

Does the unit support both K-bus and E-bus terminals?

Yes, when coupled with the appropriate CX2100-series power supply module, the CX2040-0140 features automatic recognition to interface natively with either E-bus (EtherCAT) or K-bus (standard) terminal lines.

What is the purpose of the integrated 128 kB NOVRAM?

The integrated 128 kB NOVRAM functions as reliable non-volatile memory to safely store process variables and critical system states during unplanned power outages without requiring a UPS.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...