Designed for direct connection of thermocouples located in hazardous areas classified Zone 0/20, the Beckhoff ELX3314 processes four high-precision differential analog signals within an intrinsically safe Ex i EtherCAT architecture. This module enables direct temperature measurement from field sensors in explosive atmospheres without requiring additional external safety barriers, optimizing cabinet space and system integration.

Key Features

  • Intrinsically Safe (Ex i) Interfaces: Certified for direct connection to sensors located in Zone 0/20, Zone 1/21, and Zone 2/22 hazardous areas.
  • Multi-Thermocouple Support: Compatible with thermocouple types K, J, L, E, T, N, U, B, R, S, and C (Type K set as default).
  • High-Resolution Digitization: 16-bit analog-to-digital conversion delivering 0.1 degC per digit resolution.
  • Onboard Signal Processing: Integrated limit value monitoring, digital filtering, and sensor characteristic curve linearization.
  • Compact Form Factor: 12 mm housing width with integrated status LEDs for channel diagnostics and run/error states.

Industrial Applications

  • Chemical & Petrochemical Processing: Temperature monitoring of reactors, distillation columns, and storage vessels in hazardous zones.
  • Oil & Gas Refining: Thermal profiling of pipelines, extraction units, and processing facilities.
  • Pharmaceutical Manufacturing: High-precision temperature control in sterile, explosive solvent environments.
  • Combustion & Furnace Control: Direct exhaust gas and burner temperature measurement in hazardous industrial environments.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model / SKU ELX3314
Number of Inputs 4 (differential)
Connection Method 2-wire
Measuring Range Sensor dependent (e.g., Type K: -270 to +1370 degC); Voltage: ±30 to ±75 mV
Resolution 0.1 degC per digit (16-bit)
Measuring Error < ±0.3% (relative to full scale value)
Internal Resistance typ. ≥ 10 kOhm (differential)
Input Filter Limit Frequency typ. 1 kHz (dependent on sensor length, conversion time, and sensor type)
Conversion Time 10 to 5000 ms (adjustable, default: 310 ms)
Supply Voltage Electronics 24 V DC (via power contacts, requires ELX9560 power supply)
Current Consumption Power Contacts typ. 10 mA
Current Consumption E-bus typ. 70 mA
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Housing Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight 60 g
Shipping Weight 2.00 kg

Wiring & Connection Specifications

Conductor Type Cross-Section (Metric) Cross-Section (AWG)
Solid Wire (s) 0.08 to 2.5 mm² AWG 28 to 14
Stranded Wire (st) 0.08 to 2.5 mm² AWG 28 to 14
Flexible Wire with Ferrule (f) 0.14 to 1.5 mm² AWG 26 to 16
Stripping Length 8 to 9 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The ELX3314 requires the ELX9560 power supply terminal to feed the power contacts with the necessary intrinsically safe isolation. It cannot be mixed directly with standard non-Ex EL series terminals without the appropriate ELX9560 isolation barrier separating the power rails on the DIN rail assembly.

Application Pitfalls & Engineering Notes

When designing the physical layout, ensure the total current consumption on the E-bus (70 mA) and power contacts (10 mA) does not exceed the maximum output current of the upstream ELX9560 power supply terminal. Maintain strict physical separation between intrinsically safe (Ex i) field wiring and non-intrinsically safe wiring in the control cabinet.

Commissioning & Wiring Tips

Use shielded thermocouple extension wire and ground the shield at the entry point of the control cabinet. Configure the specific thermocouple type and conversion time (10 to 5000 ms) within TwinCAT System Manager to optimize noise rejection (default conversion time is 310 ms).

Installation Guidelines

CRITICAL WARNING: HAZARDOUS AREA SAFETY

De-energize the entire system before installing, removing, or wiring any ELX series terminal. Ensure compliance with local explosion protection regulations (EN 60079-14) and verify that the Ex i parameters of the connected thermocouple match the safety values of the ELX3314.

1

Mount the ELX9560 power supply terminal onto the 35 mm DIN rail (conforming to EN 60715) to establish the Ex i power segment.

2

Slide the ELX3314 terminal onto the DIN rail to the right of the power supply, ensuring the double slot and key connection locks securely with the adjacent module.

3

Strip the thermocouple field wires to 8–9 mm. Insert a flat-blade screwdriver into the spring release slot, insert the wire, and release to secure the connection.

4

Connect the EtherCAT network, apply 24 V DC power to the ELX9560, and verify that the run LED on the ELX3314 turns green.

Loading product navigation…

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...