Description

Designed specifically for high-accuracy gravimetric and force monitoring applications, the Beckhoff EL3356-0020 EtherCAT Terminal processes differential signals from full-bridge strain gauges with exceptional speed and precision. This terminal interfaces directly with resistor bridges to deliver reliable, factory-calibrated measurements in industrial process environments.

Key Features

  • Direct interface for one resistor bridge in full-bridge technology.
  • High-resolution 24-bit analog-to-digital conversion with 32-bit data presentation options.
  • Factory calibration certificate stored internally for guaranteed accuracy.
  • Supports Distributed Clocks (DC) for precise temporal synchronization across the EtherCAT network.
  • Integrated dynamic filters, quadruple averager, and self-calibration routines.

Industrial Applications

  • High-precision industrial platform scales and vessel weighing.
  • Material testing machines and tensile strength evaluation systems.
  • Silo and hopper level measurements with dynamic load distribution.
  • Torque and force monitoring on rotating equipment.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Number EL3356-0020
Product Type EtherCAT Terminal
Number of Inputs 2, for 1 full-bridge resistor bridge
Technology Type Resistor bridge, strain gauge
Signal Type Differential
Distributed Clocks Yes
Measuring Range UD Max. -25 to +25 mV rated voltage
Measuring Range UREF Max. -12 to +12 V rated voltage
Internal Resistance > 200 kOhm (UREF), > 1 MOhm (UD)
Input Filter Limit 10 kHz low pass (-3 dB)
Conversion Time 0.1 to 250 ms (configurable)
Resolution 24 bit (32 bit presentation)
Measurement Error < +/-0.01 % of calculated load value
E-bus Current Draw Typ. 280 mA
Calibration Type Factory calibrated (with certificate)
Operating Temperature 0 to +55 degC
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Connection Technology Spring-actuated cage clamp
Wire Cross Section Solid/Stranded: 0.08 - 2.5 mm2 (AWG 28 - 14)
Shipping Weight 2.0 kg

Alternative Models & Compatibility

Comparing the EL3356-0020 to standard EL3356 terminals, the primary differentiator is the included factory calibration certificate stored directly within the terminal's internal non-volatile memory. To maintain compatibility with TwinCAT projects, ensure the corresponding EtherCAT XML Device Description (ESI) file matches this precise hardware revision to prevent E-bus initialization failures.

Application Pitfalls & Engineering Notes

When deploying inside high-density control panels, thermal fluctuations can degrade calibration accuracy. While the active self-calibration routine corrects for gain and offset drift, mounting the terminal away from high-heat components like variable frequency drives is recommended. Additionally, aggressive setting of dynamic filters (CoE 0x8000) may introduce signal delays that can affect high-speed check-weighing applications.

Commissioning & Wiring Tips

Shielding is critical when dealing with microvolt-level differential signals (UD). Run strain gauge cabling through dedicated conduits and terminate the overall shield directly to the grounded DIN rail via low-impedance grounding clamps. Ensure CoE parameters (such as the notch filter for 50 Hz/60 Hz noise rejection) are aligned with your localized grid frequency to maximize signal stability.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Ensure the main power supply and E-bus system are entirely de-energized before mounting, wiring, or removing this terminal. Failure to do so can result in electrical shock, transient surges on the bus, or permanent damage to the high-precision differential circuit of the measuring module.

1 Position the terminal on the standard 35 mm DIN rail (conforming to EN 60715) and slide it until the locking clip securely snaps into place.
2 Ensure reliable grounding of the DIN rail to establish a noise-free return path for the high-precision analog signals.
3 Strip wires to the recommended length of 8 to 9 mm. Insert a flathead screwdriver into the spring actuation slot to open the cage clamp, insert the wire, and release the screwdriver.
4 Configure the TwinCAT System Manager to recognize the new device, and verify calibration parameter integration via CoE online indices.
Loading product navigation…

What is the primary difference between the EL3356-0020 and standard EL3356 terminals?

The EL3356-0020 variant features factory calibration directly stored in the terminal's internal EEPROM, providing a certified measurement error of less than 0.01 percent under nominal conditions.

Does the EL3356-0020 support Distributed Clocks (DC)?

Yes, this EtherCAT terminal supports Distributed Clocks, enabling synchronized, high-precision signal acquisition across multi-axis or distributed measurement systems.

How should shield grounding be handled to minimize noise in microvolt readings?

Connect the strain gauge cable shield directly to the terminal's designated shield contacts, ensuring a low-impedance connection to the DIN rail's earth ground to prevent electromagnetic interference from distorting the differential signal.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...