1 daripada 1

Beckhoff CX2550-0279 CX2000 Series USB Extender 2.0 Transmitter Module

Beckhoff CX2550-0279 CX2000 Series USB Extender 2.0 Transmitter Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: CX2550-0279

  • Negara asal:Jerman

  • Jenis Produk: USB Extender Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 24 mm x 99 mm x 54.5 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The Beckhoff CX2550-0279 functions as a direct system-bus expansion module designed for CX20xx Embedded PCs, enabling remote USB 2.0 signal transmission up to 50 meters. This transmitter module mounts directly to the left-hand side of a CX20xx CPU block, converting standard internal USB lines into a serialized differential signal suitable for long-distance runs over standard Ethernet-style physical media. This setup is specifically optimized for connecting control panels such as the CP29xx-0000 series without signal degradation or latency spikes, ensuring seamless peripheral integration in complex industrial environments.

Key Features

  • Dedicated 1 x USB Extended 2.0 interface utilizing a rugged RJ45 connection port.
  • Reliable signal extension up to a maximum distance of 50 meters over standard Cat.5E or higher shielded cabling.
  • Native system bus integration drawing power directly through preceding CX2100-0xxx power supply units.
  • On-board LED diagnostic indicators for real-time status validation (Power, Host, Activity, and Link status).
  • Compact 24 mm form factor designed for high-density DIN-rail mounting configurations.

Applications

  • Connecting decentralized HMI and operator screens (CP29xx-0000 series) in scattered manufacturing cells.
  • Extending USB diagnostic interfaces outside enclosed, high-voltage electrical panels.
  • Facilitating clean wiring routing in modern modular production lines and material handling facilities.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff
Model Number CX2550-0279
Interface Type 1 x USB Extended 2.0 (via RJ45 socket)
Maximum Cable Length 50 meters (using Cat.5E cabling)
Power Feed Via system bus (through CX2100-0xxx modules)
LED Diagnostics Power (1x), Host (1x), Activity (1x), Link (1x)
Dimensions (W x H x D) 24 mm x 99 mm x 54.5 mm
Weight Approximately 190 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Port Type Connector Pinout / LED Signal Description
RJ45 Output Port Pins 1 to 8 Differential USB transmission pairs over Cat.5E shielded line. Do not connect to Ethernet switches.
LED: PWR On (Green) Internal system power is successfully applied via the system bus.
LED: HOST On (Green) Established connection with the primary CX20xx CPU host interface.
LED: LINK On (Green) Active connection established with the remote CP29xx receiver.

Empirical Engineering Insights

Alternative Models & Compatibility

This module behaves specifically as a Point-to-Point Transmitter (Tx) and must be paired with an appropriate receiver, typically integrated directly into Beckhoff CP29xx-0000 Control Panels or external receiver boxes. It is physically designed to slide and snap into place on the left-side expansion slot of the CX20xx series. Ensure your CPU configuration in TwinCAT recognizes the additional module on the PC-system bus before commissioning.

Application Pitfalls & Engineering Notes

A common error on-site is treating the physical RJ45 interface on the front of this unit as an Ethernet network port. Patching this connection into a standard LAN switch, router, or hub can cause immediate electrical damage to either the network hardware or the internal transceiver circuitry of the controller. Keep the extension path strictly point-to-point.

Commissioning & Wiring Tips

For transmissions reaching near the 50-meter limit, always use high-quality, double-shielded copper cabling (S/FTP Cat.5E or Cat.6). Avoid routing this physical-layer run in close proximity to high-frequency variable frequency drive (VFD) output cables or high-voltage lines, as noise coupling on the differential lines can cause momentary dropouts in panel mouse/keyboard and touch signals.

Installation Guidelines

CRITICAL WARNING: Prior to snapping this expansion unit onto the CX20xx CPU module or altering any interface cables, ensure the entire controller rack and any connected remote displays are completely powered down. Verify that no residual voltages are present in the power supply line. Failure to de-energize can damage sensitive differential transceiver chips on the system bus.
1
Align the male multi-pin system-bus connector of the CX2550-0279 with the left-side female interface of the CX20xx CPU unit. Ensure the DIN-rail locking clips are pulled out.
2
Press the module firmly into place until you hear it click, securing it to the adjacent CPU module. Push the DIN-rail locking clips back in to anchor the module on the DIN rail.
3
Insert your dedicated Cat.5E shielded line into the front RJ45 socket and route directly to the panel receiver module, keeping it separate from high-interference power lines.
Loading product navigation…

Can I connect this transmitter directly to a standard network switch or router?

No. The RJ45 interface uses a specialized proprietary physical layer to transmit differential USB signals. Connecting this port to an Ethernet switch or network device can damage the internal components of both units.

What is the maximum cable length supported by this module?

The module supports point-to-point connections up to a maximum distance of 50 meters. To reach this distance, use high-quality shielded Cat.5E or Cat.6 cabling.

Where does this module receive its operating power?

The device draws its power directly from the system bus connected to the adjacent CPU block, which is powered through standard CX2100-0xxx power supply units.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...