Beckhoff CX5130-0113 CX5100 Series CPU Module

Beckhoff CX5130-0113 CX5100 Series CPU Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: CX5130-0113

  • Negara asal:Jerman

  • Jenis Produk: Embedded PCs

  • Pembayaran: T/T, Western Union

  • Berat: 1095g

  • Dimensi: 142 mm x 100 mm x 92 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for medium-scale automation tasks, the Beckhoff CX5130-0113 represents a high-performance industrial controller within the CX5100 Embedded PC series. This DIN-rail mountable hardware unit features an Intel Atom E3827 dual-core processor operating at 1.75 GHz, providing efficient processing capability combined with low power requirements. The controller acts as a central processing unit capable of managing complex PLC, Motion Control, and visualization systems directly on the DIN rail.

The unit features integrated interfaces including dual Gigabit Ethernet ports, USB 2.0 connections, and a DVI-I display output for local HMI. The CX5130-0113 is built with an automatic bus recognition interface, allowing direct connection to either Beckhoff E-bus (EtherCAT) or K-bus (standard Bus Terminal) I/O systems. An integrated 1-second uninterruptible power supply (UPS) secures up to 1 MB of persistent data on a CFast card to protect critical system variables in the event of a power failure.

Features

  • Equipped with an Intel Atom E3827 dual-core processor (1.75 GHz) for reliable multi-tasking industrial control.
  • Features 4 GB DDR3 RAM as system main memory.
  • Provides independent slots for CFast cards and microSD cards (media not included).
  • Equipped with a hardware-integrated 1-second UPS (saves up to 1 MB of persistent data onto the CFast card).
  • Two independent 10/100/1000 Mbit/s RJ45 Ethernet ports enable network segmentation and optimal communication throughput.
  • Automatic physical bus detection for flexible implementation of E-bus (EtherCAT Terminals) and K-bus (Bus Terminals).
  • Convection cooling architecture design without internal fans for reduced wear and long-term maintenance-free operation.

Applications

  • Centralized control for medium-scale manufacturing machinery and continuous processing lines.
  • Embedded monitoring and data logging in energy distribution networks and power generation plants.
  • Process control and system integration within industrial water and wastewater treatment facilities.
  • Infrastructure automation, including HVAC and environmental control systems in high-availability environments.

Technical Specifications

CategoryTechnical ParameterValue
Manufacturer Beckhoff CX5130-0113
Processor Intel Atom E3827, 1.75 GHz, 2 Cores Intel Atom E3827, 1.75 GHz, 2 Cores
System Memory Main Memory 4 GB DDR3 RAM (not expandable)
Storage Interfaces Flash Memory CFast card slot, microSD card slot
Persistent Storage UPS Function Integrated 1-second UPS (1 MB data storage on CFast card)
Communication Interfaces Network / Peripherals 2 x RJ45 10/100/1000 Mbit/s, 1 x DVI-I, 4 x USB 2.0, 1 x optional interface slot
Diagnostics LED indicators 1 x power, 1 x TC status, 1 x flash access, 2 x bus status
System Clock Internal RTC Battery-backed clock for date and time (exchangeable battery)
Software Platform Operating Systems Windows Embedded Compact 7, Windows Embedded Standard 7 P, Windows 10 IoT Enterprise 2016 LTSB / 2019 LTSC / 2021 LTSC, TwinCAT/BSD
Control Software TwinCAT Support TwinCAT 2 runtime, TwinCAT 3 runtime (XAR)
TwinCAT Platform Platform Level Performance (40)
I/O Connection Bus System Support E-bus (EtherCAT) or K-bus (Bus Terminal), automatic detection
Power Supply Supply Voltage 24 V DC (-15% / +20%)
I/O Current Output E-bus/K-bus Current 2 A
Power Consumption Nominal / Peak Max. 14 W (Max. 20 W with charging UPS)
Physical Dimensions Dimensions (W x H x D) 142 mm x 100 mm x 92 mm
Weight Net Weight Approx. 1095 g
Environmental Limits Operating Temperature -25 degC to +60 degC
Environmental Limits Storage Temperature -40 degC to +85 degC
Environmental Limits Relative Humidity 95%, non-condensing
Protection Class IP Rating IP20
Standards compliance EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Standards compliance Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27

Connections and Interfaces

Interface PortConnector TypeDescription
LAN 1 / LAN 2 RJ45 Dual independent Gigabit Ethernet connections (10/100/1000 Mbit/s)
Video Out DVI-I Allows connection of an analog or digital display/monitor
USB 1 - 4 USB Type-A 4 x USB 2.0 interfaces for input peripherals and storage access
Option Interface Slot Internal extension slot Allows insertion of optional factory-configured communication modules
Power & I/O Terminal block 24 V DC power input terminal and connection interface for I/O modules

Installation Guidelines

  • Mounting: Mount the unit onto standard 35 mm DIN rails (EN 60715) in a vertical position to facilitate natural convective heat dissipation.
  • Ventilation Clearance: Ensure at least 30 mm of free space above and below the device to allow adequate airflow and prevent localized overheating.
  • Wiring: Use flexible cables with appropriate cross-sections for the 24 V DC power connection. Observe polarity designations to prevent damage to the internal power supply module.
  • Grounding: Connect the functional earth terminal securely to the mounting plate or DIN rail to optimize electromagnetic compatibility (EMC) shielding.

Compliance and Certifications

  • CE
  • UL
  • DNV GL
  • With CX2900-0107 ordering option: ATEX, IECEx, cFMus
  • ATEX Marking: II 3 G Ex nA IIC T4 Gc and II 3 D Ex tc IIIC T135 degC Dc
  • IECEx Marking: Ex nA IIC T4 Gc and Ex tc IIIC T135 degC Dc
  • cFMus Marking: Class I, Division 2, Groups A, B, C, D and Class I, Zone 2, AEx ec IIC T4 Gc
Loading product navigation…

Does the Beckhoff CX5130-0113 include flash storage media?

No, storage media (such as CFast or microSD cards) is not included with the CX5130-0113 module. These must be purchased separately depending on your storage capacity and operating system requirements.

What is the purpose of the 1-second UPS on this Embedded PC?

The integrated 1-second UPS provides short-term backup power during a supply failure, allowing the operating system to save up to 1 MB of critical persistent variable data to the CFast card.

Can the 4 GB DDR3 system memory of the CX5130-0113 be upgraded?

No, the 4 GB DDR3 RAM on the Beckhoff CX5130-0113 is integrated directly onto the motherboard and is not expandable.

Does the CX5130-0113 support both K-bus and E-bus terminals?

Yes, the controller features automatic bus system recognition and automatically configures its hardware interface depending on whether EtherCAT (E-bus) or standard Bus Terminals (K-bus) are physically connected to the module.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...