Designed for decentralized automation tasks in harsh environments, the Beckhoff EP2816-0004 is a high-density digital output module that interfaces directly with the EtherCAT network. This fieldbus-level device features 16 digital channels packaged in a compact, IP67-rated housing. It is engineered to switch binary control signals from the automation controller to actuators, solenoids, or indicators on the machine. By utilizing an M16, 19-pin output connector, the EP2816-0004 provides a centralized wiring point, making it highly compatible with multi-pin connector valve terminals.

The module operates on a nominal 24 V DC control voltage and handles up to 0.5 A per output channel. Each channel is designed with individual short-circuit protection to protect local wiring and system backplanes from overcurrent faults. With integrated support for Distributed Clocks, this EtherCAT Box guarantees highly synchronized signal processing across industrial installations.

Features

  • 16 digital output channels in a robust, space-saving design.
  • Centralized M16 19-pin output connector, optimizing connection to multi-pin valve manifolds.
  • Short-circuit proof outputs rated at 0.5 A per channel (total sum current of 4 A).
  • High-speed switching times with a typical turn-on time of 25 us and turn-off time of 50 us.
  • Distributed Clocks integration ensures precise synchronization with the central PLC controller.
  • Rugged IP65/66/67 construction enables direct machine mounting without an electrical enclosure.

Applications

  • Pneumatic valve terminal integration in industrial packaging lines.
  • Decentralized control of solenoids and actuators in automotive assembly.
  • On-machine I/O distribution for manufacturing machinery with limited enclosure space.
  • Water treatment facilities and process control operations requiring high environmental resistance.

Technical Specifications

ManufacturerPart Number / ModelProtocolBus InterfaceNumber of OutputsOutput ConnectionsLoad TypeNominal Output VoltageMax. Output CurrentSwitching TimesShort-Circuit CurrentDistributed ClocksCurrent Consumption from USAuxiliary Power CurrentPower Supply ConnectionElectrical IsolationOperating TemperatureStorage TemperatureVibration / Shock ResistanceEMC Immunity / EmissionProtection RatingWeight
Beckhoff
EP2816-0004
EtherCAT
2 x M8 socket, shielded, screw type
16
M16 socket, 19-pin
Ohmic, inductive, lamp load
24 V DC (-15% / +20%)
0.5 A per channel (individually short-circuit proof), sum max. 4 A
typ. T_ON: 25 us, typ. T_OFF: 50 us
max. 1.5 A
Yes
120 mA
typ. 20 mA + load
Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
500 V
-25 to +60 degC
-40 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP65 / IP66 / IP67 (conforms to EN 60529)
approx. 165 g

Connections and Interfaces

Interface Type Connector Style Function
EtherCAT Bus 2 x M8 socket, shielded Inbound and outbound industrial Ethernet communications
Digital Outputs 1 x M16, 19-pin socket Unified connection for 16 digital control channels
Power Feed 1 x M8 male socket, 4-pin Primary 24 V DC supply input (US/UP)
Power Downstream 1 x M8 female socket, 4-pin Power pass-through to daisy-chained EtherCAT Box modules

Installation Guidelines

  • Mount the module directly to the machine frame or mounting plate using appropriate M3 screws. Ensure the mounting surface is flat to prevent mechanical stress on the housing.
  • To maintain the IP67 protection rating, ensure all unused M8 and M16 connectors are sealed with corresponding protective caps.
  • Establish a reliable ground connection via the metal mounting surface or the functional earth connection point on the module.
  • Observe the maximum allowable sum current of 4 A across all 16 channels to prevent internal power path overload.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the primary benefit of the M16 19-pin connection on the EP2816-0004?

The M16 19-pin connection consolidates all 16 digital output channels into a single physical interface. This layout is ideal for wiring directly to multi-pin connector valve terminals, minimizing individual cable routing and labor.

What is the total maximum output current supported by the EP2816-0004?

While each individual channel can drive up to 0.5 A, the total sum current across all 16 channels must not exceed 4 A.

Does the EP2816-0004 support precise synchronization across an EtherCAT network?

Yes, this module supports Distributed Clocks, ensuring highly synchronized signal switching matching the requirements of precise automation systems.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...